98%
921
2 minutes
20
Background: Although the pathogenesis of acute kidney injury (AKI) in patients with acute coronary syndrome (ACS) undergoing invasive treatment is multifactorial, the role of iodinated contrast media (CM) has been well established. The DyeVert system (Osprey Medical) is designed to reduce the CM volume during invasive coronary procedures while maintaining fluoroscopic image quality.
Objective: The aim of the Renal Insufficiency Following Contrast Media Administration Trial IV (REMEDIAL IV) is to test whether the use of the DyeVert system is effective in reducing contrast-associated acute kidney injury (CA-AKI) rate in patients with ACS undergoing urgent invasive procedures.
Trial Design: Patients with ACS treated by urgent invasive approach will be enrolled. Participants will be randomly assigned into one of the following groups: (1) DyeVert group and (2) control group. In participants enrolled in the DyeVert group, CM injection will be handled by the DyeVert system. On the contrary, in the control group, CM injection will be performed by a conventional manual or automatic injection syringe. In all cases, iobitridol (a low-osmolar, nonionic CM) will be administered. Participants will receive intravenous 0.9% sodium chloride as soon as moved to the catheterization laboratory. The primary end points are CM volume administration and CA-AKI rate (ie, an increase in serum creatinine concentration of ≥0.3 mg/dL within 48 hours after CM exposure). A sample size of at least 522 randomized participants (261 in each group) is needed to demonstrate an 8.5% difference in the CA-AKI rate between the groups (that is, from 19% in the control group to 10.5% in the DyeVert group), with a 2-sided 95% confidence interval and 80% power ( < .05).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11307588 | PMC |
http://dx.doi.org/10.1016/j.jscai.2023.100980 | DOI Listing |
AJR Am J Roentgenol
September 2025
Department of Radiology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China.
Patients with inflammation-associated coronary artery disease (CAD) may exhibit rapid progression and require regular coronary imaging. To evaluate the diagnostic performance of spectral photon-counting detector (PCD) coronary CTA with reduced radiation and contrast media doses for detecting coronary stenosis and in-stent restenosis in patients with inflammation-associated CAD. This prospective study enrolled patients with inflammation-associated CAD from January 2023 to March 2024.
View Article and Find Full Text PDFMed Phys
September 2025
Department of Radiology, Stony Brook University, New York, USA.
Background: In contrast-enhanced digital mammography (CEDM) and contrast-enhanced digital breast tomosynthesis (CEDBT), low-energy (LE) and high-energy (HE) images are acquired after injection of iodine contrast agent. Weighted subtraction is then applied to generate dual-energy (DE) images, where normal breast tissues are suppressed, leaving iodinated objects enhanced. Currently, clinical systems employ a dual-shot (DS) method, where LE and HE images are acquired with two separate exposures.
View Article and Find Full Text PDFBiotechnol Bioeng
September 2025
Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, New York, USA.
In this work, confocal microscopy is employed to study the loading and fouling behavior in AAV affinity resins as well as the implications of resin reuse with several commercial chromatographic materials and feed mixtures. Resin samples are obtained from both batch and column experiments, and confocal microscopy is carried out to examine the adsorption profiles in the beads after loading, wash, elution, and CIP steps. A comparison of PSDVB-based POROS CaptureSelect (PCS) AAV resins with agarose-based AVIPure AAV9 resins revealed distinct differences in both AAV transport and resin fouling.
View Article and Find Full Text PDFIEEE Trans Med Imaging
September 2025
In ultrasound imaging, propagation of an acoustic wavefront through heterogeneous media causes phase aberrations that degrade the coherence of the reflected wavefront, leading to reduced image resolution and contrast. Adaptive imaging techniques attempt to correct this phase aberration and restore coherence, leading to improved focusing of the image. We propose an autofocusing paradigm for aberration correction in ultrasound imaging by fitting an acoustic velocity field to pressure measurements, via optimization of the common midpoint phase error (CMPE), using a straight-ray wave propagation model for beamforming in diffusely scattering media.
View Article and Find Full Text PDFRadiology
September 2025
Department of Magnetic Resonance Imaging, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Background MRI-derived arrhythmogenic substrate, including late gadolinium enhancement (LGE) and extracellular volume fraction (ECV), is indicative of sudden cardiac death (SCD) risk in nonischemic dilated cardiomyopathy (DCM). The relative prognostic value of LGE and ECV remains unclear. Purpose To evaluate the performance of LGE and T1 mapping in predicting SCD in patients with DCM and to explore clinical implementation.
View Article and Find Full Text PDF