The concurrent validity and reliability of virtual reality to measure shoulder flexion and scaption range of motion.

Physiotherapy

Therapy Department, Central London Community Healthcare National Health Service Trust, London, United Kingdom; Department of Musculoskeletal Research, Clinical Therapies, University of Limerick, Ireland.

Published: September 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Shoulder pain commonly has a detrimental impact on patient's work and social activities. Although pain is the most common reason for seeking care, a reduction in shoulder range of motion (ROM) is another common impairment. ROM assessment is used as an evaluation tool and multiple methods are available to measure shoulder ROM. Virtual reality (VR) has been introduced into shoulder rehabilitation, mostly when exercise and ROM measurement is indicated. This study evaluated the concurrent validity and system reliability of active ROM measurements of VR for people with and without shoulder pain.

Methods: Forty volunteers participated in this study. Virtual goniometry was used to assess active shoulder ROM. Participants performed flexion and scaption to six predetermined angles. Measurements from the VR goniometer and smartphone inclinometers were recorded simultaneously. To assess reliability, two identical test sequences were performed.

Results: The concurrent validity ICCs were 0.93 for shoulder flexion and 0.94 for shoulder scaption. The VR goniometer application on average systematically overestimated the ROM compared to the smartphone inclinometer. The mean difference between goniometer values was -11.3 degrees for flexion and -10.9 for scaption. The system reliability was excellent with an overall ICC of 0.99 for the flexion movements and 0.99 for the scaption movements.

Conclusion: Although the VR system demonstrated excellent reliability, and high ICC's for concurrent validity, the large range between the lower and upper 95% CI limits suggests it lacks measurement precision. This suggests VR, as used in this study, should not be used interchangeably with other measurement tools. CONTRIBUTION OF THE PAPER.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.physio.2023.06.005DOI Listing

Publication Analysis

Top Keywords

concurrent validity
16
shoulder
9
virtual reality
8
measure shoulder
8
shoulder flexion
8
flexion scaption
8
range motion
8
shoulder rom
8
system reliability
8
rom
7

Similar Publications

Background And Hypotheses: Sexual minority youth are at increased risk for psychotic experiences, potentially due to identity-related difficulties. We hypothesized that sexual minority youth would report greater identity difficulties, and that these difficulties would be associated with heightened suspiciousness in daily life. Finally, we examined whether these associations differ between sexual minority and heterosexual adolescents.

View Article and Find Full Text PDF

A rapid and specific liquid chromatography-tandem mass spectrometry method with a wide linear range was developed and validated for the simultaneous quantification of Vitamin K1 (VK1) trans- and cis- isomers in human plasma. Bovine serum albumin solution (15%) served as a surrogate matrix for preparing the calibrators to establish the quantitative curves. After liquid-liquid extraction, VK1 trans- and cis- isomers in plasma samples were separated on a ChromCore C30 column (15 cm × 4.

View Article and Find Full Text PDF

Objective: This study validates the previously tested Screening for Poverty And Related social determinants to improve Knowledge of and access to resources ('SPARK Tool') against comparison questions from well-established national surveys (Post Survey Questionnaire (PSQ)) to inform the development of a standardised tool to collect patients' demographic and social needs data in healthcare.

Design: Cross-sectional study.

Setting: Pan-Canadian study of participants from four Canadian provinces (SK, MB, ON and NL).

View Article and Find Full Text PDF

This rapid systematic review aimed to evaluate the diagnostic accuracy (concurrent validity, predictive ability, reliability) of indirect calorimetry (IC) for measuring resting energy expenditure (REE) in adults with overweight or obesity. PubMed and Web of Science searched for studies measuring REE by IC in adults with overweight or obesity and reported primary outcomes: concurrent validity, predictive ability, or reliability. N = 22 studies were included that evaluated n = 10 IC devices.

View Article and Find Full Text PDF

RNA-protein interactions critically regulate gene expression and cellular processes, yet their comprehensive mapping remains challenging due to their structural diversity. We introduce PRIM-seq (protein-RNA interaction mapping by sequencing), a method for concurrent de novo identification of RNA-binding proteins and their associated RNAs. PRIM-seq generates unique chimeric DNA sequences by proximity ligation of RNAs with protein-linked DNA barcodes, which are subsequently decoded through sequencing.

View Article and Find Full Text PDF