98%
921
2 minutes
20
One major systematic error for free-fall atom gravimeters is the effect of two-photon light shift (LS2). In the process of evaluating LS2, the results can be affected by the residual frequency error of direct digital synthesizers due to necessary experimental parameter changes. In this paper, the impact of the coupling effect between the frequency error and LS2 has been investigated and analyzed, along with the related physical mechanisms. The parameters of the frequency error sequence, such as the time step of δt and the time delay of Δt, significantly affect the bias and uncertainty of LS2. Notably, when these parameters are significantly altered or misaligned, the impact can reach several tens of µGal. Conversely, when they remain within the optimal ranges, the impact can be minimal. Specifically, when δt is less than or equal to 10 µs, the impact on the LS2 bias is less than 0.3 µGal, with the contribution to the total uncertainty of the gravity value being approximately 0.1 µGal. Furthermore, after correcting the phase shift introduced by the frequency error, the evaluation results have a similar improvement effect on the whole. Compared to the LS2 theoretical value, the residual is generally on the order of µGal. Through the comprehensive analysis and optimization, as well as related experiments, this cross-effect is managed and decoupled, leading to accurate LS2 evaluation results. This improvement ensures a better accuracy in the obtained absolute gravity values. The analysis methods discussed can provide an effective strategy for enhancing the performance of atom gravimeters.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.535455 | DOI Listing |
Background: Overweight and obesity are major concerns among people living with HIV (PLWH), particularly those on integrase inhibitors, as they elevate the risk of cardiovascular diseases. However, longitudinal data on the burden and risk factors for overweight/obesity in sub-Saharan Africa (SSA) remain limited. This study aimed to estimate the incidence and identify factors associated with overweight and obesity among PLWH who switched to a dolutegravir (DTG)-based ART regimen at Livingstone University Teaching Hospital.
View Article and Find Full Text PDFIEEE Trans Image Process
September 2025
3D imaging based on phase-shifting structured light is widely used in industrial measurement due to its non-contact nature. However, it typically requires a large number of additional images (multi-frequency heterodyne (M-FH) method) or introduces intensity features that compromise accuracy (space domain modulation phase-shifting (SDM-PS) method) for phase unwrapping, and it remains sensitive to motion. To overcome these issues, this article proposes a nonlinear phase coding-based stereo phase unwrapping (NPC-SPU) method that requires no additional patterns while maintaining measurement accuracy.
View Article and Find Full Text PDFThis study aims to tackle the tracking control problem of multiple unmanned surface vessels (USVs). It considers the impact of connectivity-hybrid cyber-attacks in the networked level, and wave-induced disturbances, as well as severe and nonsevere unified modeling rudder angle faults in the physical level. To do this, the study establishes USV models, taking into account actuator fault and cyber-attack modeling.
View Article and Find Full Text PDFTransl Vis Sci Technol
September 2025
State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, People's Republic of China.
Purpose: The purpose of this study was to estimate the correlations between macular optical coherence tomography (OCT)-derived metrics and incident glaucoma risk in myopic eyes.
Methods: This longitudinal observational study included 24,181 individuals with myopia (spherical equivalence [SE] ≤ -0.5 diopters [D]) from the UK Biobank study.
Glob J Qual Saf Healthc
August 2025
Postgraduate Program in Anesthesiology, Surgical Sciences, and Perioperative Medicine, Faculdade de Medicina FMUSP, Universidade de São Paulo, São Paulo, SP, Brazil.
Introduction: As healthcare organizations strive to improve the quality and safety of their services, there is growing recognition of the importance of fostering a patient safety culture to enhance patient safety and improve patient care outcomes. This study aims to evaluate healthcare professionals' perceptions of patient safety culture in accredited vs nonaccredited hospitals within a network of 68 hospitals in Brazil.
Methods: This cross-sectional, multicenter study included 68 hospitals from a private network.