Background: Safety events and technical success (TS) have been previously reported for aortic and pulmonary valvuloplasty, but a composite performance measure as a novel, patient-centered strategy has neither been developed nor been studied. This study aims to refine a procedural performance (PP) variable, a composite of TS and procedural safety, for isolated, standard-risk aortic and pulmonary valvuloplasty.
Methods: A multicenter review was performed using data from the Congenital Cardiac Catheterization Project on Outcomes registry. Data were collected for all cases of isolated balloon aortic and pulmonary valvuloplasty from 2014 through 2017. Patients were excluded if they were aged <1 month, were inpatient at the time of the procedure, or had significant comorbidities, such as Williams or Noonan syndrome. Criteria for TS were developed and categorized (optimal, satisfactory, and unsatisfactory) by expert consensus based on previous outcome research. Adverse events (AE) were categorized by severity (level 1-5) using established criteria. Level 4 and 5 severity AE were considered high-severity AE. Using criteria of TS and AE severity, PP was divided into 3 composite outcome classes. Factors correlating with class III (suboptimal) PP were analyzed.
Results: There were 169 cases of aortic and 270 cases of pulmonary valvuloplasty in the cohorts. In the aortic valvuloplasty cohort, a suboptimal PP (class III) occurred in 14% of cases, mostly due to high-severity AE (7%). No significant correlation between patient or case characteristics and PP was demonstrated. In the pulmonary valvuloplasty cohort, class III PP occurred in 9% of cases, predominantly due to residual valve gradient, which correlated with lower weight ( = .02).
Conclusions: We designed a composite variable of PP consisting of TS and safety as a comprehensive measure of outcome. Incorporating both TS and AE may better reflect patient outcome than each metric measured separately. PP indices may identify areas for further investigation and quality improvement.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11308845 | PMC |
http://dx.doi.org/10.1016/j.jscai.2023.101119 | DOI Listing |
Eur Heart J Cardiovasc Imaging
September 2025
Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.
Aims: Fetal circulation undergoes complex changes in congenital heart disease (CHD) that are challenging to assess with fetal echocardiography. This study aimed to assess clinical feasibility and diagnostic value of 4D flow cardiac magnetic resonance (CMR) in fetal CHD.
Methods And Results: Pregnant women in advanced third trimester pregnancy with fetal CHD were prospectively recruited for fetal CMR between 08/2021 and 11/2024.
PLoS One
September 2025
Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Korea.
Volumetric modulated arc therapy (VMAT) for lung cancer involves complex multileaf collimator (MLC) motion, which increases sensitivity to interplay effects with tumour motion. Current dynamic conformal arc methods address this issue but may limit the achievable dose distribution optimisation compared with standard VMAT. This study examined the clinical utility of a VMAT technique with monitor unit limits (VMATliMU) to mimic conformal arc delivery and reduce interplay effects while maintaining plan quality.
View Article and Find Full Text PDFESC Heart Fail
September 2025
Department of Cardiac-, Thoracic-, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany.
Aims: Non-pharmacological therapies for acute decompensated heart failure (HF) and cardiogenic shock have evolved considerably in recent decades. Short-term mechanical circulatory support (MCS) devices can be used as circulatory backup. While nearly all available devices use continuous flow, evidence indicates that pulsatile flow can be more effective.
View Article and Find Full Text PDFJTCVS Open
August 2025
Department of Anaesthesia and Intensive Care Medicine, Royal Papworth Hospital, Cambridge Biomedical Campus, Cambridge, United Kingdom.
Objective: Postoperative intraluminal thrombosis after frozen elephant trunk replacement has been reported to occur with a frequency of 6% to 17% and is associated with poor outcomes. The purpose of this institutional review is to analyze thrombosis rate, predisposing patient and operative factors, and assess different anticoagulation regimens.
Methods: This retrospective cohort study includes 174 patients operated on over 10 years.
JTCVS Open
August 2025
Division of Cardiac Surgery, Northwestern University Feinberg School of Medicine and Northwestern Medicine Bluhm Cardiovascular Institute, Chicago, Ill.
Objective: Limited data are available on treatment of atrial fibrillation during ascending aortic aneurysm and aortic valve surgery. Ablation at the time of isolated aortic valve surgery has a Society of Thoracic Surgeons Class I indication. We sought to determine early and late outcomes of concomitant atrial fibrillation surgery at the time of ascending aortic aneurysm + aortic valve surgery.