Current guidelines recommend delaying noncardiac surgery for 6 months after drug eluting stent implantation. However, this recommendation is largely based on limited evidence and various event definitions. Whether early surgery within 6 months of coronary stent implantation increases myocardial injury in patients with normal preoperative high-sensitivity cardiac troponin I (hs-cTnI) has not yet been investigated. This retrospective study assessed patients who received coronary stent implantation and underwent noncardiac surgery (vascular, abdominal, or thoracic) between 2010 and 2017 with normal preoperative hs-cTnI (n = 186). Patients were divided into early (within 6 months of PCI) and late (after 6 months of PCI) groups. The primary endpoint was the incidence of myocardial injury as diagnosed by hs-cTnI within 3 days post-operation. The secondary outcomes were myocardial infarction, stent thrombosis, emergent coronary revascularization, major bleeding (bleeding requiring transfusion or intracranial bleeding), stroke, renal failure, heart failure, or death within 30 days post-operation. Inverse probability treatment weighting (IPTW) was carried out to adjust for the intergroup baseline differences. Myocardial injury occurred in 28.6% (8/28) and 27.8% (44/158) of the early and late groups, respectively, with no difference between groups (odds ratio [OR] 1.067, 95% confidence interval [CI] 0.404, 2.482; = 0.886). Secondary outcomes did not differ between the groups. IPTW analysis also showed no differences in myocardial injury and secondary outcomes between the groups. In conclusion, early surgery within 6 months after coronary stent implantation did not increase the incidence of myocardial injury in patients with normal preoperative hs-cTnI.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10095235 | PMC |
http://dx.doi.org/10.3390/jcm12072524 | DOI Listing |
Interv Neuroradiol
September 2025
Department of Neuroradiology, Walton Centre for Neurology and Neurosurgery, Liverpool, UK.
ObjectiveThis study aims to determine the outcomes of nickel allergic patients who underwent a trial of forearm arterial stenting with a nickel-based stent, with follow-up to assess for an allergic reaction. In the absence of adverse effects, patients had their intracranial aneurysm treatment with a nickel-based cerebrovascular device.MethodsA retrospective analysis was performed on patients who had an allergy to nickel, with an intracranial aneurysm who underwent treatment with a permanently implanted nickel-containing device.
View Article and Find Full Text PDFAdv Healthc Mater
September 2025
Department of Biomedical Engineering, University of Houston, Houston, TX, 77204, USA.
Neurogenic bladder and lower urinary tract (LUT) dysfunctions encompass a wide variety of urinary disorders resulting from nervous system impairments. Unfortunately, conventional treatments are still limited and can have significant complication rates, especially when stent implantations or other surgical procedures are involved. Therefore, there is a critical need to develop novel therapeutic strategies and pharmacological approaches to address these challenging urological conditions.
View Article and Find Full Text PDFRegen Biomater
August 2025
Shi-Changxu Innovation Center for Advanced Materials, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China.
The most significant challenge facing magnesium alloy stents is their ability to withstand complex deformation during their application. To gain a deeper understanding of the impact of stent deformation on the protective capabilities of the coating, this paper presents an amplified stent deformation model. The models were coated with either a low elongation material-Poly(D, L-lactide) (PDLLA) or a high elongation material-Poly(butylene adipate-co-terephthalate) (PBAT), followed by the application of a rapamycin-loaded PLGA as drug-eluting layer.
View Article and Find Full Text PDFEur Heart J Case Rep
September 2025
GNH Klinikum Kassel, Center for Cardiac Care, Mönchebergstraße 41-45, Kassel 34125, Germany.
Background: Pacemaker implantation has become a routine procedure in contemporary cardiology. Several possible complications during and after the procedure have been described, with this article focusing on the rare complication and the prevention of left-sided lead placement after arterial puncture.
Case Summary: A 90-year-old female patient was admitted to our hospital due to recurrent transient ischaemic attacks following a dual-chamber pacemaker implantation six weeks earlier.
Am J Ophthalmol Case Rep
September 2025
Columbia University Medical Center, Norwalk, Connecticut, USA.
Purpose: To report a surgical treatment for neovascular angle closure glaucoma.
Observations: A 69 year-old man with proliferative diabetic retinopathy developed neovascular angle closure with intraocular pressure (IOP) 60 mm Hg. Surgical goniosynechialysis and placement of a Hydrus canalicular stent were combined with pupilloplasty using an iris cerclage suture to maintain tension on the peripheral iris to limit reformation of goniosynechiae.