Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This prospective, preliminary controlled clinical trial investigates the comparative effectiveness of platform-switching (PS) versus traditional butt-joint or platform-matching (PM) implant-abutment connections on peri-implant crestal bone stability. Utilizing a split mouth design, 10 systemically healthy patients (n= 20 implants) had adjacent non-restorable maxillary anterior teeth replaced with two different implants (butt-joint connections and platform-switching interfaces). Patients underwent alveolar ridge preservation, followed by implant placement: platform-matching implants were inserted at crestal bone level, and platform-switching implants were placed 1mm subcrestally. Customized Zirconia crowns were then fabricated for both systems. Outcome measures included bleeding on probing (BOP), probing pocket depth (PPD), and marginal bone loss (MBL), which were evaluated through standardized periapical radiographs over 3-year timeframe. Results showed significantly higher initial MBL in the PM group (0.86 ± 0.13 mm) compared to the PS group (0.34±0.29 mm) [p value: p<0.01]. Moreover, at the three-year follow-up, the crestal bone levels remained above the implant shoulder until the third year of the study for the PS subcrestal group (PS: -0.15±0.39 mm) and slightly below the implant platform in the PM crestal group (PM: 0.55±0.19). After 3 years, the PS group also exhibited lower mean BOP percentages (12%) than the butt-joint group (17%). This study suggests that subcrestal placement with PS and internal connections can provide better long-term peri- implant bone preservation, thereby potentially improving implant success and aesthetic outcomes in the anterior maxillary region.

Download full-text PDF

Source
http://dx.doi.org/10.11607/prd.7277DOI Listing

Publication Analysis

Top Keywords

crestal bone
12
bone stability
8
clinical trial
8
impact implant-abutment
4
implant-abutment connection
4
connection types
4
types crestal
4
bone
4
stability 3-year
4
3-year comparative
4

Similar Publications

Background: The purpose of the study is to evaluate the use of a magnetodynamic instrument (Magnetic Mallet, Metaergonomica, Turbigo, Milan, Italy) to perform a horizontal bone expansion in edentulous sites that need to be rehabilitated with a dental implant.

Methods: A sample of 15 patients, 11 men and 4 women, age between 39 and 78 years, was analyzed. A total of 18 conical-shaped implants with a diameter of 3.

View Article and Find Full Text PDF

Introduction: Soft tissue thickness may play a role in the success of dental implants by influencing factors such as bone health and implant stability. This study aimed to evaluate the effect of mucosal thickness on crestal bone levels and implant stability in patients with platform-switched abutments. The objectives were to measure bleeding on probing (BOP), implant stability, and changes in crestal bone levels in thin and thick mucosal environments over six months post-prosthetic loading.

View Article and Find Full Text PDF

Introduction: Micro-osteoperforation (MOP) is a minimally invasive technique aimed at accelerating orthodontic tooth movement (OTM) by stimulating localised bone remodelling. However, its impact on root resorption, alveolar bone levels, and inflammatory mediators such as interleukin-4 (IL-4) requires further investigation. This study assessed root resorption, alveolar bone changes, canine angulation, rate of retraction, and IL-4 expression associated with MOP-assisted canine retraction.

View Article and Find Full Text PDF

The null hypothesis was that there is no difference in whole salivary cortisol levels (CL) and peri-implant health status among adults with and without a diagnosis of mental health disorders (MHD). The aim was to assess whole salivary CL and peri-implant health status among adults with and without MHD. The inclusion criteria were: (a) adults with at least one dental implant in function for at least one year; (b) adults with and without a diagnosis of MHD.

View Article and Find Full Text PDF

Three-dimensional craniofacial morphology predicts periodontal tissue dimensions using the facial scanner.

J Periodontol

August 2025

Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China.

Background: Despite growing interest in dentofacial interactions, evidence linking three-dimensional (3D) craniofacial morphology to periodontal phenotypes remains sparse. This cross-sectional study aimed to investigate correlations between maxillary anterior periodontal parameters and 3D craniofacial morphology in a Chinese population.

Methods: Participants underwent cone-beam computed tomography (CBCT) and intraoral scans to quantify bone thickness (BT) (at 2 mm [BT] and 4 mm [BT] apical to the alveolar crest), gingival thickness (GT) (at cemento-enamel junction [GT] and bone crest [GT]), and periodontal supra-crestal tissue height (PSTH).

View Article and Find Full Text PDF