Article Abstract

This study aimed to compare different ultrasound devices with magnetic resonance spectroscopy (MRS) to quantify muscle lipid content from echo intensity (EI). Four different ultrasound devices were used to measure muscle EI and subcutaneous fat thickness in four lower-limb muscles. Intramuscular fat (IMF), intramyocellular (IMCL) and extramyocellular lipids (EMCL) were measured using MRS. Linear regression was used to compare raw and subcutaneous fat thickness-corrected EI values to IMCL, EMCL and IMF. IMCL had a poor correlation with muscle EI (r = 0.17-0.32, NS), while EMCL (r = 0.41-0.84, < 0.05- < 0.001) and IMF (r = 0.49-0.84, < 0.01- < 0.001) had moderate to strong correlation with raw EI. All relationships were improved when considering the effect of subcutaneous fat thickness on muscle EI measurements. The slopes of the relationships were similar across devices, but there were some differences in the y-intercepts when raw EI values were used. These differences disappeared when subcutaneous fat thickness-corrected EI values were considered, allowing for the creation of generic prediction equations (r = 0.41-0.68, < 0.001). These equations can be used to quantify IMF and EMCL within lower limb muscles from corrected-EI values in non-obese subjects, regardless of the ultrasound device used.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10255973PMC
http://dx.doi.org/10.3390/s23115282DOI Listing

Publication Analysis

Top Keywords

subcutaneous fat
16
ultrasound devices
12
extramyocellular lipids
8
intramuscular fat
8
echo intensity
8
lower limb
8
limb muscles
8
devices magnetic
8
magnetic resonance
8
resonance spectroscopy
8

Similar Publications

Nutritionally Relevant Technological Advancements in Professional Cycling.

Int J Sport Nutr Exerc Metab

September 2025

Mary MacKillop Institute for Health Research, Australian Catholic University, Melbourne, VIC, Australia.

Technological innovations can provide cyclists and their support team additional data. These data have potential to improve understanding of performance determinants and could be used to identify and tailor nutritional strategies to improve cycling performance. This potential, however, is dependent on the quality, interpretation, and practical use of the data generated.

View Article and Find Full Text PDF

Background: Cryolipolysis is an effective, well-tolerated noninvasive subcutaneous fat reduction treatment.

Objective: Assess participant satisfaction, effectiveness, and safety of a dual-applicator cryolipolysis system that can deliver simultaneous treatments.

Materials And Methods: Adult participants received treatment to the abdomen/flanks (midsection).

View Article and Find Full Text PDF

Background And Aim: The search for sustainable and cost-effective protein alternatives to soybean meal in livestock diets has led to the exploration of legumes such as faba beans [FBs] ( L.). This study investigated the effects of dietary inclusion of FBs on carcass traits, meat quality, and selected blood parameters in Awassi lambs.

View Article and Find Full Text PDF

Background: Disturbances in lipid metabolism are usually associated with hyperlipidemia, which is commonly observed in donkeys with inappetence or anorexia. The diagnostic utility of ultrasound measurements of croup fat thickness (CFT) and relative liver echogenicity for lipomobilization in donkeys with fasting-induced hyperlipidemia was investigated. A prospective observational control study involving 25 donkeys was conducted, and the animals were randomly assigned to a fasting group (FG, n = 20) and a control group (CG, n = 5).

View Article and Find Full Text PDF

Objective: This study aimed to create and validate a nomogram to predict early recurrence (ER) in Colorectal cancer (CRC) patients by combining CT-derived abdominal fat parameters with clinical and pathological characteristics.

Methods: We conducted a retrospective analysis of 206 CRC patients, dividing them into training (n = 146) and validation (n = 60) cohorts. We quantified abdominal fat parameters, including subcutaneous adipose tissue index (SATI) and visceral adipose tissue index (VATI), using semi-automatic software on CT images at the level of the third lumbar vertebra (L3).

View Article and Find Full Text PDF