Article Abstract

: To determine the impact of corneal and biometry parameters on the normative root mean square (RMS) values of corneal aberrations measured at a 6 mm diameter. : The RMS values for corneal aberrations (anterior, posterior, and total) were measured along with corneal parameters using Scheimpflug tomography on 770 normal subjects. The biometric parameters were measured with an optical biometer. A multiple linear regression model was used to assess the effect of these parameters on the RMS values for corneal aberrations. : The mean RMS values for low-order (LOAs) and high-order 6 mm aberrations (HOAs) were 1.883 ± 0.797 µm and 0.484 ± 0.173 µm, respectively, and for the anterior and posterior cornea, the values were 0.775 ± 0.166 µm and 0.189 ± 0.036 µm, respectively. For the anterior cornea, the main predictors of the RMS LOAs (R = 69.8%) were anterior corneal astigmatism (ACA) and anterior corneal elevation (Ele F) on the apex (both < 0.0001) and for the RMS HOAs (R = 33.3%) the main predictors were age, ACA, and Ele F on the thinnest point (all < 0.0001). For the posterior cornea, considering only the posterior corneal variables, the main predictors of the RMS LOAs (R = 63.4%) were posterior corneal astigmatism and posterior corneal elevation (Ele B) on the thinnest point and apex (all < 0.0001) and for the RMS HOAs (R = 46%) the main predictors were the mean posterior keratometry and Ele B on the thinnest point and apex (all < 0.0001). : Normative data of RMS values for corneal aberrations measured over 6 mm are influenced by age and several corneal parameters, which should be considered when evaluating the diagnostic ability of the RMS values.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11642347PMC
http://dx.doi.org/10.3390/jcm13237125DOI Listing

Publication Analysis

Top Keywords

rms values
24
corneal aberrations
20
values corneal
16
main predictors
16
corneal
14
aberrations measured
12
apex 00001
12
ele thinnest
12
thinnest point
12
posterior corneal
12

Similar Publications

Fault identification for rolling bearing based on ITD-ILBP-Hankel matrix.

ISA Trans

August 2025

School of Automation, Shenyang Aerospace University, Shenyang, Liaoning Province 110136, China. Electronic address:

When a failure occurs in bearings, vibration signals are characterized by strong non-stationarity and nonlinearity. Therefore, it is difficult to sufficiently dig fault features. 1D local binary pattern (1D-LBP) has the advantageous feature to effectively extract local information of signals.

View Article and Find Full Text PDF

Objective: To evaluate the impact of occlusion type and artificial intelligence-based computer-aided design (CAD) software on the geometric accuracy and clinical quality of auto-generated anterior and posterior crown designs.

Methods: Five typodont models representing various occlusion types (normal, Class I anterior diastema, Class II division 1, Class II division 2, and Class III anterior crossbite occlusion) underwent crown preparation for the maxillary right central incisor and first molar. Ten sets of intraoral scans were obtained from each prepared model, and crown designs were automatically generated using two software programs: deep learning-based (DL; Dentbird) and conventional automated (CA; Auto Workflow, 3Shape) (n = 10).

View Article and Find Full Text PDF

Background: Fat volume fraction (FVF) is an important biomarker for non-alcoholic fatty liver disease. However, current CT-based FVF quantification methods lack sufficient accuracy, particularly at lower FVF values.

Purpose: We aimed to analyze the relationship between FVF and Hounsfield units (HU) in unenhanced fatty lesions and identify optimal settings to minimize FVF quantification errors by comparing virtual monochromatic imaging (VMI) from dual-energy CT (DECT) with single-energy CT (SECT) across different patient sizes.

View Article and Find Full Text PDF

Efficient MLC quality assurance using a virtual picket fence test in an MR-Linac.

J Appl Clin Med Phys

September 2025

Medical Physics Division, Department of Medical Innovation & Technology, CUHK Medical Centre, Hong Kong SAR, China.

Background: The Elekta Unity MR-Linac system integrates magnetic resonance imaging (MRI) with a linear accelerator (Linac) for adaptive radiation therapy. Traditional quality assurance (QA) methods for multi-leaf collimators (MLCs) face challenges in this system due to the magnetic field and limited field size of electronic portal imaging devices (EPID).

Purpose: This study aims to develop a 'virtual picket fence' test using machine log files to evaluate MLC performance in the Elekta Unity MR-Linac system, providing a more efficient and comprehensive QA method that overcomes the limitations of traditional approaches.

View Article and Find Full Text PDF

Background: Ensuring reference material (RM) commutability is crucial for evaluating measurement traceability in order to standardize laboratory tests. However, commutability assessment is not routinely performed. We assessed whether RMs prepared following CLSI C37-A guidelines could be used without assessing commutability by evaluating their commutability for four lipid measurements using the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and CLSI EP14 protocols.

View Article and Find Full Text PDF