Background: Environmental cleaning is important in the interruption of pathogen transmission. Although prevention initiatives have targeted environmental cleaning, practice variations exist and compliance is low. Evaluation of human factors influencing variations in cleaning practices can be valuable in developing interventions to standardized practices. We conducted a work-system analysis using a human-factors engineering (HFE) framework to identify barriers and facilitators to environmental cleaning practices in acute and long-term care settings within the Veterans' Affairs health system.
Methods: We conducted a qualitative study with key stakeholders at 3 VA facilities. We analyzed transcripts for thematic content and mapped themes to the HFE framework.
Results: Staffing consistency was felt to improve cleaning practices and teamwork. We found that many environmental management service (EMS) staff were veterans who were motivated to serve fellow veterans, especially to prevent infections. However, hiring veterans comes with regulatory hurdles that affect staffing. Sites reported some form of monitoring their cleaning process, but there was variation in method and frequency. The EMS workload was affected by whether rooms were occupied by patients or were semiprivate rooms; both were reportedly more difficult to clean. Room design and surface finishes were identified as important to cleaning efficiency.
Conclusion: HFE work analysis identified barriers and facilitators to environmental cleaning. These findings highlight intervention entry points that may facilitate standardized work practices. There is a need to develop task-specific procedures such as cleaning occupied beds and semiprivate rooms. Future research should evaluate interventions that address these determinants of environmental cleaning.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1017/ice.2023.226 | DOI Listing |
ACS Appl Mater Interfaces
September 2025
Department of Chemical Engineering, School of Chemical Engineering, Dalian University of Technology, Dalian 116024, P. R. China.
Developing scalable and robust deicing coatings is essential for real-world applications, yet current coatings either suffer from intrinsic fragility or low thermal conductivity, limiting sustainability and deicing effectiveness. Here, we report a scalable and durable photothermal superhydrophobic coating coupling with enhanced thermal conductivity, engineered by embedding carbon nanotubes within a perfluoroalkoxy polymer matrix. Our design achieved 97.
View Article and Find Full Text PDFInt J Biol Macromol
September 2025
Liaoning Key Laboratory of Lignocellulose Chemistry and Biomaterials, School of Light Industry and Chemical Engineering, Dalian Polytechnic University, Dalian, 116034, China. Electronic address:
Traditional phenolic resin adhesives involve the use of petrochemical-based phenol, raising environmental and health concerns. In this study, lignin was demethylated to substitute for phenol and prepare a high-lignin-content adhesive with perfect shear strength performance. The hydroxyl content of demethylated lignin can reach up to 6.
View Article and Find Full Text PDFArq Gastroenterol
September 2025
The Japanese Society of Internal Medicine, Editorial Department, Tokyo, Japan.
Background: This study aims to analyze research trends and emerging insights into gut microbiota studies from 2015 to 2024 through bibliometric analysis techniques. By examining bibliographic data from the Web of Science (WoS) Core Collection, it seeks to identify key research topics, evolving themes, and significant shifts in gut microbiota research. The study employs co-occurrence analysis, principal component analysis (PCA), and burst detection analysis to uncover latent patterns and the development trajectory of this rapidly expanding field.
View Article and Find Full Text PDFPLoS One
September 2025
Sterile Processing Department, Sichuan GEM Flower Hospital, North Sichuan Medical College, Chengdu, China.
Background: Luminal instruments are characterized by their slender internal lumens, which make them particularly challenging to clean and dry. A common drying method used by Sterile Processing Department (SPD) technicians involves blowing high-pressure air into one end of the lumen to expel moisture. However, this process generates a significant amount of aerosols that may contain bacteria, viruses, and other microorganisms.
View Article and Find Full Text PDFSoc Work Public Health
September 2025
School of Social Work, Jackson State University, Jackson, Mississippi, USA.
In 2021, Jackson, Mississippi, received national attention after a winter storm caused the failure of operations at the city's largest water treatment facility. Years of neglect to a crumbling infrastructure triggered the Jackson water crisis, leaving residents without clean and reliable access to water. Predating any one administration, Black and low-income residents had long raised concerns about excessive water bills, broken water mains, poor water quality, and deterioration of the city's water system.
View Article and Find Full Text PDF