Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: In the current tumor-node-metastasis (TNM) classification, the clinical T descriptor is defined by solid size (SS) on a computed tomography (CT) slice and the pathological one is done by invasive size (IS) in microscopic evaluations. We sometimes experience discrepancies in diagnosis of both descriptors. A volume analyzing application enables semi-automatic measurement of three-dimensional (3D) parameters in cases where there are discrepancies in diagnosing tumors' solid size and IS. In this study, we aimed to evaluate the association between 3D parameters and pathological invasion in non-solid small-sized lung adenocarcinomas.

Methods: We enrolled 246 consecutive patients who underwent pulmonary resection at Shizuoka Cancer Center. Patients with lung adenocarcinomas that were radiologically non-solid, node-negative and sized ≤3 cm were eligible. We used a volume analyzing application to retrospectively measure 3D parameters of max and mean Hounsfield units (HUs) and solid volume (SV). The cut-off value of these parameters for diagnosing invasive adenocarcinoma (IAD) was set by describing receiver operating characteristic (ROC) curves. The correlation of IAD with these parameters was compared to its correlation with the SS. This study was not registered.

Results: Of 246 patients with adenocarcinoma, 183 (74.4%) had IADs. In multivariate analyses, the total size (TS) and SS were significantly associated with IAD (P=0.006, 0.001, respectively), whereas 3D parameters including SV were not (P=0.80). In radiological adenocarcinoma (2.1-3.0 cm), SV >300 mm diagnosed IAD with a higher sensitivity than that of the SS (0.93 and 0.83, respectively).

Conclusions: TS >20 mm and SS >5 mm were well-correlated with IAD. SV measurement may complement the current computed tomographic diagnosis of IAD based on the SS (2.1-3.0 cm).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10323566PMC
http://dx.doi.org/10.21037/jtd-22-1603DOI Listing

Publication Analysis

Top Keywords

solid volume
8
pathological invasion
8
invasion non-solid
8
solid size
8
volume analyzing
8
analyzing application
8
parameters
6
iad
6
diagnostic sensitivity
4
solid
4

Similar Publications

Purpose: Bronchiolar adenoma (BA) is a rare benign pulmonary neoplasm originating from the bronchial mucosal epithelium and mimics lung adenocarcinoma (LAC) both radiographically and microscopically. This study aimed to develop a nomogram for distinguishing BA from LAC by integrating clinical characteristics and artificial intelligence (AI)-derived histogram parameters across two medical centers.

Methods: This retrospective study included 215 patients with diagnoses confirmed by postoperative pathology from two medical centers.

View Article and Find Full Text PDF

Neuroblastoma is the most common extracranial solid tumor in children, requiring multidisciplinary treatment, including radiotherapy, which is primarily applied in the high-risk group to prevent disease progression. The review highlights indications for radiotherapy, its role in multimodal treatment, and addresses aspects of radiotherapy planning, including target volume definition, prescribed radiation doses, optimal timing for radiotherapy implementation, and potential side effects. Particular attention is drawn to the lack of consensus regarding the necessity of an additional radiation dose for persistent residual disease in the primary tumor and the irradiation of metastatic sites remaining after induction therapy.

View Article and Find Full Text PDF

Measuring the stress tensor in nitrogen-doped CVD diamond using solid-state quantum sensor.

Sci Technol Adv Mater

August 2025

Research Center for Electronic and Optical Materials, National Institute for Materials Science, Tsukuba, Ibaraki, Japan.

We measured the residual stress tensor in a nitrogen-doped chemical vapor deposition (001) diamond film. The stress tensor was evaluated from the amount of the shift in optically detected magnetic resonance (ODMR) spectra of NV center in the diamond. A confocal microscopy setup was used to observe the spatial variation of the stress tensor in the diamond film.

View Article and Find Full Text PDF

Waste biomass has aroused increasing interest in the production of low-cost materials for CO adsorption and supercapacitors. One of the primary facets in this regard is to develop nanoporous carbons with controlled porosity and high surface area. Herein, waste wood chips are used to synthesize nanoporous biocarbons via a solid-state KOH-based chemical activation.

View Article and Find Full Text PDF

Changes in consumption patterns, urbanization, and industrialization have led to the generation of large volumes of municipal solid waste (MSW), posing threats to environmental sustainability. This study aimed to compost the organic fraction of municipal solid waste (OFMSW) using three composting methods: windrow (WC), pit (PC), and drum composting (DC). Distilled water was used in compost preparation and sample analysis.

View Article and Find Full Text PDF