Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A preliminary study was conducted using electronic portal imaging device (EPID) based dose verification in pre-treatment and in vivo dose reconstruction modes for breast cancer intensity-modulated radiation therapy (IMRT) technique with known repositioning set-up errors. For 43 IMRT plans, the set-up errors were determined from 43 sets of EPID images and 258 sets of cone beam computed tomography images. In-house developed Edose software was used to reconstruct the dose distribution using the pre-treatment and on-treatment (in vivo) EPID acquired fluence maps. The maximum setup error was < 3.5 mm. For 43 pre-treatment cases, the γ pass rate (3 %/3 mm) is 98.49 % ± 1.15 %. The chest wall target ΔV, ΔV, andΔV are all < 5 %, while the majority of the ipsilateral lung ΔV, ΔV, and ΔV are also < 5 %. For 258 in vivo cases, the γ pass rate is 90.98 % ± 6.53 %, with the chest wall target ΔV and ipsilateral lung ΔV both < 5 %, while the other volume differences all exceed 5 %. The γ pass rate for in vivo verification is significantly lower than pre-treatment values. Although the in vivo γ verification satisfies the medical physics requirements, the reconstructed coverage of the chest wall target is far below the clinical dosimetry requirements. In vivo 3D dose reconstruction directly predicts changes in the planning target volume to aid clinicians better understand the actual dose received by patients with intra-fractional motion and anatomical changes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2024.104884DOI Listing

Publication Analysis

Top Keywords

dose reconstruction
8
vivo dose
8
dose verification
8
breast cancer
8
cancer intensity-modulated
8
intensity-modulated radiation
8
radiation therapy
8
set-up errors
8
dose
5
preliminary application
4

Similar Publications

Purpose: This study aimed to evaluate whether low-dose CT imaging using an Sn filter can provide image quality sufficient for the differential diagnosis of cranial deformities in infants while maintaining an effective dose comparable to that of conventional radiography.

Methods: We calculated the effective dose for both head X-ray imaging and low-dose CT with an Sn filter. Phantom images acquired using a CT scanner equipped with an Sn filter were evaluated for bone suture visibility at various conditions (from 10 mAs to 50 mAs, every 10 mAs) using a 4-point visual grading scale.

View Article and Find Full Text PDF

Purpose: Urinary toxicity following radical prostatectomy (RP) and postoperative radiotherapy (RT) includes urinary incontinence and vesicourethral anastomosis (VUA) strictures. With the increasing use of stereotactic body radiotherapy (SBRT), dose-escalation, and reirradiation within the prostate bed (PB), standardization of the definition of urinary organs at risk (OARs) in the post-RP setting is needed. This works aims to provide a comprehensive review of the anatomical and physiopathological changes occurring after RP, as well as to provide a consensus on urinary OARs delineation for prostate cancer (PCa) EBRT in the post-RP setting.

View Article and Find Full Text PDF

Optimization of carotid CT angiography image quality with deep learning image reconstruction with high setting (DLIR-H) algorithm under ultra-low radiation and contrast agent conditions.

Radiography (Lond)

September 2025

Department of Radiology, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, 221002, China; School of Medical Imaging, Xuzhou Medical University, Xuzhou, Jiangsu, 221002, China; Jiangsu Provincial Engineering Research Center for Medical Imaging and Digital Medicine, Xuzhou, Jiangs

Introduction: Carotid artery disease is a major cause of stroke and is frequently evaluated using Carotid CT Angiography (CTA). However, the associated radiation exposure and contrast agent use raise concerns, particularly for high-risk patients. Recent advances in Deep Learning Image Reconstruction (DLIR) offer new potential to enhance image quality under low-dose conditions.

View Article and Find Full Text PDF

Background: The practice of systemic antibiotic prophylaxis to prevent surgical site infection (SSI) in breast surgery remains debated. The aim of this review is to provide a comprehensive overview of the literature evaluating the current evidence on the efficacy of antibiotic prophylaxis in nononcologic breast surgery, including risk-reducing mastectomy, gender-affirming mastectomy, augmentation, and reduction.

Methods: A literature search of PubMed and Cochrane databases of 1990-2025 was conducted to identify studies evaluating antibiotic prophylaxis and SSI outcomes in nononcologic breast surgery.

View Article and Find Full Text PDF

Understanding the transmission routes of high-pathogenicity avian influenza (HPAI) is crucial for developing effective control measures to prevent its spread. In this context, windborne transmission, the idea that the virus could travel through the air over considerable distances, is a contentious concept, and documented cases have been rare. Here, though, we provide genetic evidence supporting the feasibility of windborne transmission.

View Article and Find Full Text PDF