Article Abstract

Objective: To assess the prediction accuracy of recent optical and numerical models for the spectral reflectance and color of monolithic samples of dental materials with different thicknesses.

Methods: Samples of dental resin composites of Aura Easy Flow (Ae1, Ae3 and Ae4 shades) and Estelite Universal Flow Super Low (A1, A2, A3, A3.5, A4 and A5 shades) with thicknesses between 0.3 and 1.8 mm, as well as Estelite Universal Flow Medium (A2, A3, OA2 and OA3 shades) with thicknesses between 0.4 and 2.0 mm, were used. Spectral reflectance and transmittance factors of all samples were measured using a X-Rite Color i7 spectrophotometer. Four analytical optical models (2 two-flux models and 2 four-flux models) and two numerical models (PCA-based and L*a*b*-based) were implemented to predict spectral reflectance of all samples and then convert them into CIE-L*a*b* color coordinates (D65 illuminant, 2°Observer). The CIEDE2000 total color difference formula (ΔE) between predicted and measured colors, and the corresponding 50:50% acceptability and perceptibility thresholds (AT and PT) were used for performance assessment.

Results: The best performing optical model was the four-flux model RTE-4F-RT, with an average ΔE = 0.72 over all samples, 94.87% of the differences below AT and 65.38% below PT. The best performing numerical model was L*a*b*-PCHIP (interpolation mode), with an average ΔE = 0.48, and 100% and 79.69% of the differences below AT and PT, respectively.

Significance: Both optical and numerical models offer comparable color prediction accuracy, offering flexibility in model choice. These results help guide decision-making on prediction methods by clarifying their strengths and limitations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.dental.2024.07.013DOI Listing

Publication Analysis

Top Keywords

numerical models
16
optical numerical
12
spectral reflectance
12
reflectance color
8
color prediction
8
dental resin
8
resin composites
8
prediction accuracy
8
samples dental
8
estelite universal
8

Similar Publications

Self-propulsive active nematics.

Philos Trans A Math Phys Eng Sci

September 2025

Niels Bohr Institute, University of Copenhagen, Kobenhavn, Capital Region of Denmark 2100, Denmark.

Increasing evidence suggests that active matter exhibits instances of mixed symmetry that cannot be fully described by either polar or nematic formalism. Here, we introduce a minimal model that integrates self-propulsion into the active nematic framework. Our linear stability analyses reveal how self-propulsion shifts the onset of instability, fundamentally altering the dynamical landscape.

View Article and Find Full Text PDF

Microswimmer locomotion in non-Newtonian fluids is crucial for biological processes, including infection, fertilization and biofilm formation. The behaviour of microswimmers in these media is an area with many conflicting results, with swimmers displaying varying responses depending on their morphology, actuation and the complex properties of the surrounding fluid. Using a hybrid computational approach, we numerically investigate the effect of shear-thinning rheology and viscoelasticity on a simple conceptual microswimmer consisting of three linked spheres.

View Article and Find Full Text PDF

Background: Changes to the calculation of the Kidney Donor Profile Index (KDPI) have lowered the KDPI of hepatitis C (HCV+) donor kidneys; therefore, increasing the proportion of pediatric-prioritized kidneys that are HCV+. We aimed to study consent rates for HCV+ kidneys among pediatric kidney transplant candidates.

Methods: We identified pediatric candidates waitlisted from 2019 to 2024 and excluded those who received a living donor transplant.

View Article and Find Full Text PDF

Purpose: This study sought to determine the intrasession repeatability of the diffusion-weighted (DW) arterial spin labeling (ASL) sequence at different postlabel delays (PLDs).

Methods: We first performed numerical simulations to study the accuracy of the two-compartment water exchange rate (Kw) fitting model with added Gaussian noise for DW PLDs at 1500, 1800, and 2100 ms. Ten young, healthy participants then underwent a structural T scan and two intrasession in vivo DW ASL scans at each PLD on a 3T MRI.

View Article and Find Full Text PDF

Aims: To find out how Kenyan nurses rate their organisational culture, determine their level of job satisfaction, and organisational culture predictors of job satisfaction.

Design: A cross-sectional online survey.

Methodology: A total of 300 nurses across Kenya were invited to participate in this study.

View Article and Find Full Text PDF