Article Abstract

Objective: The aim of this study is to investigate the radiation dose and image quality of head CT using SPS and OBTCM techniques.

Methods: Three anthropomorphic head phantoms (1-yr-old, 5-yr-old, and adult) were used. Images were acquired using four modes (Default protocol, OBTCM, SPS, and SPS+OBTCM). Absorbed dose to the lens, anterior brain (brain_A), and posterior brain (brain_P) was measured and compared. Image noise and CNR were assessed in the selected regions of interest (ROIs).

Results: Compared with that in the Default protocol, the absorbed dose to the lens reduced by up to 28.33%,71.38%, and 71.12% in OBTCM, SPS, and SPS+OBTCM, respectively. The noise level in OBTCM slightly (≤1.45HU) increased than that in Default protocol, and the SPS or SPS+OBTCM mode resulted in a quantitatively small increase (≤2.58HU) in three phantoms. There was no significant difference in CNR of different phantoms under varies scanning modes (p > 0.05).

Conclusions: During head CT examinations, the SPS mode can reduce the radiation dose while maintaining image quality. SPS+OBTCM couldn't further effectively reduce the absorbed dose to the lens for 1-yr and 5-yr-old phantoms. Thus, SPS mode in pediatric and SPS+OBTCM mode in adult are better than other modes, and should be used in clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.3233/XST-230018DOI Listing

Publication Analysis

Top Keywords

radiation dose
12
default protocol
12
sps sps+obtcm
12
absorbed dose
12
dose lens
12
image quality
8
obtcm sps
8
sps+obtcm mode
8
sps mode
8
dose
6

Similar Publications

Gamma and X-ray radiation on mating and sperm transfer in sterile Anastrepha ludens (Diptera: Tephritidae).

J Econ Entomol

September 2025

Departamento de Ecología de Artrópodos y Manejo de Plagas, El Colegio de la Frontera Sur, Tapachula, Chiapas, Mexico.

Ionizing radiation is widely used in insect sterilization for pest control using the Sterile Insect Technique, which consists of the mass rearing of insects and their irradiation with gamma rays to release them in target areas where they will mate with wild females. However, there is a concern and controversy about the nuclear origin applied in this technique. One alternative for sterilization is the use of X-rays, which do not have a nuclear origin, are easier to operate, and do not generate radioactive waste.

View Article and Find Full Text PDF

Background: Among childhood cancer survivors, germline rare variants in autosomal dominant cancer susceptibility genes (AD CSGs) could increase subsequent neoplasm (SNs) risks, but risks for rarer SNs and by age at onset are not well understood.

Methods: We pooled the Childhood Cancer Survivor Study and St Jude Lifetime Cohort (median follow-up = 29.7 years, range 7.

View Article and Find Full Text PDF

Volumetric modulated arc therapy (VMAT) for lung cancer involves complex multileaf collimator (MLC) motion, which increases sensitivity to interplay effects with tumour motion. Current dynamic conformal arc methods address this issue but may limit the achievable dose distribution optimisation compared with standard VMAT. This study examined the clinical utility of a VMAT technique with monitor unit limits (VMATliMU) to mimic conformal arc delivery and reduce interplay effects while maintaining plan quality.

View Article and Find Full Text PDF

Unlabelled: Passive Acoustic Mapping (PAM) is rapidly emerging as a ubiquitous tool for real-time localization and monitoring of therapeutic ultrasound treatments involving cavitation in the context of safety or efficacy. The ability of PAM to spatially quantify and resolve cavitation activity offers a unique opportunity to correlate the energy of cavitation phenomena with locally observed bioeffects.

Objective: We aim to develop methods of measuring and reporting spatio-temporally varying cavitation energies that are energy-preserving, device-independent, and adequately normalized to the volume of tissue being affected by the reported cavitation activity.

View Article and Find Full Text PDF

Essentials of the System of Radiological Protection.

J Radiol Prot

September 2025

Centre for Radiation Protection Research, Stockholm University, Svante Arrheniusväg 20C, 106 91 Stockholm, Sweden.

The System of Radiological Protection (the "System") developed by the International Commission on Radiological Protection (ICRP) is built on nearly a century of efforts of numerous scientists and practitioners working together internationally. It rests on three enduring pillars: science, ethics, and experience. These pillars support the three fundamental principles that shape radiological protection strategies: justification, optimisation, and application of dose limits.

View Article and Find Full Text PDF