Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The patient-centered healthcare requires timely disease diagnosis and prognostic assessment, calling for individualized physiological monitoring. To assess the postoperative hemodynamic status of patients, implantable blood flow monitoring devices are highly expected to deliver real time, long-term, sensitive, and reliable hemodynamic signals, which can accurately reflect multiple physiological conditions. Herein, an implantable and unconstrained vascular electronic system based on a piezoelectric sensor immobilized is presented by a "growable" sheath around continuously growing arterial vessels for real-timely and wirelessly monitoring of hemodynamics. The piezoelectric sensor made of circumferentially aligned polyvinylidene fluoride nanofibers around pulsating artery can sensitively perceive mechanical signals, and the growable sheath bioinspired by the structure and function of leaf sheath has elasticity and conformal shape adaptive to the dynamically growing arterial vessels to avoid growth constriction. With this integrated and smart design, long-term, wireless, and sensitive monitoring of hemodynamics are achieved and demonstrated in rats and rabbits. It provides a simple and versatile strategy for designing implantable sensors in a less invasive way.

Download full-text PDF

Source
http://dx.doi.org/10.1002/smll.202304752DOI Listing

Publication Analysis

Top Keywords

monitoring hemodynamics
12
piezoelectric sensor
8
growing arterial
8
arterial vessels
8
monitoring
5
unconstrained piezoelectric
4
piezoelectric vascular
4
vascular electronics
4
electronics wireless
4
wireless monitoring
4

Similar Publications

Effect of ECMO Flow Variations on Pulmonary Capillary Wedge Pressure in Patients With Cardiogenic Shock.

J Am Coll Cardiol

September 2025

Service de Médecine Intensive-Réanimation, Institut de Cardiologie, Assistance Publique-Hôpitaux de Paris (AP-HP), Sorbonne Université, Hôpital Pitié-Salpêtrière, Paris, France; Sorbonne Université, INSERM, UMRS_1166-ICAN, Institute of Cardiometabolism and Nutrition, Paris, France.

Background: The hemodynamic effects of femoro-femoral venoarterial (VA) extracorporeal membrane oxygenation (ECMO) on pulmonary capillary wedge pressure (PCWP) remain poorly defined. High ECMO flow is believed to increase PCWP and the risk of pulmonary edema; yet, supporting in vivo physiological data are lacking.

Objectives: The purpose of this study was to evaluate the impact of incremental femoro-femoral VA-ECMO flow variations on PCWP, hemodynamic, and echocardiographic parameters in patients with cardiogenic shock during the early phase of VA-ECMO support, after stabilization.

View Article and Find Full Text PDF

Reading fluency is a vital building block for developing literacy, yet the best way to practice fluency-reading aloud-can cause anxiety severe enough to inhibit literacy development in ways that can have an adverse effect on students through adulthood. One promising intervention to mitigate oral reading anxiety is to have children read aloud to a robot. Although observations in prior work have suggested that people likely feel more comfortable in the presence of a robot instead of a human, few studies have empirically demonstrated that people feel less anxious performing in front of a robot compared with a human or used objective physiological indicators to identify decreased anxiety.

View Article and Find Full Text PDF

Skin-adaptive focused flexible micromachined ultrasound transducers for wearable cardiovascular health monitoring.

Sci Adv

September 2025

State Key Laboratory for Manufacturing System Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme En

Continuous monitoring of cardiovascular vital signs can reduce the incidence and mortality of cardiovascular diseases, yet cannot be implemented by current technologies because of device bulkiness and rigidity. Here, we report self-adhesive and skin-conformal ultrasonic transducer arrays that enable wearable monitoring of multiple hemodynamic parameters without interfering with daily activities. A skin-adaptive focused ultrasound method with rational array design is proposed to implement measurement under wide ranges of skin curvatures and depths with improved sensing performances.

View Article and Find Full Text PDF

Anomalous Origin of the Right Coronary Artery from the Left Main Coronary Artery in A Patient with Non-Specific Chest Pain.

Eur J Case Rep Intern Med

August 2025

Cardiac Sciences Division, Department of Medicine, King Abdulaziz Hospital, Ministry of National Guard Health Affairs (MNGHA), Al Ahsa, Saudi Arabia.

Unlabelled: Anomalous origin of the coronary arteries is a rare congenital condition that can present as non-specific chest pain or shortness of breath or remain asymptomatic. Early identification is critical as certain variants are linked with a high risk of sudden cardiac death. Here, we report the case of a 53-year-old female with hypertension, hypothyroidism, obesity (class II) and a history of intermittent chest pain radiating to the left arm for two years.

View Article and Find Full Text PDF