Article Abstract

Purpose: To compare the visual outcomes of implantable Collamer lens (ICL) with small incision lenticule extraction (SMILE) in cases of moderate-high myopia.

Methods: A prospective comparative study was conducted on 60 eyes of 30 patients with moderate-high myopia (-3D to -8D with astigmatism ≤1 D) at a tertiary eye care center. Patients underwent either SMILE or ICL in both eyes and had a postoperative follow-up of 1 year.

Results: The manifest refractive spherical equivalent was -5.22 ± 1.05 D and -5.4 ± 1.17 D in the SMILE and ICL groups, respectively ( P = 0.53). The mean sphere and cylinder were comparable between the groups. The mean uncorrected visual acuity improved from 1.18 ± 0.19 logMAR to 0.03 ± 0.07 logMAR in SMILE and 1.14 ± 0.25 logMAR to 0.011 ± 0.04 logMAR in the ICL group. The efficacy for SMILE was 83.3% and that for ICL was 93.3%. Safety and predictability (±0.5D) for both was 100%. A significant increase was observed in ocular aberration with a decrease in modular transfer function in the eyes that underwent SMILE, whereas no significant change in the eyes that underwent ICL. A significant difference was observed in all parameters of ocular aberration except corneal trefoil, corneal astigmatism, and PSF between the two groups at the final follow-up. The contrast sensitivity at final follow-up was higher in ICL cases when compared to SMILE. The quality of vision (QoV) score suggested a better QoV with ICL; however, the difference was not statistically significant.

Conclusion: Both SMILE and ICL are safe in patients with moderate-high myopia. The efficacy, contrast sensitivity, and postoperative ocular aberration profile are better in cases undergoing ICL.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11831956PMC
http://dx.doi.org/10.4103/IJO.IJO_908_24DOI Listing

Publication Analysis

Top Keywords

moderate-high myopia
12
smile icl
12
ocular aberration
12
icl
10
visual outcomes
8
outcomes implantable
8
implantable collamer
8
collamer lens
8
small incision
8
incision lenticule
8

Similar Publications

Characteristics of biological parameters and implantable collamer lens (ICL) size selection in moderate, high, and super-high myopia eyes.

BMC Ophthalmol

March 2025

Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute, School of Optometry, Tianjin Medical University Eye Hospital, No. 251, Fukang Road, Nankai District, Tianjin, 30384, China.

Objective: To analyze the characteristics of anterior segment biometric parameters in moderate, high, and super-high myopia eyes for ICL size selection.

Methods: A total of 246 eyes of 131 patients were included in this prospective observational cohort study. Preoperative axis length (AL), central keratometry (Kc), central corneal thickness (CCT), white-to-white (WTW), internal anterior chamber depth (ACD), trabecular iris angle (TIA), anterior chamber width (ACW), angle-to-angle distance (ATA), crystalline lens rise (CLR), lens thickness (LT), sulcus-to-sulcus (STS), ICL size, and postoperative vault at 1 month were recorded and compared among the different degrees of myopia groups.

View Article and Find Full Text PDF

Purpose: To compare the visual outcomes of implantable Collamer lens (ICL) with small incision lenticule extraction (SMILE) in cases of moderate-high myopia.

Methods: A prospective comparative study was conducted on 60 eyes of 30 patients with moderate-high myopia (-3D to -8D with astigmatism ≤1 D) at a tertiary eye care center. Patients underwent either SMILE or ICL in both eyes and had a postoperative follow-up of 1 year.

View Article and Find Full Text PDF
Article Synopsis
  • A study was conducted to evaluate the Eyecryl toric phakic IOL (pIOL) for patients with moderate-to-high myopic astigmatism, focusing on visual and refractive outcomes over three years.
  • The research included 52 eyes from 28 patients, showing a significant improvement in visual acuity and reduction in astigmatism, with 70% of eyes achieving better vision versus preoperative levels.
  • The findings indicate that the Eyecryl toric pIOL is effective and safe, though some patients experienced minor complications, such as cell loss and opacification issues.
View Article and Find Full Text PDF

Outcomes of Cataract Surgery in Eyes With Axial Length > 33 mm.

Am J Ophthalmol

September 2024

Eye Institute, Eye and Ear, Nose, and Throat Hospital, Shanghai Medical College, Fudan University (Y.Z., Y.D., X.Z., Y.L., X.Z.), Shanghai, People's Republic of China; NHC Key Laboratory of Myopia (Fudan University) (Y.Z., Y.D., X.Z., Y.L., X.Z.), Shanghai, People's Republic of China; Key Laboratory

Purpose: To evaluate the visual outcomes and perioperative complications for cataract surgery in eyes with axial length (AL) >33.0 mm.

Design: Prospective clinical cohort study.

View Article and Find Full Text PDF

Purpose: To investigate topographical maps of the three-dimensional choroidal vascularity index (3D-CVI) in children with different levels of myopia.

Methods: We enrolled 274 eyes from 143 children with various severity of myopia, including emmetropia (EM), low myopia (LM), and moderate-high myopia (MHM). The choroidal vessel volume (CVV), choroidal stroma volume (CSV), and 3D-CVI in different eccentricities (fovea, parafovea, and perifovea) and quadrants (nasal, temporal, superior, and inferior) were obtained from swept-source optical coherence tomography angiography (SS-OCTA) volume scans.

View Article and Find Full Text PDF