Background: Colorectal cancer (CRC) is commonly assessed by computed tomography (CT), but the associated radiation exposure is a major concern. This study aimed to quantitatively and qualitatively compare the image quality of virtual non-contrast (VNC) images reconstructed from arterial and portal venous phases with that of true non-contrast (TNC) images in patients with CRC to assess the potential of TNC images to replace VNC images, thereby reducing the radiation dose.
Methods: A total of 69 patients with postoperative pathologically confirmed CRC at the West China Hospital of Sichuan University between May 2022 and April 2023 were enrolled in this cross-sectional study. The CT protocol included the acquisition of TNC images, arterial and portal venous phase images; the VNC images were reconstructed from the two postcontrast phase images. Several parameters, including the CT attenuation value, absolute attenuation error, imaging noise [standard deviation (SD)], signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR), were measured in multiple abdominal structures for both the TNC and VNC images. Two blinded readers assessed the subjective image quality using a five-point scale. Interobserver agreement was evaluated using interclass correlation coefficients (ICCs). The paired t-test and Wilcoxon signed-rank test were used to compare the objective and subjective results between the TNC and VNC images. Individual measurements of radiation doses for the TNC scan and contrast scan protocols were recorded.
Results: A total of 2,070 regions of interest (ROIs) of the 69 patients were analyzed. Overall, the VNC images exhibited significantly lower attenuation values and SD values than the TNC images in all tissues, except for the abdominal aorta, portal vein, and spleen. The mean absolute attenuation errors between the VNC and TNC images were all less than 10 Hounsfield units (HU). The percentages of absolute attenuation errors less than 5 and 10 HU in the VNC images from the arterial phase (VNCa) were 78.99% and 97.97%, respectively, while those from the portal venous phase (VNCp) were 81.59% and 96.96%, respectively. The absolute attenuation errors between the TNC and VNCa images were smaller than those between the TNC and VNCp images for tumors [VNCaerror: 2.77, interquartile range (IQR) 1.77-4.22; VNCperror: 3.27, IQR 2.68-4.30; P=0.002]. The SNR values and CNR values in the VNC images were significantly higher than those in the TNC images for all tissues, except for the portal vein and spleen. The image quality was rated as excellent (represented by a score of 5) in the majority of the TNC and VNC images; however, the VNC images scored lower than the TNC images. Eliminating the TNC phase resulted in a reduction of approximately 37.99% in the effective dose (ED).
Conclusions: The VNC images provided accurate CT attenuation, good image quality, and lower radiation doses than the TNC images in CRC, and the VNCa images showed minimal differences in the CT attenuation of the tumors.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11400675 | PMC |
http://dx.doi.org/10.21037/qims-24-535 | DOI Listing |
Pediatr Radiol
September 2025
Department of Radiology, University of Colorado School of Medicine/Department of Pediatric Radiology, Children's Hospital Colorado, 13123 East 16th Avenue, Box 125, Aurora, 80045, Colorado, USA.
Background: Previous studies have shown improved image quality in pediatric cardiac imaging using photon-counting detector CT (PCDCT). However, these studies did not evaluate image quality and radiation dose when utilizing the full spectral capabilities of PCDCT scanners. The full spectral capability of PCDCT scanners allows the generation of the entire array of mono-energetic reconstructions, virtual non-contrast (VNC) images, and iodine maps, which have potential advantages in evaluating complex congenital heart disease.
View Article and Find Full Text PDFQuant Imaging Med Surg
September 2025
Department of Radiology, West China Hospital, Sichuan University, Chengdu, China.
Background: Computed tomography (CT) is the preferred imaging modality for evaluating adrenal lesions; however, the associated radiation exposure remains a significant concern. Dual-layer spectral detector CT (SDCT)-derived virtual noncontrast (VNC) images may reduce radiation exposure by eliminating dedicated noncontrast scans, yet their agreement with true noncontrast (TNC) imaging remains debated. This study aimed to quantitatively evaluate the agreement and image quality of VNC images [reconstructed from the arterial phase (VNCa) and portal venous phase (VNCp)] compared to TNC images in adrenal adenomas stratified by lipid content, and to assess the radiation dose reduction.
View Article and Find Full Text PDFEur Radiol Exp
August 2025
Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China.
Background: The value of virtual noncontrast (VNC) images from photon-counting computed tomography (PCCT) for evaluating adrenal lesions and diagnosing adrenal adenomas remains to be clarified.
Materials And Methods: Participants with adrenal masses who underwent unenhanced and portal venous phase PCCT were prospectively included. Portal-venous phase images were reconstructed using conventional VNC (VNC) and PureCalcium VNC (VNC).
Brain Sci
July 2025
Institute of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg, 91054 Erlangen, Germany.
Objective: This study aimed to evaluate whether modifying the post-processing algorithm of Twin-Spiral Dual-Energy computed tomography (DECT) improves infarct detection compared to conventional Dual-Energy CT (DECT) and Single-Energy CT (SECT) following endovascular therapy (EVT) for large vessel occlusion (LVO).
Methods: We retrospectively analyzed 52 patients who underwent Twin-Spiral DECT after endovascular stroke therapy. Ten patients were used to generate a device-specific parameter ("y") using an AI-based neural network (SynthSR).
Emerg Radiol
August 2025
Department of Radiology, Boston Medical Center, Boston University Chobanian & Avedisian School of Medicine, Boston, MA, USA.
Dual-energy computed tomography (DECT) has been widely used in acute clinical settings to add diagnostic confidence and accuracy in head and neck imaging. Given the complexity of the head and neck anatomy, delayed or inaccurate diagnosis of abnormalities involving the head and neck region can result in poor outcomes and possibly life-threatening consequences. This article aims to familiarize radiologists with the clinical applications and limitations of DECT in emergency head and neck imaging to maintain interpretative accuracy and improve patients' outcomes.
View Article and Find Full Text PDF