Determination of meropenem in capillary plasma microsamples using LC-MS/MS.

Bioanalysis

Laboratório de Toxicologia Analítica, Universidade Feevale, Rua Rubem Berta 200, Novo Hamburgo, Rio Grande do Sul, Brazil.

Published: June 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The measurement of meropenem plasma concentrations is employed for dosing regimen individualization. The aim of this study was to develop and validate a LC-MS/MS assay for quantification of meropenem in capillary plasma microsamples. Samples were prepared by protein precipitation with acetonitrile, followed by clean-up with dichloromethane. The method was validated and applied to 12 paired samples of venous and capillary plasma. The method was linear in the range of 0.5-50 μg/ml. Matrix effects were minimal. Inter- and intra-assay were 3.8-7.9% and 2.7-5.5%, respectively, while accuracy was 91.7-100.6%. Concentrations in capillary and venous plasma were highly correlated. An assay for the quantification of meropenem in capillary plasma microsamples was fully validated, showing potential for clinical application.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11216516PMC
http://dx.doi.org/10.4155/bio-2023-0268DOI Listing

Publication Analysis

Top Keywords

capillary plasma
16
meropenem capillary
12
plasma microsamples
12
assay quantification
8
quantification meropenem
8
plasma
6
capillary
5
determination meropenem
4
microsamples lc-ms/ms
4
lc-ms/ms measurement
4

Similar Publications

Background: Light chain multiple myeloma (LCMM) is a malignant hematological disease characterized by bone marrow infiltration by tumor plasma cells and the secretion of monoclonal free light chains (κ or λ). It is often di-agnosed through hypogammaglobulinemia detected by serum protein electrophoresis, followed by immunotyping showing a monoclonal band in free light chains. However, the structure of monoclonal light chains can sometimes complicate laboratory findings.

View Article and Find Full Text PDF

A 62-year-old female was admitted to our hospital with abdominal pain, diarrhea, and bloody stool. She suffered from severe diarrhea 30 times per day and consequently got hypoalbuminemia and hyponatremia. Esophagogastroduodenoscopy and total colonoscopy showed diffuse erosion of the duodenum, terminal ileum, and colorectum.

View Article and Find Full Text PDF

Plasma-driven biocatalysis utilizes in situ HO production by atmospheric pressure plasmas to drive HO-dependent enzymatic reactions. Having previously established plasma-driven biocatalysis using recombinant unspecific peroxygenase from Agrocybe aegerita (rAaeUPO) to produce (R)-1-phenylethanol from ethylbenzene, we here employed CypC from Bacillus subtilis 168 (synonyms: YbdT, P450BSβ), an integral enzyme of surfactin and fengycin biosynthesis. CypC naturally hydroxylates medium and long-chain carboxylic acids.

View Article and Find Full Text PDF

Extracellular vesicles (EVs) have emerged as promising biomarkers in cancer diagnostics. However, rapid and nondestructive isolation of EVs from plasma remains challenging due to the presence of abundant interferents with smaller sizes (e.g.

View Article and Find Full Text PDF

We investigated metabolite responses to different swimming intensities in 16 highly trained swimmers (9 males, 7 females, aged 16-24 years). After determining critical swimming speed (CS) with a 12 × 25 m maximal effort test, participants completed three swimming trials at moderate (below CS), heavy (at CS), and severe (above CS) intensities on separate days. Capillary blood samples (1 mL) were collected before and after each trial for metabolite profiling via mass spectrometry.

View Article and Find Full Text PDF