Article Abstract

Study Design: Modified Delphi consensus study.

Objective: To develop consensus-based best practices for the care of pediatric patients who have implanted programmable devices (IPDs) and require spinal deformity surgery.

Summary Of Background Data: Implanted programmable devices (IPDs) are often present in patients with neuromuscular or syndromic scoliosis who require spine surgery. Guidelines for monitoring and interrogating these devices during the perioperative period are not available.

Methods: A panel was assembled consisting of 25 experts (i.e., spinal deformity surgeons, neurosurgeons, neuroelectrophysiologists, cardiologists, and otolaryngologists). Initial postulates were based on a literature review and results from a prior survey. Postulates addressed the following IPDs: vagal nerve stimulators (VNS), programmable ventriculoperitoneal shunts (VPS), intrathecal baclofen pumps (ITBP), cardiac pacemakers and implantable cardioverter-defibrillators (ICD), deep brain stimulators (DBS), and cochlear implants. Cardiologist and otolaryngologist participants responded only to postulates on cardiac pacemakers or cochlear implants, respectively. Consensus was defined as ≥80% agreement, items that did not reach consensus were revised and included in subsequent rounds. A total of 3 survey rounds and 1 virtual meeting were conducted.

Results: Consensus was reached on 39 total postulates across 6 IPD types. Postulates addressed general spine surgery considerations, the use of intraoperative monitoring and cautery, the use of magnetically controlled growing rods (MCGRs), and the use of an external remote controller to lengthen MCGRs. Across IPD types, consensus for the final postulates ranged from 94.4% to 100%. Overall, experts agreed that MCGRs can be surgically inserted and lengthened in patients with a variety of IPDs and provided guidance for the use of intraoperative monitoring and cautery, which varied between IPD types.

Conclusion: Spinal deformity correction surgery often benefits from the use of intraoperative monitoring, monopolar and bipolar cautery, and MCGRs. The final postulates from this study can inform the perioperative and postoperative practices of spinal deformity surgeons who treat patients with both scoliosis and IPDs.

Level Of Evidence: V-Expert opinion.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BRS.0000000000005061DOI Listing

Publication Analysis

Top Keywords

spinal deformity
20
intraoperative monitoring
12
consensus-based best
8
perioperative postoperative
8
care pediatric
8
pediatric patients
8
implanted programmable
8
programmable devices
8
devices ipds
8
spine surgery
8

Similar Publications

Study Design: Narrative review.

Objective: To synthesize current knowledge on radiographic parameters, classification systems, and compensatory mechanisms essential to the diagnosis and surgical planning of cervical spine deformity (CD) correction.

Summary Of Background Data: CD encompasses a heterogeneous set of conditions associated with neurological impairment and impaired health-related quality of life.

View Article and Find Full Text PDF

Thoracic aortic injury as a complication of spinal surgery: A new case and systematic review (1991-2024).

J Vasc Surg Cases Innov Tech

December 2025

Faculdade de Ciências Médicas de Alagoas, Vascular and Endovascular Surgery Division, Alagoas, Alagoas, Brazil.

Background: Iatrogenic thoracic aortic injury (TAI) is a rare but well-recognized complication of spine surgery, lacking standardized treatment guidelines due to its rarity and variability of manifestations.

Methods: We present a new case of TAI successfully managed with endovascular repair and systematically reviewed 52 articles (1991-2024) reporting 64 cases, including demographics, surgical indications, injury patterns, and treatments.

Results: A 53-year-old man with a T7 fracture underwent posterior spinal instrumentation and developed chest pain due to a combination of impingement and screw penetration into the thoracic aorta and was treated with thoracic endovascular aortic repair (TEVAR) and removal of pedicle screws.

View Article and Find Full Text PDF

Background: Complex interbody fusion remains challenging, while traditional surgical instruments are not suitable for complex spinal deformities. Porous tantalum (Ta) has excellent osteogenic properties, but there is currently a lack of research on its application in cervical thoracic interbody fusion.

Objective: To introduce the application of selective electron beam melting (SEBM) 3D printing technology in customized porous Ta vertebral fusion implants and evaluate its mid-term clinical efficacy in complex cervical thoracic fusion surgery.

View Article and Find Full Text PDF

Myotonic dystrophy type 1 (DM1) is an inherited neuromuscular disorder characterized by muscle weakness, atrophy and myotonia, with multi-system involvement. Recent studies have highlighted the pathological heterogeneity within the CNS of DM1 patients, particularly significant changes in spinal transcriptome expression and alternative splicing. In this study, we conducted a comprehensive transcriptome analysis of the spinal cord in the muscle-specific DM1 mouse model and their wild-type controls across different life stages: young, adult and old age.

View Article and Find Full Text PDF

Purpose: This study aims to validate the usefulness of T10-pelvic angle (T10PA) in predicting pelvic tilt (PT) restoration, proximal junctional kyphosis (PJK) development, and clinical outcomes after adult spinal deformity (ASD) surgery.

Methods: This retrospective study included 213 ASD patients who underwent fusion from the lower thoracic spine (T9 or T10) to the pelvis. T10PA was measured on 6-week postoperative radiographs as the angle between the center of T10 and the hip center, and from the hip center to the midpoint of the S1 upper endplate.

View Article and Find Full Text PDF