98%
921
2 minutes
20
Microchannel plate (MCP) photomultiplier tubes (PMTs) are frequently used in experimental diagnostics, where they are operated in single-pulse current measurement mode. However, considering the significant amplitude fluctuations in the measured signal, the resulting output signal from the MCP-PMT is inevitably distorted by gain saturation. Therefore, understanding the correlation between the MCP-PMT output signal and gain saturation is critical in assessing the extent of output signal distortion and determining the MCP-PMT saturation level. This knowledge allows for a more precise assessment of the input signal's features. In this paper, we present an experimental method for restoring the initial waveform from the saturated MCP-PMT signal. To correct the amplitude-drop caused by gain saturation, our technique involves calibrating the MCP-PMT's relative gain as a function of the accumulated output charge using a square-wave light source. We then applied this approach to restore a ∼500 ns saturated pulse from a double-layer 10 mm diameter MCP-PMT. The restored signal showed a deviation of less than 6% from the reference waveform, which validates the effectiveness of the technique.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/5.0161838 | DOI Listing |
Nat Immunol
September 2025
Walter and Eliza Hall Institute of Medical Research, Parkville, Victoria, Australia.
CD4 T follicular helper (T) cells support tailored B cell responses against multiple classes of pathogens. To reveal how diverse T phenotypes are established, we profiled mouse T cells in response to viral, helminth and bacterial infection. We identified a core T signature that is distinct from CD4 T follicular regulatory and effector cells and identified pathogen-specific transcriptional modules that shape T function.
View Article and Find Full Text PDFJ Neurophysiol
September 2025
Graduate School of Science and Technology, Shinshu University, 3-15-1 Tokida, Ueda, Nagano 3868567, Japan.
This study investigated the correlation between the strength of correlated effective neural drive (END) to the antagonistic muscles and the fluctuations in neural/electrical and mechanical output around the joint during steady co-contraction, and whether the correlated END strength estimated from conventional surface EMG is correlated with that determined from motor unit (MU) discharges. Fourteen young male participants performed isometric steady co-contractions with their medial gastrocnemius and tibialis anterior muscles at 10% of maximal EMG while sitting. Correlated END strength was quantified as the maximum value of the cross-correlation function between the conventional surface EMG signals and between MU discharges decomposed from high-density surface EMG of each muscle.
View Article and Find Full Text PDFAnal Chem
September 2025
School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo 255049, PR China.
Pax-5a gene, as a nucleic acid biomarker closely associated with B-cell acute lymphoblastic leukemia (B-ALL), holds significant potential for early disease diagnosis. In this study, we developed a highly accurate and efficient "on-super on-off" photoelectrochemical (PEC) biosensor based on a dual-photoelectrode heterojunction system integrated with a multisphere cascade DNA amplification strategy. The designed heterojunction dual-photoelectrode platform, comprising a InO/CdS photoanode (on state) and an in situ-formed MIL-68(In)/InO (MIO) photocathode, effectively extends the electron-hole transport pathway, enhances photogenerated charge separation, and produces high-amplitude signal output (super on state), thereby providing a robust baseline for signal transduction.
View Article and Find Full Text PDFIEEE Trans Pattern Anal Mach Intell
September 2025
In this paper, we propose a novel framework, Combo, for harmonious co-speech holistic 3D human motion generation and efficient customizable adaption. In particular, we identify that one fundamental challenge as the multiple-input-multiple-output (MIMO) nature of the generative model of interest. More concretely, on the input end, the model typically consumes both speech signals and character guidance (e.
View Article and Find Full Text PDFAnal Chem
September 2025
College of Natural Resources and Environment, South China Agricultural University, Guangzhou 510642, China.
A series of molecular logic gates with multiple biocomputing capabilities have been successfully fabricated by using four antibiotic residues [tetracycline (TET), chloramphenicol (CHL), kanamycin (KAN), and streptomycin (STR)] as inputs. The lateral flow strip biosensor was utilized to realize the visual and portable sensing of logic events. Four basic logic gates (OR, AND, XOR, and INHIBIT) and three cascade logic circuits (OR-INHIBIT-AND, 3AND-OR, and XOR-INHIBIT-OR-AND) were constructed.
View Article and Find Full Text PDF