System optimization study of hybrid K-edge/XRF densitometer for uranium-plutonium solution measurement.

Appl Radiat Isot

Fundamental Science on Radioactive Geology and Exploration Technology Laboratory, East China University of Technology, Nanchang, 330013, China.

Published: August 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In this paper, a comprehensive hybrid K-edge/XRF densitometer (HKED) device model is constructed using MCNP simulation. After the modeling process, a systematic simulation study is conducted to analyze the physical parameters and material selection of KED and XRF. The simulation results reveal that the optimal parameters for the X-ray tube are an X-ray source voltage of 160 kV and a 1 mm Fe filter. The sample should be placed in a vial with an inner diameter of 1.4 cm and an outer diameter of 2 cm. For the KED technique, the determined main parameters are a 1.9 cm Fe filter rod and an inner diameter of 0.08 cm for the collimator. For the XRF technique, the determined main parameters are a 0.01 cm Gd filter and an inner diameter of 0.3 cm for the collimator, with a detector angle of 150°. After selecting appropriate parameters, the average calibration factor Δμ of the KED technique was found to be 3.301 cm g, with a relative standard deviation (RSD) of 3.36%. Additionally, the comparison between the simulated and calculated values of uranium concentration revealed a minimum measurement error of 0.4%. The minimum detection concentration of KED for uranium solutions is approximately 1 g/L. For plutonium solutions ranging from 0.5 to 20 g/L, linear fitting of the K net peak area and plutonium concentration showed a coefficient of determination (R) of 0.999. The detection limit of XRF for plutonium measurement was 2.33✕10 g/L. The linear fitting coefficients (R) of uranium concentration versus K-edge transmission rate and plutonium concentration versus K net peak area for the hybrid technique in measuring uranium-plutonium mixed solutions are determined as 0.999 and 0.996, respectively, demonstrating the response relationship of the HKED device to uranium and plutonium under different concentrations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2024.111367DOI Listing

Publication Analysis

Top Keywords

inner diameter
12
hybrid k-edge/xrf
8
k-edge/xrf densitometer
8
hked device
8
ked technique
8
technique determined
8
determined main
8
main parameters
8
uranium concentration
8
linear fitting
8

Similar Publications

To study the impact of pH-responsive labels prepared using traditional and different printing methods on fruit freshness monitoring and preservation, this study firstly optimized coaxial 3D printed labels by analyzing core-shell ratios and infill ratios, and predicted the impact of printing design on functionality of labels via four models. Then, the physicochemical properties of cast, dual-nozzle 3D printed, and coaxial 3D printed labels were compared. Finally, lightweight deep convolutional neural network models were used to enhance early warning intelligence.

View Article and Find Full Text PDF

Background: Nodular hidradenoma (NH) is a rare benign adnexal tumor originating from sweat glands, often misdiagnosed due to nonspecific clinical manifestations. Ultrasonography (US) plays a critical role in the diagnosis of skin tumors, yet systematic descriptions of its sonographic features remain limited.

Objective: This study aims to investigate the very-high-frequency (VHF) characteristics of eccrine nodular hidradenoma (ENH) and establish key imaging criteria to differentiate it from other cutaneous/subcutaneous lesions.

View Article and Find Full Text PDF

Objective: We aimed to investigate the differences in the lengths and shapes of several preformed nasotracheal tubes (NTTs) among different manufacturers and compare our findings with a previous report.

Methods: Using reference points at the tube tip, the proximal edge of the cuff, and the flexion point, we measured tube lengths for NTTs with inner diameters of 6.5, 7.

View Article and Find Full Text PDF

Temporary silicone oil tamponade for persistent macular holes: a multicentre study.

Br J Ophthalmol

September 2025

Department of Ophthalmology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany

Background: Persistent full-thickness macular holes (FTMHs) following primary surgery represent a therapeutic challenge. Various surgical treatment approaches have been proposed. This study evaluates anatomical and functional outcomes of a temporary silicone oil tamponade in persistent FTMH in a larger cohort.

View Article and Find Full Text PDF

The Influence of Embedded Properties on the Liberation Characteristics of Macerals in Subbituminous Coal.

ACS Omega

September 2025

CHN ENERGY CORNERSTONE CHEMICAL TECHNOLOGY (SHANGHAI) CO.,LTD, Shanghai 201100, China.

The utilization pathways of coal macerals exhibit a significant variability. The efficient separation of active and inert components in coal is critical for realizing their high value-added applications. The liberation efficiency of coal macerals directly influences the accuracy of subsequent separation processes.

View Article and Find Full Text PDF