Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Atrial fibrillation (AF) is the most prevalent arrhythmia characterized by intermittent and asymptomatic episodes. However, traditional detection methods often fail to capture the sporadic and intricate nature of AF, resulting in an increased risk of false-positive diagnoses. To address these challenges, this study proposes an intelligent AF detection and diagnosis method that integrates Complementary Ensemble Empirical Mode Decomposition, Power-Normalized Cepstral Coefficients, Bi-directional Long Short-term Memory (CEPNCC-BiLSTM), and photoelectric volumetric pulse wave technology to enhance accuracy in detecting AF. Compared to other approaches, the proposed method demonstrates faster preprocessing efficiency and higher sensitivity in detecting AF while effectively filtering out false alarms from photoplethysmography (PPG) recordings of non-AF patients. Considering the limitations of conventional AF detection evaluation systems that lack a comprehensive assessment of efficiency and accuracy, this study proposes the evaluation system based on F-measurement, which incorporates both computational speed and accuracy to provide a holistic assessment of overall performance. Evaluated with the , the CEPNCC-BiLSTM method outperforms EEMD-based improved Power-Normalized Cepstral Coefficients and Bi-directional Long Short-term Memory (EPNCC-BiLSTM), Support Vector Machine (SVM), EPNCC-SVM, and CEPNCC-SVM methods. Notably, this approach achieves an outstanding accuracy rate of up to 99.2% while processing PPG recordings within 5 s, highlighting its potential for long-term AF monitoring.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11359430PMC
http://dx.doi.org/10.3390/s24165243DOI Listing

Publication Analysis

Top Keywords

intelligent detection
8
atrial fibrillation
8
study proposes
8
power-normalized cepstral
8
cepstral coefficients
8
coefficients bi-directional
8
bi-directional long
8
long short-term
8
short-term memory
8
ppg recordings
8

Similar Publications

The antibiotic contamination in aquatic environments, particularly in aquaculture systems, poses substantial risks to ecological balance and human health. To address this issue, we engineered a novel ratiometric fluorescent probe utilizing dual-emission carbon dots (D-CDs) synthesized from sustainable biomass carrot and nitrogen-rich precursors (melamine and o-phenylenediamine) through an efficient one-pot hydrothermal approach. The D-CDs exhibited dual emission peaks at 425nm and 540 nm under 370nm excitation.

View Article and Find Full Text PDF

In vitro assessment of the inhibitory effect of antiplatelet drugs on platelet aggregation is frequently employed to guide personalized antiplatelet therapy in clinical practice. However, existing methods for detecting platelet aggregation rely heavily on high concentrations of exogenous agonists, which may obscure part of the inhibitory effect of antiplatelet drugs and lead to an underestimation of their effects. This study validates a novel analytical strategy for evaluating the effects of antiplatelet drugs by quantifying the microscopic three-dimensional morphological parameters of platelet aggregates formed through spontaneous aggregation on a glass surface.

View Article and Find Full Text PDF

Accurate brain signal recording and precise electrode placement are critical for the success of neuromodulation therapies such as deep brain stimulation (DBS). Addressing these challenges requires deep brain electrodes that provide high-quality, stable recordings while remaining compatible with high-resolution medical imaging modalities like magnetic resonance imaging (MRI). Moreover, such electrodes shall be cost-effective, easy to manufacture, and patient-compatible.

View Article and Find Full Text PDF

Hair-Like Flexible Airflow Sensor for Large-Area Airflow Sensing.

Adv Sci (Weinh)

September 2025

School of Mechanical & Automotive Engineering, South China University of Technology, Guangzhou, 510641, China.

Recently, flexible airflow sensors have attracted significant attention due to their impressive characteristics and capabilities for airflow sensing. However, the development of high-performance flexible airflow sensors capable of sensing airflow over large areas remains a challenge. In this work, it is proposed that a hair-like flexible airflow sensor, based on laser direct writing and electrostatic flocking, offers an efficient technology for airflow sensing.

View Article and Find Full Text PDF