Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Transcranial magnetic stimulation (TMS) has emerged as a promising neuromodulation technique with both therapeutic and diagnostic applications. As accurate coil placement is known to be essential for focal stimulation, computational models have been established to help find the optimal coil positioning by maximizing electric fields at the cortical target. While these numerical simulations provide realistic and subject-specific field distributions, they are computationally demanding, precluding their use in real-time applications. In this paper, we developed a novel multi-task deep neural network which simultaneously predicts the optimal coil placement for a given cortical target as well as the associated TMS-induced electric field. Trained on large amounts of preceding numerical optimizations, the Attention U-Net-based neural surrogate provided accurate coil optimizations in only 35 ms, a fraction of time compared to the state-of-the-art numerical framework. The mean errors on the position estimates were below 2 mm, i.e., smaller than previously reported manual coil positioning errors. The predicted electric fields were also highly correlated (r> 0.97) with their numerical references. In addition to healthy subjects, we validated our approach also in glioblastoma patients. We first statistically underlined the importance of using realistic heterogeneous tumor conductivities instead of simply adopting values from the surrounding healthy tissue. Second, applying the trained neural surrogate to tumor patients yielded similar accurate positioning and electric field estimates as in healthy subjects. Our findings provide a promising framework for future real-time electric field-optimized TMS applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11339299PMC
http://dx.doi.org/10.1038/s41598-024-70367-wDOI Listing

Publication Analysis

Top Keywords

optimal coil
12
coil placement
12
transcranial magnetic
8
magnetic stimulation
8
multi-task deep
8
accurate coil
8
coil positioning
8
electric fields
8
cortical target
8
electric field
8

Similar Publications

Management and Outcomes of Renal Artery Aneurysms in Older Adults.

Semin Vasc Surg

September 2025

Department of Endovascular and Vascular Surgery, Atrium Health Wake Forest Baptist, 1 Medical Center Blvd, Winston-Salem, NC 27157. Electronic address:

Renal artery aneurysms (RAAs) are rare but clinically significant vascular abnormalities. The management of RAA in older adults poses unique challenges related to their baseline comorbidities and age-related vascular changes. Traditionally, open surgery has been the gold standard for large or complex RAA.

View Article and Find Full Text PDF

Accelerated Patient-specific Non-Cartesian MRI Reconstruction using Implicit Neural Representations.

Int J Radiat Oncol Biol Phys

September 2025

Radiation Oncology, University of California, San Francisco, 505 Parnassus Ave, San Francisco, CA 94143. Electronic address:

Purpose: Accelerating MR acquisition is essential for image guided therapeutic applications. Compressed sensing (CS) has been developed to minimize image artifacts in accelerated scans, but the required iterative reconstruction is computationally complex and difficult to generalize. Convolutional neural networks (CNNs)/Transformers-based deep learning (DL) methods emerged as a faster alternative but face challenges in modeling continuous k-space, a problem amplified with non-Cartesian sampling commonly used in accelerated acquisition.

View Article and Find Full Text PDF

Kappa carrageenan (KC), a sulfated polysaccharide derived from red seaweed, exhibits distinct gelation properties that are influenced by ionic strength and thermal conditions. While its behavior in aqueous media is well-established, understanding KC's gelation mechanisms in non-aqueous solvents (like glycerol) remains limited. This study investigates the conformational and rheological properties of kappa carrageenan in glycerol, focusing on the effects of sodium salts (NaCl, NaHPO, NaPO) at varying concentrations and preparation temperatures (60 °C and 80 °C).

View Article and Find Full Text PDF

Background: SURF was a prospective, multicenter, single-arm, observational study with core lab adjudication of radiographic data, assessing embolization of intracranial aneurysms (IAs) using WAVE Extra Soft Coils as part of SMART Coil System.

Methods: Adults undergoing IA embolization with the SMART Coil System (Penumbra, Inc.) comprising 75% of implanted coils and WAVE as the final finishing coil were enrolled at 43 global centers.

View Article and Find Full Text PDF

∆B shim optimization performed at the beginning of an MR scan is unable to correct for ∆B field inhomogeneities caused by patient motion or hardware instability during scans. Navigator-based methods have been demonstrated previously to be effective for motion and shim correction. The purpose of this work was to accelerate volumetric navigators to allow fast acquisition of the parent navigated sequence with short real-time feedback time and high spatial resolution of the ∆B field mapping.

View Article and Find Full Text PDF