Advances in nanostructured material-based non-enzymatic electrochemical glucose sensors.

Anal Methods

Engineering Research Center of Clinical Functional Materials and Diagnosis & Treatment Devices of Zhejiang Province, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325001, PR China.

Published: November 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Non-enzymatic electrochemical sensors that use functional materials to directly catalyze glucose have shown great promise in diabetes management, food control, and bioprocess inspection owing to the advantages of high sensitivity, long-term stability, and low cost. Recently, in order to produce enhanced electrochemical behavior, significant efforts have been devoted to the preparation of functional materials with regular nanostructure, as it provides high specific surface area and well-defined strong active sites for electrochemical sensing. However, the structure-performance correlation in this field has not been reviewed thoroughly in the literature. This review aims to present a comprehensive report on advanced zero- to three-dimensional nanostructures based on the geometric feature and to discuss in depth their structural effects on enzyme-free electrochemical detection of glucose. It starts by illustrating the sensing principles of nanostructured materials, followed by a detailed discussion on the structural effects related to the features of each dimension. The structure-performance correlation is explored by comparing the performance derived from diverse dimensional architectures, which is beneficial for the better design of regular nanostructure to achieve efficient enzyme-free sensing of glucose. Finally, future directions of non-enzymatic electrochemical glucose sensors to solve emerging challenges and further improve the sensing performance are also proposed.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d3ay01664aDOI Listing

Publication Analysis

Top Keywords

non-enzymatic electrochemical
12
electrochemical glucose
8
glucose sensors
8
functional materials
8
regular nanostructure
8
structure-performance correlation
8
structural effects
8
electrochemical
6
glucose
5
advances nanostructured
4

Similar Publications

Rational design of hierarchical CuO/CuO/SnO branched supernanowires for highly sensitive non-enzymatic glucose sensors.

Nanoscale

September 2025

National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou, Jiangsu 215123, China.

The rational design and synthesis of one-dimensional hierarchical heterojunction materials for high-performance electrocatalytic applications present an enticing prospect in the field of electrochemistry. Herein, barnyardgrass-like CuO/CuO/SnO branched supernanowires were rationally designed and controllably prepared a synergistic process of co-precipitation and microwave treatment to achieve highly sensitive non-enzymatic glucose sensors. These prepared CuO/CuO/SnO ternary hierarchical heterostructures possessed a specific surface area of 102.

View Article and Find Full Text PDF

Automated exo-glycosidase-based glycan sequencing on a digital microfluidic system with integrated electrochemical detection of monosaccharides.

Biosens Bioelectron

December 2025

Guangdong-Hong Kong-Macau Joint Laboratory on Micro-Nano Manufacturing Technology, Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen, 518055, China; Advanced Materials Innovation Center, Jiaxing Research Institute of Southern University of Scien

Glycans are one of the most important biomacromolecules and are essential to nearly all known life forms. However, their structural complexity makes structural analysis more challenging than nucleic acids or proteins, significantly limiting the opportunities for investigating their structure-function relationship. Here, we proposed a novel glycan sequencing strategy in which a suite of specific non-reducing-end exoglycosidases was integrated with electrochemical detection of monosaccharides in a digital microfluidic (DMF) chip.

View Article and Find Full Text PDF

Herein, a novel synthetic method is proposed to obtain hollow few-layer TiCT nanosheets@Ni-Fe layered double hydroxide microrods (TiCT@NiFe-LDH), which includes the coating process of MIL-88A microrods by two-dimensional TiCT nanosheets, the pre-adsorption process of 2-methylimidazole on the surfaces of MIL-88A@TiCT microrods, and the co-precipitation process of Ni and Fe with the interlayer of fumaric acid anions, resulting in the unique material structure of TiCT@NiFe-LDH. More importantly, hollow microrods composed of TiCT and NiFe-LDH nanosheets show the structural advantages, which are responsible for the high-performance behaviors towards the non-enzymatic detection of glucose, leading to 0.5-115.

View Article and Find Full Text PDF

Enzyme-Free Monitoring of Glucose Using Molecularly Imprinted Polymers and Gold Nanoparticles.

Biosensors (Basel)

August 2025

BioMark@UC/CEMMPRE (Centre for Mechanical Engineering, Materials and Processes)-ARISE (Advanced Production and Intelligent Systems), Faculty of Sciences and Technology, Department of Chemical Engineering, University of Coimbra, 3030-790 Coimbra, Portugal.

This work describes a non-enzymatic electrochemical glucose biosensor combining for the first time molecularly imprinted polymers (MIPs) for glucose concentration and gold nanoparticles (AuNPs) on screen-printed carbon electrodes (SPEs), where both MIPs and AuNPs were assembled in situ. Electrochemical impedance spectroscopy (EIS) was used to evaluate the analytical performance of the sensor, which has a linear range between 1.0 µM and 1.

View Article and Find Full Text PDF

Non-Enzymatic Selective Detection of Histamine in Fishery Product Samples on Boron-Doped Diamond Electrodes.

Biosensors (Basel)

July 2025

Department of Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Kanagawa, Japan.

Histamine sensing that uses enzymatic reactions is the most common form of testing due to its selectivity for histamine. However, enzymes are difficult to store for long periods of time, and the inactivation of enzymes decreases the reliability of the results. In this study, we developed a novel, quick, and easily operated histamine sensing technique that takes advantage of the histamine redox reaction and does not require enzyme-based processes.

View Article and Find Full Text PDF