Direct count of fluorescent microspheres in a microfluidic chip based on the capillary electrophoresis method.

Anal Methods

Department of Pediatric Dentistry, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology,

Published: June 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Fluorescent microspheres (FMs) are tiny particles with special functions that are widely employed in biological research. Counting of microscale FMs is a great challenge by capillary electrophoresis. Herein we developed a method to count 2 μm FMs based on a microfluidic chip with a gradual change in inner size. Such a microfluidic chip can inhibit sample blocking at the inlet of the capillary. The results showed that FMs migrated in the wide part of the microchannel side by side, and then passed through the narrow part one by one. There was a linear relationship between the number of peaks in the electropherogram and concentration of FMs if they were running in the microchannel for more than 20 min. A high separation voltage may lead to aggregation of FMs in the microchannels, and about 2 × 10 FMs can be counted within 30 min by this microfluidic chip.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d3ay00710cDOI Listing

Publication Analysis

Top Keywords

microfluidic chip
16
fluorescent microspheres
8
capillary electrophoresis
8
fms
7
direct count
4
count fluorescent
4
microfluidic
4
microspheres microfluidic
4
chip
4
chip based
4

Similar Publications

Microfluidics-assisted spatially barcoded microarray technology offers a high-throughput, low-cost approach towards spatial transcriptomic profiling. A uniform barcoded microarray is crucial for spatially unbiased mRNA analysis. However, non-specific adsorption of barcoding reagents in microchannels occurs during liquid transport, causing non-uniform barcoding in the chip's functional regions.

View Article and Find Full Text PDF

A directional self-priming continuous-driven compartmentalized microfluidic chip for multiplexed pathogen detection.

Analyst

September 2025

Research Centre for Analytical Instrumentation, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310027, P. R. China.

Rapid and efficient screening of foodborne pathogens is crucial for preventing bacterial spread and food poisoning. However, developing a multi-detection method that is easy to operate, offers good stability, and achieves high efficiency remains an enormous challenge. Existing multiplexed nucleic acid detection methods suffer from complex designs, leading to complicated operations, and non-robust sample introduction, causing primer/probe crosstalk and false-positive results.

View Article and Find Full Text PDF

Retinal ganglion cells (RGCs) are highly compartmentalized neurons whose long axons serve as the sole connection between the eye and the brain. In both injury and disease, RGC degeneration occurs in a similarly compartmentalized manner, with distinct molecular and cellular responses in the axonal and somatodendritic regions. The goal of this study was to establish a microfluidic-based platform to investigate RGC compartmentalization in both health and disease states.

View Article and Find Full Text PDF

Statistical quantification of SERS signals in microfluidic flow using AuNP-bound polystyrene microparticles.

Anal Sci

September 2025

Department of Chemistry, Graduate School of Advanced Science and Engineering, Hiroshima University, 1-3-1 Kagamiyama, Higashi-Hiroshima, 739-8526, Japan.

Surface-enhanced Raman scattering (SERS) is a powerful analytical technique; however, its quantitative application has been limited by the instability of substrates and significant signal fluctuations. In this study, we demonstrated that 4-aminobenzenethiol (4-ATP) can be quantitatively detected through statistical analysis of SERS signal intensity distributions obtained using citrate-stabilized AuNPs, biotin-functionalized AuNPs, and gold nanoparticle (AuNP)-bound polystyrene (PS) microparticles. Raman spectra obtained in bulk aqueous solution under static conditions showed that the detection sensitivity of 4-ATP using AuNP-bound PS microparticles was approximately twice that achieved with citrate-stabilized AuNPs or biotin-modified AuNPs.

View Article and Find Full Text PDF

Tunable cell separation using a thermo-responsive deterministic lateral displacement device.

Lab Chip

September 2025

Institute of Integrated Research, Institute of Science Tokyo, R2-9, 4259 Nagatsuta-cho, Midoriku, Yokohama, Kanagawa 226-8501, Japan.

Tunability in isolating target cells of varying sizes from complex heterogeneous samples is essential for biomedical research and diagnostics. However, conventional deterministic lateral displacement (DLD) systems lack flexibility due to their fixed critical diameters (). Here, we present a thermo-responsive DLD micropillar array that enables tunable cell separation by dynamically modulating through temperature control.

View Article and Find Full Text PDF