Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Piezoelectric composite materials, combining the advantages of both piezoelectric materials and polymers, have been extensively used in ultrasonic transducers. However, the pitch size of radial array ultrasonic transducers normally exceeds one wavelength, which limits their performance. In order to minimize grating lobes of current radial transducers and then increase their imaging resolution, a 2.5 MHz 1-3 composite radial array transducer with 64 elements and 600 μm pitch was designed and fabricated by combining flexible circuit board and using a bending-and-superposition method. All the array elements were connected and actuated via the customized circuit board which is thin and soft. The kerf size is set to be 1/3 wavelength. PZT-5H/epoxy 1-3 composite was used as an active material because it exhibits an ultrahigh electromechanical coupling coefficient ( = 0.74), a very low mechanical quality factor ( = 11), and relatively low acoustic impedance ( = 13.43 MRayls). The developed radial array transducer exhibited a center frequency of 2.72 MHz, an average -6 dB bandwidth of 36%, an insertion loss of 31.86 dB, and a crosstalk of -26.56 dB between the adjacent elements near the center frequency. These results indicate that the bending-and-superposition method is an effective way to fabricate radial array transducers by binding flexible circuit boards. Furthermore, the utilization of tailored flexible circuitry boards presents an effective approach for realizing reductions in crosstalk level (CTL).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11596718PMC
http://dx.doi.org/10.3390/mi15111363DOI Listing

Publication Analysis

Top Keywords

radial array
20
1-3 composite
12
array transducers
8
ultrasonic transducers
8
array transducer
8
flexible circuit
8
circuit board
8
bending-and-superposition method
8
center frequency
8
array
6

Similar Publications

We experimentally and numerically study the collapse dynamics of a quantum vortex in a two-dimensional atomic superfluid following a fast interaction ramp from repulsion to attraction. We find the conditions and timescales for a superfluid vortex to radially converge into a quasistationary density profile, demonstrating the spontaneous formation of a vortex solitonlike structure in an atomic Bose gas. We record an emergent self-similar dynamics caused by an azimuthal modulational instability, which amplifies initial density perturbations and leads to the eventual splitting of a solitonic ring profile or direct fragmentation of a superfluid into disordered, but roughly circular arrays of Townes solitonlike wave packets.

View Article and Find Full Text PDF

Trapped-ion applications, such as in quantum information processing, precision measurements, optical clocks and mass spectrometry, rely on specialized high-performance ion traps. The last three of these applications typically use traditional machining to customize macroscopic 3D Paul traps, whereas quantum information processing experiments usually rely on photolithographic techniques to miniaturize the traps and meet scalability requirements. Using photolithography, however, it is challenging to fabricate the complex 3D electrode structures required for optimal confinement.

View Article and Find Full Text PDF

As wearable electronics advance, there is a growing need for flexible sensors with high sensitivity to detect even the slightest mechanical stimuli for real-time monitoring across various applications. This study presents a poly-(vinylidene fluoride--trifluoroethylene) (PVDF-TrFE)-based flexible piezoelectric sensor, developed by electrospinning a composite of PVDF-TrFE and barium titanate (BaTiO). The PVDF-TrFE with 3 wt % BaTiO, referred to as PVDF-TrFE (3 wt % BTO), exhibits higher crystallinity, increased β-phase content, and enhanced piezoelectric response, achieving a pressure sensitivity of 0.

View Article and Find Full Text PDF

This study introduces a radial-hierarchical, diffusion-enhanced spatiotemporal sensing paradigm for volatile organic compound (VOC) analysis via an integrated microchamber paper-based chromatomimetic e-nose. The proposed system synergizes interlayer spatiotemporal dynamics with planar spatial variance by employing a radially symmetric electrode array and a hierarchical porous chemoresistive ink (CuP@G). This design leverages molecular diffusion gradients across the sensing plane, enabling precise discrimination of complex VOC mixtures through multidimensional "spatiotemporal fingerprints".

View Article and Find Full Text PDF

Current ultrasound sensors used for wearable blood pressure monitoring typically require driving voltages above 15 V. This study aims to enhance device sensitivity to enable low-voltage operation, thereby reducing power consumption and improving user safety. We propose an ultrathin curved piezoelectric micromachined ultrasonic transducer (PMUT) featuring a 0.

View Article and Find Full Text PDF