Numerical study on the hydrodynamic performance and internal flow of an axial-flow pump with various inlet flow angles.

Sci Rep

Carbon Neutral Technology R&D Department, Research Institute of Clean Manufacturing System, Korea Institute of Industrial Technology, 89 Yangdaegiro-gil, Ipjang-Myeon, Seobuk-gu, Cheonan-si, 31056, Chungcheongnam-do, Republic of Korea.

Published: December 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In this study, numerical simulation was employed to predict the performance and internal flow characteristics of the inlet of an axial-flow pump by assigning an absolute flow angle to the inlet guide vane (IGV) trailing-edge flow. Further, the finite volume method based on the three-dimensional Reynolds-averaged Navier-Stokes equations was employed to discretize the governing equations. The shear stress transport model was used as the turbulence model, and an appropriate number of nodes were selected for the hexahedral grid system through a grid-dependency test. The performance curve and changes in the internal flow field were investigated based on the variation in the flow angle at the inlet of the axial-flow pump. These results can be used to establish an efficient operational plan by adjusting the IGV angle of IGV when installing a variable IGV for an axial-flow pump.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10724269PMC
http://dx.doi.org/10.1038/s41598-023-49671-4DOI Listing

Publication Analysis

Top Keywords

axial-flow pump
16
internal flow
12
performance internal
8
inlet axial-flow
8
flow angle
8
angle inlet
8
flow
7
numerical study
4
study hydrodynamic
4
hydrodynamic performance
4

Similar Publications

Objective: Fontan surgery constructs Total Cavo-Pulmonary Connection Circulation (TCPC), but lacks power. Cavopulmonary circulation assist devices (CPAD) has been proposed to support the Fontan circulation. The virtual implantation of blood pumps into the real TCPC structure to analyze the output characteristics of blood pump and flow pattern can better guide design of the pump and the formulation of powered Fontan surgical protocols.

View Article and Find Full Text PDF

Platelet derived prothrombotic microparticles (MP) have been associated with hemocompatibility related adverse events in patients with continuous flow left ventricular assist devices; little is known with the contemporary Impella platform micro-axial flow pumps. Indeed, the extended duration of support provided by the Impella 5.5 calls for a specific evaluation.

View Article and Find Full Text PDF

Right Ventricular Longitudinal Strain Predicts Weaning Success in Cardiogenic Shock Patients Supported by a Microaxial Flow Pump.

Crit Care Explor

July 2025

Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité, Campus Virchow Klinikum, Berlin, Germany.

Importance: The effect of left ventricular (LV) mechanical unloading on right ventricular (RV) function in patients with cardiogenic shock (CS) remains poorly understood, yet may have significant implications for device weaning and patient outcomes.

Objectives: To investigate the short-term effects of LV unloading using a transaortic valve axial flow pump (Impella) on RV function and to assess its predictive value for successful device weaning in patients with CS.

Design: Retrospective analysis of CS patients who received Impella support between 2018 and 2021.

View Article and Find Full Text PDF

The Impella 5.5 (Abiomed, USA) is a catheter-based micro-axial flow pump that has emerged as a vital tool in managing patients with cardiogenic shock (CS). Delivering up to 5.

View Article and Find Full Text PDF

The rising number of people with heart failure is leading to a corresponding increase in heart failure-related deaths. End-of-life care for these patients involves supplementing standard treatments with therapies aimed at managing symptoms that don't respond to guideline-directed medical care. The INCOR, a lightweight (200 g), implantable, magnetically levitated axial flow pump (providing non-pulsatile flow), is designed for long-term left ventricular support.

View Article and Find Full Text PDF