Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Kirschner wire (K-wire) fixation is widely used to repair metacarpal and phalangeal fractures. In this study, we simulated K-wire osteosynthesis of a 3-dimensional (3D) phalangeal fracture model and investigated the fixation strength at various K-wire diameters and insertion angles to clarify the optimal K-wire fixation method for phalangeal fractures. The 3D phalangeal fracture models were created by using computed tomographic (CT) images of the proximal phalanx of the middle finger in five young healthy volunteers and five elderly osteoporotic patients. Two elongated cylinders representing K-wires were inserted according to various cross-pinning methods; the wire diameters were 1.0, 1.2, 1.5 and 1.8 mm, and the wire insertion angles (i.e. the angle between the fracture line and the K-wire) were 30°, 45° and 60°. The mechanical strength of the K-wire fixed fracture model was investigated by using finite element analysis (FEA). The fixation strength increased with increasing wire diameter and insertion angle. Insertion of 1.8-mm wires at 60° achieved the strongest fixation force in this series. Fixation strength was generally stronger in the younger group than the elderly group. Dispersion of stress to cortical bone was a critical factor to increase fixation strength. We developed a 3D phalangeal fracture model into which we inserted K-wires; using FEA, we clarified the optimal crossed K-wire fixation method for phalangeal fractures. Level V (Therapeutic).

Download full-text PDF

Source
http://dx.doi.org/10.1142/S2424835523500169DOI Listing

Publication Analysis

Top Keywords

fixation strength
16
k-wire fixation
12
phalangeal fractures
12
phalangeal fracture
12
fracture model
12
finite element
8
element analysis
8
mechanical strength
8
fixation
8
model investigated
8

Similar Publications

Background: Acetabular reconstruction is often challenging in revision hip arthroplasty, especially in the face of moderate to severe acetabular bone deficiency. In some severe bone defects, double-metal tantalum cups can improve the contact area between bone and implants, increase the surface area for bone ingrowth, and better restore the anatomical position of the acetabulum. Furthermore, with a good press-fit, the auxiliary screw has a minimal effect on acetabular cup stability.

View Article and Find Full Text PDF

Editing a gibberellin receptor gene improves yield and nitrogen fixation in soybean.

J Integr Plant Biol

September 2025

State Key Laboratory of Crop Genetics & Germplasm Enhancement and Utilization, Zhongshan Biological Breeding Laboratory, National Center for Soybean Improvement, National Innovation Platform for Soybean Breeding and Industry-Education Integration, Key Laboratory for Biology and Genetic Improvement o

Soybean is an important source of oil, protein, and feed. However, its yield is far below that of major cereal crops. The green revolution increased the yield of cereal crops partially through high-density planting of lodging-resistant semi-dwarf varieties, but required more nitrogen fertilizers, posing an environmental threat.

View Article and Find Full Text PDF

Introduction: Patients with hemifacial microsomia exhibit varying degrees of mandibular asymmetry. The commercial plates used during bilateral sagittal split osteotomy (BSSO) surgery are often not tailored to individual patients and may lack sufficient fixation stability, increasing the risk of mandibular relapse. This study proposes a patient-specific plate design by collecting CT images of 30 cases of hemifacial microsomia to statistically analyze mandibular asymmetry.

View Article and Find Full Text PDF

This study presents a comprehensive framework combining Selective Laser Melting (SLM) of Titanium (Ti64) alloys, finite element simulation, and artificial intelligence (AI) to advance orthopedic implants' design and predictive evaluation. Dense Ti64 specimens are fabricated using ten distinct SLM parameter sets to explore the effects of volumetric energy density (VED) on mechanical behavior, porosity distribution, and microstructural integrity. Optimal VED ranges are identified to balance defect minimization and mechanical performance, with porosity levels strongly influencing tensile strength and Young's modulus.

View Article and Find Full Text PDF

Background: Spinal metastases frequently cause neurological compromise and mechanical instability. Titanium fixation limits postoperative imaging and hinders stereotactic body radiotherapy (SBRT) planning because of artefacts.

Methods: CARBOMETASPINE is a multicentre, prospective, randomised controlled trial.

View Article and Find Full Text PDF