Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Variation in practice exists for temperature probe positioning during stabilization of very preterm infants (<32 weeks gestation). We explored the influence of temperature probe sites on thermoregulation.

Methods: An open-label, stratified, balanced, parallel, randomized trial was conducted. Inborn infants were randomly assigned temperature probe to the axilla or to the upper back. The primary outcome was normothermia (local range: 36.8-37.3 °C and World Health Organization (WHO) range: 36.5-37.5 °C) at admission to the neonatal intensive care unit.

Results: Between 1 November 2018 and 4 July 2022, 178 infants were randomly assigned to one of the two sites (n = 89 each), 175 included in the final analysis. Normothermia (local range) was achieved for 39/87 infants (44.8%) assigned to the upper back compared to 28/88 infants (31.8%) assigned to the axilla [risk difference:13%; 95% CI -1.3-27.3]. Normothermia (WHO range) was achieved for 78/87 infants (89.7%) assigned to the upper back compared to 70/88 infants (79.6%) assigned to the axilla [risk difference:10.1%; 95% CI -0.5-20.7]. No infant recorded temperatures >38 °C or developed skin injury.

Conclusions: In very preterm infants, upper back site was equally effective as the axilla in maintaining normothermia, with no increase in adverse events.

Clinical Trial Registration: The study was registered with the Australian New Zealand Clinical Trials Registry (ACTRN12620000293965).

Impact: Substantial variation in practice exists for the site of securing a temperature probe during delivery room stabilization of very preterm infants and the influence of temperature probe site on thermoregulation remains unknown. In this study, upper back site was equally effective as the axilla in maintaining normothermia, with no increase in adverse events. Clinicians could adopt upper back site for maintaining normothermia. This study may contribute data to future international participant data prospective meta analysis of randomized controlled trials worldwide on temperature probe positioning in very preterm infants, increasing translation of research findings to optimize thermoregulation and clinical outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11257937PMC
http://dx.doi.org/10.1038/s41390-024-03115-5DOI Listing

Publication Analysis

Top Keywords

temperature probe
20
preterm infants
20
upper site
12
maintaining normothermia
12
delivery room
8
room stabilization
8
variation practice
8
practice exists
8
probe positioning
8
stabilization preterm
8

Similar Publications

First-principles insights into structure and magnetism in ultra-small tetrahedral iron oxide nanoparticles.

Phys Chem Chem Phys

September 2025

Masaryk University, Faculty of Science, Department of Chemistry, Kotlářská 2, Brno, 611 37, Czech Republic.

Structural and magnetic properties of ultra-small tetrahedron-shaped iron oxide nanoparticles were investigated using density functional theory. Tetrahedral and truncated tetrahedral models were considered in both non-functionalized form and with surfaces passivated by pseudo-hydrogen atoms. The focus on these two morphologies reflects their experimental relevance at this size scale and the feasibility of performing fully relaxed, atomistically resolved first-principles simulations.

View Article and Find Full Text PDF

Probing the Influence of Water on the Molecular Mobility of PVP/VA using Terahertz Spectroscopy.

Mol Pharm

September 2025

Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge CB3 0AS, U.K.

The presence of water significantly impacts the physical stability of amorphous solid dispersions (ASDs) by altering polymer molecular mobility. This study investigates the influence of low levels of absorbed water on the molecular dynamics and glass transition behavior of amorphous poly(vinylpyrrolidone--vinyl acetate) (PVP/VA). Melt-quenched PVP/VA discs were conditioned at controlled relative humidities (RH 8.

View Article and Find Full Text PDF

An innovative 4D targeted method was developed for the determination of 61 bioactive compounds in royal jelly (RJ) related to their health-promoting properties. The method, apart from high-resolution mass spectrometry, exploits the advantages of vacuum-insulated probe-heated electrospray ionization source (VIP-HESI), reducing thermal degradation, and trapped ion mobility spectrometry (TIMS), improving selectivity and compound identification. The optimization of VIP-HESI ionization parameters using experimental designs showed that the critical parameters were the capillary voltage as well as the probe gas flow rate and temperature.

View Article and Find Full Text PDF

With the rapid development of precision medicine and the continuous evolution of smart wearable devices, photothermal materials (PTMs) are experiencing a tremendous opportunity for growth. PTMs can efficiently convert light energy into heat to achieve localized thermal therapy for specific cells or tissues, offering advantages of minimal invasiveness, high selectivity, and precise targeting. Furthermore, PTMs can serve as molecular imaging probes and smart drug carriers, integrating multiple functions such as bioimaging and drug delivery to realize the visualization and controlled release of therapeutic processes.

View Article and Find Full Text PDF

Background: Pulsed electric field ablation (PFA) techniques for treating cardiac arrhythmias have attracted considerable interest. For example, atrial fibrillation can be effectively treated by pulmonary vein isolation using PFA. However, some arrhythmias originate deep within the myocardium, making them difficult to reach with conventional ablation methods.

View Article and Find Full Text PDF