Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Although virtual reality (VR) simulators have demonstrated their efficiency for basic technical skill training of healthcare professionals, validation for more complex and sequential procedures, especially in arthroscopic surgery, is still warranted. We hypothesized that the VR-based training simulation improves arthroscopic cuff repair skills when transferred to realistic visual and haptic conditions.

Hypothesis: VR-based training simulation improves arthroscopic cuff repair skills when transferred to realistic visual and haptic conditions.

Study Design: This study is prospective, multicentric and randomized.

Methods: Thirty orthopedic surgery residents were enrolled in the study and randomized in two groups: VR training (VR+) and no VR training (VR-). Only the VR+ group underwent a monthly VR-based training program for rotator cuff repair. The 1-h VR training sessions were standardized and supervised by the same instructor. After six months, all participants performed a double-row arthroscopic rotator cuff repair procedure on a benchtop shoulder model providing realistic visual and haptic conditions with implants. Two independent surgeons with expertise in shoulder repair and blinded to the randomization rated the participants' performance using the Arthroscopic Surgical Skill Evaluation Tool (ASSET).

Results: Demographic characteristics and surgical experience were comparable between the two groups. The ASSET global rating score was higher in the VR+ group than in the VR- group (34.4 ± 3.1 and 30.5 ± 5.7, respectively; p = 0.046) and the VR+ group performed the procedure faster than the VR- group (27.3 ± 3.6 vs. 31.7 ± 0.4 min, respectively; p = 0.003).

Discussion: This study demonstrated that a monthly VR-based program for 6 months was better than standard peer training alone for mastering a complex and sequential rotator cuff repair when using the validated ASSET Score. Overall, nonspecific arthroscopic skills were also higher in the VR+ group.

Level Of Evidence: II, therapeutic study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.otsr.2024.104053DOI Listing

Publication Analysis

Top Keywords

cuff repair
24
rotator cuff
16
simulation improves
12
vr-based training
12
realistic visual
12
visual haptic
12
vr+ group
12
training
8
complex sequential
8
training simulation
8

Similar Publications

Introduction Pelvic organ prolapse (POP) affects up to 30% of women during their lifetime and significantly impairs quality of life. In Japan, laparoscopic sacrocolpopexy was covered by national insurance starting in 2014 and has become an established treatment option. Objective This study evaluates the long-term outcomes of POP surgery, including recurrence and complications, seven years after the introduction of sacrocolpopexy at our institution.

View Article and Find Full Text PDF

Enhanced rotator cuff tendon-bone interface regeneration with injectable manganese-based mesoporous silica nanoparticle-loaded dual crosslinked hydrogels.

Front Bioeng Biotechnol

August 2025

Department of Sports Medicine, The First Affiliated Hospital, Guangdong Provincial Key Laboratory of Speed Capability, The Guangzhou Key Laboratory of Precision Orthopedics and Regenerative Medicine, Jinan University, Guangzhou, Guangdong, China.

Introduction: During the healing process, the functional gradient attachment of the rotator cuff (RC) tendon-bone interface fails to regenerate, which severely impedes load transfer and stress dissipation, thereby increasing the risk of retears. As a result, the treatment of rotator cuff tears remains a significant clinical challenge.

Methods: In this study, a dual-crosslinked hyaluronic acid/polyethylene glycol (HA/PEG) hydrogel scaffold was synthesized using hyaluronic acid and polyethylene glycol as base materials.

View Article and Find Full Text PDF

Background: Tranexamic acid (TXA) is an anti-fibrinolytic agent that has effectively reduced transfusion risk and minimized blood loss after total joint arthroplasty. TXA use has had mixed results on postoperative pain after arthroscopic rotator cuff repair (ARCR). The purpose of this prospective, double-blind, randomized, controlled trial was to examine the impact of TXA on prescription opioid consumption for three postoperative days in an outpatient population after ARCR.

View Article and Find Full Text PDF

Background: Rotator cuff disease affects over 50% of individuals over age 70, with more than 250,000 rotator cuff repair (RCR) surgeries performed annually in the U.S. Despite its benefits, 20-30% of repairs fail, and patient-reported outcome measures (PROMs) are widely used to assess recovery, though none are fully validated for RCR-specific use.

View Article and Find Full Text PDF

Rotator cuff tears (RCTs) are a prevalent cause of shoulder dysfunction, with postoperative retearing remaining a significant challenge due to poor tendon-to-bone healing. Mesenchymal stem cells (MSCs), owing to their multipotency, immunomodulatory properties, and diverse tissue sources, have emerged as a promising therapeutic strategy. Current approaches include direct MSC implantation, MSC-laden scaffolds for structural support, and utilization of MSC-derived conditioned medium (CM) or exosomes to enhance regeneration.

View Article and Find Full Text PDF