Optimal suturing techniques in patch-bridging reconstruction for massive rotator cuff tears: A finite element analysis.

Asia Pac J Sports Med Arthrosc Rehabil Technol

Sports Medicine Institute of Fudan University, Department of Sports Medicine, Huashan Hospital, Fudan University, Shanghai, 200040, PR China.

Published: January 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To use a finite element method to construct a patch-bridge repair model for massive rotator cuff tears (MRCTs) and investigate the effects of different suture methods and knot numbers on postoperative biomechanics.

Methods: A finite element model based on intact glenohumeral joint data was used for a biomechanical study. A full-thickness defect and retraction model of the supraspinatus tendon simulated MRCTs. Patch, suture, and anchor models were constructed, and the Marlow method was used to assign the material properties. Three suturing models were established: 1-knot simple, 1-knot mattress, and 2-knot mattress. The ultimate failure load, failure mode, stress distribution of each structure, and other biomechanical results of the different models were calculated and compared.

Results: The ultimate failure load of the 1-knot mattress suture (71.3 N) was 5.6 % greater than that of the 1-knot simple suture (67.5 N), while that (81.5 N) of the 2-knot mattress was 14.3 % greater than that of the 1-knot mattress. The stress distribution on the patch and supraspinatus tendon was concentrated on suture perforation. Failure of the bridging reconstruction mainly occurred at the suture perforation of the patch, and the damage forms included cutting-through and isthmus pull-out.

Conclusion: A finite element model for the patch-bridging reconstruction of MRCTs was established, and patch-bridging restored the mechanical integrity of the rotator cuff. The 2-knot mattress suture was optimal for patch-bridging reconstruction of MRCTs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11635007PMC
http://dx.doi.org/10.1016/j.asmart.2024.10.002DOI Listing

Publication Analysis

Top Keywords

finite element
16
patch-bridging reconstruction
12
rotator cuff
12
1-knot mattress
12
2-knot mattress
12
massive rotator
8
cuff tears
8
element model
8
supraspinatus tendon
8
1-knot simple
8

Similar Publications

Wrist biomechanics remain incompletely understood due to the complexity of experimental measurements in this multi-bone joint system. Finite element analysis provides a powerful alternative for investigating internal variables such as carpal kinematics and displacement patterns. This technical brief compares two bone representation approaches, all-cortical versus cortical-trabecular, using two distinct finite element models developed from the same wrist CT dataset.

View Article and Find Full Text PDF

High cost of clinical trials hinders further enhancement of comprehensive mechanical properties of bioresorbable scaffolds (BRS). Therefore, a multi-objective optimization method combining surrogate modeling and finite element simulation is proposed, based on the evaluation of stents with various auxetic structures and materials. The results demonstrated that re-entrant hexagon stent made of PLA (PLA-RH stent) was a more ideal candidate, with superior radial recoil and force.

View Article and Find Full Text PDF

We have developed a new true triaxial apparatus for rock deformation, featuring six servo-controlled loading rams capable of applying maximum stresses of 220 MPa along the two horizontal axes and 400 MPa along the vertical axis to cubic rock samples of 50 mm side. Samples are introduced into a steel vessel, allowing rock specimens to be subjected to confining pressures of up to 60 MPa. Pore fluid lines connected to two pump intensifiers enable high-precision permeability measurements along all three principal stress directions.

View Article and Find Full Text PDF

In this paper, a single-quartz-enhanced photoacoustic-photothermal dual spectroscopy sensor based on a spherical acoustic resonator (SAR) is reported for the first time. The dual spectroscopy of quartz-enhanced photoacoustic spectroscopy (QEPAS) and quartz-enhanced photothermal spectroscopy (QEPTS), utilizing a single quartz tuning fork (QTF), eliminates the frequency mismatch issue that occurs when multiple QTFs are used. The dual spectroscopy model was constructed using the finite element method, which provides numerical simulation support for subsequent experiments.

View Article and Find Full Text PDF

Differences in the Corneal Biomechanical Responses to LASIK and KLEx Based on Parametric Numerical Simulation.

J Refract Surg

September 2025

From National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, China.

Purpose: To use parametric numerical simulation to characterize and compare the differences in corneal biomechanical responses to laser in situ keratomileusis (LASIK) and keratorefractive lenticule extraction (KLEx) under various surgical settings.

Methods: The Finite Element Model was used in a parametric study to evaluate corneal biomechanical responses to LASIK and KLEx, considering variations in preoperative corneal thickness, corneal flap/cap thickness and diameter, refractive correction, and optical zone diameter. Surgery-induced stress, displacement, and interface contact pressure were compared between LASIK and KLEx using the Wilcoxon signed-rank test.

View Article and Find Full Text PDF