98%
921
2 minutes
20
Introduction: Long-term spinal stability after total en bloc spondylectomy (TES) is challenging. The aim of this study was to examine whether the new method could reduce the incidence of instrumentation failure (IF).
Methods: We retrospectively compared 116 patients with spinal tumors who underwent TES between 2010 and 2019 and were followed up for >1 year. IF, cage subsidence, and complications were evaluated. Propensity score matching between conventional and new method groups was performed for age, sex, body mass index, preoperative radiotherapy, number of resected vertebrae, number of instrumented vertebrae, tumor level, and follow-up period. There were 25 cases each in the conventional and new method groups. The conventional method used a titanium mesh cage for anterior reconstruction and 5.5-mm-diameter titanium alloy rods for posterior fixation. The new method used a more robust cage for anterior reconstruction, bone grafting was performed around the cage, and 6.0-mm-diameter cobalt chromium rods were used for posterior fixation. We compared the incidence of IF and cage subsidence after TES between the conventional and new method groups.
Results: While 5 out of 25 patients (20.0%) in the conventional method group experienced IF, none from the new method group experienced IF. Three-year implant survival rates were 87.3% in the conventional and 100% in the new method groups. The new method group had a significantly higher implant survival rate (p<0.01). Cage subsidence was observed in 11 of 25 (44/0%) patients in the conventional method and 1 of 25 (4.0%; significantly lower, p<0.05) in the new method group.
Conclusions: The new reconstruction method significantly reduced IF incidence in patients with TES.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9931410 | PMC |
http://dx.doi.org/10.22603/ssrr.2022-0111 | DOI Listing |
Wounds
August 2025
Faculty of Physical Therapy, Cairo University, Cairo, Giza, Egypt.
Background: Charcot foot is a debilitating complication of peripheral neuropathy and is primarily associated with diabetes, leading to structural damage, ulceration, and osteomyelitis. Pulsed electromagnetic field (PEMF) therapy is a promising treatment modality for wound healing and bone metabolism.
Objective: To evaluate the efficacy of PEMF therapy in promoting bone growth and ulcer healing in patients with Charcot foot ulcers.
BMC Med Educ
September 2025
Department of Prosthodontics, University of Würzburg, Pleicherwall 2, 97070, Würzburg, Germany.
Background: Bridge preparation skills are a vital component of dental education and require specific techniques. This study aimed to develop and evaluate 3D printed teeth for use in defect-oriented bridge preparation and pre-prosthetic exercises in dental training, addressing the limited customization and lack of integrated workflows found in commercial typodont teeth. The null hypothesis stated that 3D printed teeth offered no advantage over established typodont training methods for bridge preparation.
View Article and Find Full Text PDFMAGMA
September 2025
Department of Medical Imaging, (766), Radboud University Medical Center, Geert Grooteplein 10Radboudumc, P.O. Box 9101, 6500 HB, Nijmegen, the Netherlands.
Objective: To improve B field homogeneity in prostate MR imaging and spectroscopy using a custom-designed 16-channel external local shim coil array.
Methods: In vivo prostate imaging was performed in seven healthy volunteers (mean age: 40.7 years) without bowel preparation.
Anal Bioanal Chem
September 2025
School of Artificial Intelligence, Hangzhou Dianzi University, Hangzhou, 310018, China.
The prompt and accurate identification of pathogenic bacteria is crucial for mitigating the transmission of infections. Conventional detection methods face limitations, including lengthy processing, complex sample pretreatment, high instrumentation costs, and insufficient sensitivity for rapid on-site screening. To address these challenges, an aptamer (Apt)-sensor based on functionalized magnetic nanoparticles (MNPs) was developed for detecting Escherichia coli.
View Article and Find Full Text PDFSurg Endosc
September 2025
Department of Next Generation Endoscopic Intervention (Project ENGINE), Graduate School of Medicine, The University of Osaka, Suite 0802, BioSystems Bldg., 1-3, Yamadaoka, Suita, Osaka, 565-0871, Japan.
Objective: Rigid suction-coagulation probes constrain the wrist-like articulation that is central to robotic surgery. We therefore designed a 5-mm single-use flexible suction ball coagulator (flex-SBC) with a modified core design to restore dexterity and assessed its mechanical performance and early clinical feasibility, including the effect of the common robotic gripping strategies on suction flow.
Methods: Preclinical.