Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To evaluate the digital guide technique for removing fiber posts from molars and compare it with the conventional microscope-assisted ultrasound method.

Methods: Two mandibular dentition models, each comprising six extracted molars, were prepared. Two thick and straight canals distributed separately in the distal and mesial roots of each molar were selected for placing the fiber posts. The 24 posts in the two dentition models were removed using 3D-printed resin guides, or a microscope and an ultrasonic device. The time taken to remove the fiber post from each tooth was recorded. The volume loss, deviation values (angular deviation and horizontal and vertical deviations of the tip), and formation of microcracks before and after fiber post removal were determined using micro-computed tomography images.

Results: The digital guide technique took significantly less time than the microscope-assisted ultrasound technique (p < 0.05). No significant differences in horizontal and vertical tip deviations were observed between the two groups. The angular deviation and volume loss in the guide group were significantly lower than those in the ultrasound group (p < 0.05). New dentin microcracks were formed in the ultrasound group but not in the digital guide group.

Conclusion: Using a 3D-printed resin guide plate can shorten the fiber post removal time and improve the stability and safety compared to the microscope-assisted ultrasound technique.

Clinical Significance: 3D-printed resin guides can reduce the fiber post removal time and provide better stability and safety than the conventional method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jdent.2024.105462DOI Listing

Publication Analysis

Top Keywords

3d-printed resin
16
fiber post
16
resin guides
12
fiber posts
12
digital guide
12
microscope-assisted ultrasound
12
post removal
12
guide technique
8
dentition models
8
volume loss
8

Similar Publications

Strain sensors have received considerable attention in personal healthcare due to their ability to monitor real-time human movement. However, the lack of chemical sensing capabilities in existing strain sensors limits their utility for continuous biometric monitoring. Although the development of dual wearable sensors capable of simultaneously monitoring human motion and biometric data presents significant challenges, the ability to fabricate these sensors with geometries tailored to individual users is highly desirable.

View Article and Find Full Text PDF

Aim: The aim of this study was to investigate the effect of post-polymerization time and curing device type on the surface roughness, microhardness and color change of 3D printed permanent resin materials.

Materials And Methods: In this study, permanent resin samples with a layer print thickness of 50 μm and dimensions of 10 × 2 mm3 were produced on SLA and DLP printers. The samples were post-polymerized in blue LED and UV LED curing devices for 10, 20, 40 and 60 min.

View Article and Find Full Text PDF

Purpose: To investigate the ability of the smart denture conversion (SDC) technique to produce a stronger interim full-arch implant restoration.

Materials And Methods: Three materials (OnX Tough 3D-printed resin, milled PMMA, and injection molded PMMA) were used to fabricate 180 specimens, 60 specimens per material. Then, an equal number of specimens were assigned a conversion technique: either traditional denture conversion or smart denture conversion.

View Article and Find Full Text PDF

Biofilm control in printed dentures: Effectiveness of hygiene protocols in base and tooth resins.

J Prosthet Dent

September 2025

Full Professor, Department of Dental Materials and Prosthesis, Ribeirão Preto School of Dentistry, University of São Paulo (USP), Ribeirão Preto, São Paulo, Brazil. Electronic address:

Statement Of Problem: Despite the importance of denture hygiene, little is known about how different hygiene protocols perform against multispecies biofilms, including Candida albicans, Staphylococcus aureus, and Streptococcus mutans, on denture surfaces made from conventional versus 3-dimensionally (3D) printed acrylic resins.

Purpose: The purpose of this in vitro study was to evaluate the effect of hygiene protocols on a multispecies biofilm (C albicans, S aureus, and S mutans) formed on resin used for denture bases and teeth.

Material And Methods: Circular specimens (Ø6×2 mm) were made from 3D printed denture resin (n=77) and heat-polymerized resin (n=77).

View Article and Find Full Text PDF

Statement Of Problem: Adjusting the postpolymerization of 3-dimensionally (3D) printed resins can enhance their physical and mechanical properties, improving clinical performance. Understanding which properties may be affected by extended exposure duration is important.

Purpose: The purpose of this systematic review was to investigate the influence of postpolymerization exposure duration on the physical and mechanical properties of 3D printed resins.

View Article and Find Full Text PDF