98%
921
2 minutes
20
Background: Accurate histological analysis is crucial for confirming intracerebral neoplasia due to the diverse array of potential diagnoses presented by imaging. In the realm of biopsy techniques, the use of robot-based systems is on the rise, primarily owing to their heightened targeting accuracy. The objective of this study was to elucidate the practicality, learning curve and workflow associated with robot-guided biopsies upon their introduction to a neurosurgical centre.
Materials And Methods: In March 2022, the neurosurgical department at our institution adopted the Medtronic Stealth AutoGuide™ cranial robotic guidance platform, a miniaturized robotic guidance device designed for stereotactic procedures. Four experienced neurosurgeons underwent training with the Stealth AutoGuide™ system, after which 51 consecutive biopsies were performed. The evaluation encompassed entry and target accuracy, preoperative setup time, time required for the biopsy procedure, and overall operating time. Statistical analysis was conducted to identify any differences between the initial 26 and subsequent sets of 25 patients, with the aim of identifying changes in workflow.
Results: The study included all patients necessitating a diagnostic biopsy for intracerebral tumours, with only one patient excluded due to the inaccessibility of the intended target point caused by tumour calcification. Notably, there were no significant differences between the first 25 and last 26 patients in the median time from incision to the first biopsy (overall: 11.5 min, IQR 9.03-15.0), the procedure time (overall: 30.0 min, IQR 23.5-46.5), median accuracy at entry (overall: 2.05 mm, IQR 0.8-3.8), or target point (overall: 2.2 mm (IQR 1.6-3.7). However, a significant reduction in robot setup time was observed between the two groups, median 2.69 min versus 1.17 min, respectively (p ≤ 0.001).
Conclusion: The deployment of the robotic biopsy system, Stealth AutoGuide™, showed high feasibility, steep learning curve due to uncomplicated technical handling using our standardized operative workflow. Therefore, even in prone position a high diagnostic yield was achieved. Overall, the Stealth AutoGuide™ system facilitated biopsies in traditionally challenging regions with concise procedure time and surgeon-independent high accuracy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11685092 | PMC |
http://dx.doi.org/10.3389/frobt.2024.1437568 | DOI Listing |
Natl Sci Rev
September 2025
Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, Suzhou 215123, China.
Chimeric antigen receptor T (CAR-T)-cell therapy is a promising resolution for solid tumors, but its corresponding clinical translation has been hindered by unsatisfactory therapeutic potency and severe cytokine release syndrome. Herein, tetracycline (Tet)-On inducible human epidermal growth factor receptor 1 (HER1)-targeted CAR-T (Tet-HER1-CAR-T) cells were engineered to enable spatially selective activation at tumor sites by doxycycline (Doxy), which is delivered by pH-responsive stealth liposomal calcium carbonate nanoparticles (Doxy@CaCO-PEG). Compared with the intravenous administration of conventional HER1-CAR-T cells and Tet-HER1-CAR-T cells activated by free Doxy, concurrent intravenous administration of Tet-HER1-CAR-T cells and Doxy@CaCO-PEG leads to the localized tumor activation of Tet-HER1-CAR-T cells and reduced systemic secretion of inflammatory cytokines.
View Article and Find Full Text PDFAdv Pharm Bull
July 2025
Department of Pharmaceutics, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education, Manipal 576104, India.
Lipid nanocapsules (LNCs) are an emerging nanocarrier platform for cancer therapy as they can co-deliver multiple drugs, promote synergistic action, and provide targeted drug delivery. The phase inversion temperature (PIT) process is most used for LNC formulation, which has the advantage of process simplicity, thermodynamic stability, and the employment of non-toxic solvents without requiring high energy input. Surface functionalization with targeting ligands like folic acid and peptides increases tumor specificity and reduces off-target toxicity.
View Article and Find Full Text PDFBr J Ophthalmol
September 2025
Department of Ophthalmology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
Background: Persistent full-thickness macular holes (FTMHs) following primary surgery represent a therapeutic challenge. Various surgical treatment approaches have been proposed. This study evaluates anatomical and functional outcomes of a temporary silicone oil tamponade in persistent FTMH in a larger cohort.
View Article and Find Full Text PDFACS Appl Mater Interfaces
September 2025
Department of Mechanical & Industrial Engineering, Louisiana State University, Baton Rouge, Louisiana 70803, United States.
With the rapid advancement in autonomous vehicles, 5G and future 6G communications, medical imaging, spacecraft, and stealth fighter jets, the frequency range of electromagnetic waves continues to expand, making electromagnetic interference (EMI) shielding a critical challenge for ensuring the safe operation of equipment. Although some existing EMI shielding materials offer lightweight construction, high strength, and effective shielding, they struggle to efficiently absorb broadband electromagnetic waves and mitigate dimensional instability and thermal stress caused by temperature fluctuations. These limitations significantly reduce their service life and restrict their practical applications.
View Article and Find Full Text PDFAm J Ophthalmol
September 2025
Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA. Electronic address:
Purpose: To report on the real-world experience of using intravitreal pegcetacoplan for the treatment of geographic atrophy (GA) in age-related macular degeneration (AMD).
Design: Retrospective interventional case series.
Methods: Eyes with symptomatic GA secondary to AMD were treated with 15mg of intravitreal pegcetacoplan and participated in an ongoing prospective swept-source optical coherence tomography angiography (SS-OCTA) imaging study.