Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Geometric distortion is a major limiting factor for spatial specificity in high-resolution fMRI using EPI readouts and is exacerbated at higher field strengths due to increased B field inhomogeneity. Prominent correction schemes are based on B field-mapping or acquiring reverse phase-encoded (reversed-PE) data. However, to date, comparisons of these techniques in the context of fMRI have only been performed on 2DEPI data, either at lower field or lower resolution. In this study, we investigate distortion compensation in the context of sub-millimetre 3DEPI data at 7T. B field-mapping and reversed-PE distortion correction techniques were applied to both partial coverage BOLD-weighted and whole brain MT-weighted 3DEPI data with matched distortion. Qualitative assessment showed overall improvement in cortical alignment for both correction techniques in both 3DEPI fMRI and whole-brain MT-3DEPI datasets. The distortion-corrected MT-3DEPI images were quantitatively evaluated by comparing cortical alignment with an anatomical reference using dice coefficient (DC) and correlation ratio (CR) measures. These showed that B field-mapping and reversed-PE methods both improved correspondence between the MT-3DEPI and anatomical data, with more substantial improvements consistently obtained using the reversed-PE approach. Regional analyses demonstrated that the largest benefit of distortion correction, and in particular of the reversed-PE approach, occurred in frontal and temporal regions where susceptibility-induced distortions are known to be greatest, but had not led to complete signal dropout. In conclusion, distortion correction based on reversed-PE data has shown the greater capacity for achieving faithful alignment with anatomical data in the context of high-resolution fMRI at 7T using 3DEPI.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10951962PMC
http://dx.doi.org/10.1016/j.neuroimage.2023.120294DOI Listing

Publication Analysis

Top Keywords

distortion correction
12
susceptibility-induced distortions
8
3depi fmri
8
high-resolution fmri
8
reversed-pe data
8
3depi data
8
field-mapping reversed-pe
8
correction techniques
8
cortical alignment
8
alignment anatomical
8

Similar Publications

Unlabelled: The popularity of an opinion in one's direct circles is not necessarily a good indicator of its popularity in one's entire community. Network structures make local information about global properties of the group potentially inaccurate, and the way a social network is wired constrains what kind of information distortion can actually occur. In this paper, we discuss which classes of networks allow for a large enough proportion of the population to get a wrong enough impression about the overall distribution of opinions.

View Article and Find Full Text PDF

Autonomous systems operating in high-dimensional environments increasingly rely on prioritization heuristics to allocate attention and assess risk, yet these mechanisms can introduce cognitive biases such as salience, spatial framing, and temporal familiarity that influence decision-making without altering the input or accessing internal states. This study presents Priority Inversion via Operational Reasoning (PRIOR), a black-box, non-perturbative diagnostic framework that employs structurally biased but semantically neutral scenario cues to probe inference-level vulnerabilities without modifying pixel-level, statistical, or surface semantic properties. Given the limited accessibility of embodied vision-based systems, we evaluate PRIOR using large language models (LLMs) as abstract reasoning proxies to simulate cognitive prioritization in constrained textual surveillance scenarios inspired by Unmanned Aerial Vehicle (UAV) operations.

View Article and Find Full Text PDF

In this work, we developed a vacuum-compatible long trace profiler (LTP) for in situ metrology of ultra-precise x-ray optics within synchrotron vacuum chambers. Although traditional LTPs operate ex situ under atmospheric pressure, earlier optical setups-such as that by Qian et al.-performed in situ distortion measurements by directing laser beams through vacuum viewports.

View Article and Find Full Text PDF

∆B shim optimization performed at the beginning of an MR scan is unable to correct for ∆B field inhomogeneities caused by patient motion or hardware instability during scans. Navigator-based methods have been demonstrated previously to be effective for motion and shim correction. The purpose of this work was to accelerate volumetric navigators to allow fast acquisition of the parent navigated sequence with short real-time feedback time and high spatial resolution of the ∆B field mapping.

View Article and Find Full Text PDF

Background: Photon-counting computed tomography (CT) bears promise to substantially improve spectral and spatial resolution. One reason for the relatively slow evolution of photon-counting detectors in CT-the technology has been used in nuclear medicine and planar radiology for decades-is pulse pileup, that is, the random staggering of pulses, resulting in count loss and spectral distortion, which in turn cause image bias and reduced contrast-to-noise ratio (CNR). The deterministic effects of pileup can be mitigated with a pileup-correction algorithm, but the loss of CNR cannot be recovered, and must be minimized by hardware design.

View Article and Find Full Text PDF