Article Abstract

Purpose: Angle kappa has been considered to play a role in causing glare and haloes despite accurate centration during implantation of multifocal intraocular lenses following phacoemulsification. There is a lack of substantial data regarding whether angle kappa is a constant entity or changes following ocular surgical procedures. To answer this question, in this prospective observational study, we measured change in angle kappa following phacoemulsification, and studied the ocular biometric parameters correlating with this change.

Methods: Angle kappa was measured objectively using synoptophore. Ocular Biometric parameters (Anterior Chamber Depth, Corneal White-to-White measurement, Lens Thickness, and Axial Length) using LenStar LS 900 Haag Streit Anterior Segment imaging system. outcome measures were a quantitative change in angle kappa from the preoperative value by one degree or more and observation of correlation between change in angle kappa and ocular biometric parameters. The Wilcoxin Signed Rank Test was used to determine the difference between pre-operative and post-operative measurements for angle kappa. A p-value of less than 0.05 was considered statistically significant. Pearson's correlation coefficient was employed to find the relationship between preoperative ocular biometric parameters and a change in angle kappa. A linear regression model was used to derive an equation considering corneal white-to-white measurement as the predictor and change in angle kappa as the outcome measure.

Results: A significant change in angle kappa was recorded, and a significant correlation was found with corneal white to white measurements. This change could be predicted preoperatively, for a known corneal white to white measurement using the standard equation y=mx+c.

Conclusion: This study explains the possible cause of dissatisfaction among seemingly ideal patients who undergo multifocal IOL implantation and the potential for better decision-making during patient selection for multifocal IOL implantation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10228972PMC
http://dx.doi.org/10.4103/ijo.IJO_1641_22DOI Listing

Publication Analysis

Top Keywords

angle kappa
44
change angle
28
ocular biometric
20
biometric parameters
20
angle
11
kappa
11
corneal white-to-white
8
white-to-white measurement
8
corneal white
8
white white
8

Similar Publications

The helical morphology of Type B aortic dissections (TBAD) represents a potentially important geometric biomarker that may influence dissection progression. While three-dimensional surface-based quantification methods provide accurate TBAD helicity assessment, their clinical adoption remains limited by significant processing time. We developed and validated a clinically practical centerline-based helicity quantification method using routine imaging software (TeraRecon) against an extensively validated surface-based method (SimVascular).

View Article and Find Full Text PDF

Intraocular lens power calculation in post-myopic-LASIK eyes: comparison of two different corneal refractive power measurements by Pentacam.

Eye (Lond)

September 2025

Department of Ophthalmology, Shanghai Key Laboratory of Visual Impairment and Restoration, Eye and ENT Hospital, Fudan University, Shanghai, China.

Objectives: To compare the accuracy of two different corneal refractive power measurements in intraocular lens (IOL) power calculation in post-myopic-LASIK eyes.

Methods: Post-myopic-LASIK patients scheduled for cataract surgery were enrolled. Corneal refractive power centred on corneal apex (K) and pupil centre (K), decentration of ablation zone, and Kappa angle were measured by Pentacam.

View Article and Find Full Text PDF

The title complex, [Fe(CHN)(CHN)]·3CH, possesses inversion symmetry with the iron(II) atom located on a center of symmetry. The metal atom is coordinated in a symmetric octa-hedral geometry by four pyrrole N atoms of the porphyrin ligand in the equatorial plane and two N atoms of 1-methyl-imidazole ligands in the axial sites; the complex crystallizes with three toluene solvent mol-ecules. The average Fe-N (N is a porphyrin N atom) bond length is 1.

View Article and Find Full Text PDF

Background: Screw fixation is pivotal for prosthetic stability. For 3D-printed customized acetabular revision prostheses designed for complex, large-scale bone defects, precise adherence to preoperative screw trajectory planning is critical. However, there remains a lack of standardized three-dimensional (3D) evaluation protocols to quantify intraoperative screw angular alignment fidelity relative to preoperative digital plans, hindering universal validation criteria.

View Article and Find Full Text PDF

Introduction: This study explores the potential of artificial intelligence (AI) to enhance the accuracy and efficiency of video review systems in Taekwondo, addressing limitations in current human-based judgment processes during competitions.

Methods: A total of 241 video review cases from the 2024 Paris Olympic Taekwondo competition were analyzed. AI-based judgments were generated using ChatGPT-4.

View Article and Find Full Text PDF