A motion assessment method for reference stack selection in fetal brain MRI reconstruction based on tensor rank approximation.

NMR Biomed

Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China.

Published: December 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Slice-to-volume registration and super-resolution reconstruction are commonly used to generate 3D volumes of the fetal brain from 2D stacks of slices acquired in multiple orientations. A critical initial step in this pipeline is to select one stack with the minimum motion among all input stacks as a reference for registration. An accurate and unbiased motion assessment (MA) is thus crucial for successful selection. Here, we presented an MA method that determines the minimum motion stack based on 3D low-rank approximation using CANDECOMP/PARAFAC (CP) decomposition. Compared to the current 2D singular value decomposition (SVD) based method that requires flattening stacks into matrices to obtain ranks, in which the spatial information is lost, the CP-based method can factorize 3D stack into low-rank and sparse components in a computationally efficient manner. The difference between the original stack and its low-rank approximation was proposed as the motion indicator. Experiments on linearly and randomly simulated motion illustrated that CP demonstrated higher sensitivity in detecting small motion with a lower baseline bias, and achieved a higher assessment accuracy of 95.45% in identifying the minimum motion stack, compared to the SVD-based method with 58.18%. CP also showed superior motion assessment capabilities in real-data evaluations. Additionally, combining CP with the existing SRR-SVR pipeline significantly improved 3D volume reconstruction. The results indicated that our proposed CP showed superior performance compared to SVD-based methods with higher sensitivity to motion, assessment accuracy, and lower baseline bias, and can be used as a prior step to improve fetal brain reconstruction.

Download full-text PDF

Source
http://dx.doi.org/10.1002/nbm.5248DOI Listing

Publication Analysis

Top Keywords

motion assessment
16
fetal brain
12
minimum motion
12
motion
10
motion stack
8
low-rank approximation
8
stack low-rank
8
higher sensitivity
8
lower baseline
8
baseline bias
8

Similar Publications

IntroductionTo investigate the effectiveness of the remote video-based Strengthening and Stretching for Rheumatoid Arthritis of the Hand (SARAH) exercise program in individuals with rheumatoid arthritis (RA) with wrist involvement.MethodsSeventy-three individuals were included in the study. Wrist joint position sense, wrist joint range of motion, wrist pain, wrist morning stiffness, subjective and objective hand function, grip strength, and disease-related health status were assessed at baseline and after 12 weeks.

View Article and Find Full Text PDF

Purpose: Robotic-assisted total knee arthroplasty (RA-TKA), which is increasingly used to improve surgical precision, can face adoption difficulties due to a learning curve marked by longer operating times. The aim of this study was to evaluate the learning curve associated with the VELYS™ robot in five surgeons from the same centre with different annual arthroplasty volumes using navigated assistance with personalised alignment. The primary aim was to assess the learning curve for each surgeon.

View Article and Find Full Text PDF

Purpose: To assess the functional and subjective outcomes of combined anterior cruciate ligament reconstruction (ACLR) and lateral meniscal root tear (LMRT) repair. Additionally, to compare the use of an independent tunnel for LMRT repair with the ACL bone tunnel technique and to assess the failure rates of LMRT repair to isolated ACLR.

Methods: Patients who underwent primary ACLR and concomitant LMRT repair from May 2017 to May 2022 at Capio Artro Clinic, Stockholm, Sweden, were retrospectively identified and matched 1:3 (age, sex and graft type) with patients who underwent isolated ACLR during the same period.

View Article and Find Full Text PDF

Background: In healthcare education, virtual reality (VR), simulating real-world situations, is emerging as a tool to improve communication skills, particularly in sensitive scenarios involving patients and caregivers. While promising, VR-based education also poses challenges such as avatar realism, cognitive load, and the need for pedagogical grounding.

Objective: This protocol paper presents the VR-TALKS project, which aims to develop, apply, and evaluate VR scenarios designed to teach healthcare students communication skills in serious illness scenarios.

View Article and Find Full Text PDF

Background: Total hip arthroplasty (THA) is a common intervention for severe hip disorders. However, postoperative instability and dislocation continue to present significant challenges. To address these issues, dual mobility (DM) cups and large femoral heads (LFH) have been employed, each offering unique biomechanical benefits.

View Article and Find Full Text PDF