Low complexity adaptive ultrasound image beamformer combined with improved multiphase apodization with cross-correlation.

Ultrasonics

State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing 400044, China.

Published: September 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In this paper, an ultrasound imaging method combined with low-complexity adaptive beamformer (LCA) and improved multiphase apodization with cross-correlation (IMPAX) is proposed to improve image resolution and contrast with low hardware cost. Firstly, the delayed echo signal is apodized by the LCA to obtain a narrow mainlobe width echo signal and LCA output. Then, multiple pairs of complementary square-wave phase apodizations are applied to the apodized echo signal to obtain corresponding signal pairs, which are used to calculate the normalized cross-correlation (NCC) matrix. Finally, the average value of the NCC matrices is filtered by 2-D means, and the filtered result is introduced as the weighting factor for the LCA output. The simulation and experimental results show that the proposed LCA-IMPAX can effectively reduce the mainlobe width, suppress clutter, and be robust to noise. Compared with DAS, LCA, and MPAX, for simulated point targets, the full-width at half-maximum (FWHM, -6dB) of LCA-IMPAX is reduced by 49.22%, 10.06%, and 48.67%, respectively. For simulated cyst, the CR is improved by 219.91%, 138.08%, and 103.44%, respectively. For experimental cysts, the CR is improved by an average of 145.00%, 136.14%, and 55.09%, respectively. The results of human heart data indicate that LCA-IMPAX has good imaging quality in vivo. Since the proposed method does not involve covariance matrix inversion, it can be applied in real-time imaging systems.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultras.2023.107084DOI Listing

Publication Analysis

Top Keywords

echo signal
12
improved multiphase
8
multiphase apodization
8
apodization cross-correlation
8
mainlobe width
8
lca output
8
lca
5
low complexity
4
complexity adaptive
4
adaptive ultrasound
4

Similar Publications

Designing Spin-Correlated Radical Ion Pairs for Quantum Sensing of Electric Fields: Effect of Electron-Nuclear Hyperfine Coupling.

J Phys Chem A

September 2025

Department of Chemistry, Institute for Quantum Information Research and Engineering, and Center for Molecular Quantum Transduction, Northwestern University, Evanston, Illinois 60208-3113, United States.

Light-driven formation of radical ion pairs that occurs much faster than their electron spin dynamics results in correlated spins whose coherence properties can be used as a quantum-based electric field sensor. This results from the radical ion pair having charge and spin distributions that track one another. Thus, electric field induced changes in the distance between the two charges are reflected in the spin-spin distance that can be measured directly using out-of-phase electron spin echo envelope modulation (OOP-ESEEM), a pulse-EPR technique.

View Article and Find Full Text PDF

A hybrid denoising method for low-field nuclear magnetic resonance data.

Magn Reson Lett

May 2025

State Key Laboratory of Petroleum Resources and Engineering, China University of Petroleum (Beijing), Beijing, 102249, China.

Low-field nuclear magnetic resonance (NMR) has broad application prospects in the exploration and development of unconventional oil and gas reservoirs. However, NMR instruments tend to acquire echo signals with relatively low signal-to-noise ratio (SNR), resulting in poor accuracy of spectrum inversion. It is crucial to preprocess the low SNR data with denoising methods before inversion.

View Article and Find Full Text PDF

Since its introduction more than 30 years ago, the blood oxygenation level-dependent (BOLD) contrast remains the most widely used method for functional MRI (fMRI) in humans and animal models. The BOLD contrast is typically acquired with echo planar imaging (EPI) to obtain sensitization of the signal during the echo time (TE) to dynamic changes in deoxyhemoglobin content, while achieving high spatiotemporal resolution and full brain coverage. However, EPI-based fMRI also faces multiple shortcomings, including sensitivity to body motion, susceptibility-related signal dropouts, interference with multimodal sensors, and loud acoustic noise.

View Article and Find Full Text PDF

Direct myelin imaging with inversion-recovery ultrashort-echo-time (IR-UTE) is highly motion-sensitive, yet extra hardware or longer scans are impractical. We evaluated whether a superior-inferior (SI) self-navigator with bit-reversed spoke-angles mitigates motion artifacts without extending acquisition. Dual-echo IR-UTE was implemented at 3T.

View Article and Find Full Text PDF

Multivariate pattern analysis (MVPA) methods are a versatile tool to retrieve information from neurophysiological data obtained with functional magnetic resonance imaging (fMRI) techniques. Since fMRI is based on measuring the hemodynamic response following neural activation, the spatial specificity of the fMRI signal is inherently limited by contributions of macrovascular compartments that drain the signal from the actual location of neural activation, making it challenging to image cortical structures at the spatial scale of cortical columns and layers. By relying on information from multiple voxels, MVPA has shown promising results in retrieving information encoded in fine-grained spatial patterns.

View Article and Find Full Text PDF