Article Abstract

To define the influence of air, SF6 gas and silicon oil 1000cs tamponade injection and oil tamponade removal on corneal biomechanics, central corneal thickness and intraocular pressure. 77 eyes referred to vitrectomy were divided into 4 groups: 19 to air tamponade, 21 to SF6 tamponade, 19 to oil tamponade, 18 to oil tamponade removal. Pre- and postoperative corneal hysteresis, corneal resistance factor, corneal thickness, Goldman intraocular pressure (GAT) and corneal compensated intraocular pressure (IOPcc) were analysed. GAT and IOPcc did not change after the air or SF6 tamponade. The oil tamponade injection caused increase in GAT and IOPcc, while the oil removal caused reduction in those parameters. In all groups, preoperative and postoperative values of GAT and IOPcc did not differ. There was no change in corneal thickness and biomechanics after air, SF6 or oil tamponade while after removal of oil those parameters are decreased. The air, SF6 and oil tamponade does not change the corneal thickness and corneal biomechanics. The removal of oil causes decrease in corneal thickness and biomechanics which can lead to bias in intraocular pressure measurement. GAT and IOPcc did not differ in eyes pre- and post-vitrectomy, being similarly reliable measure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9813351PMC
http://dx.doi.org/10.1038/s41598-023-27407-8DOI Listing

Publication Analysis

Top Keywords

corneal thickness
24
oil tamponade
24
intraocular pressure
20
air sf6
16
gat iopcc
16
corneal
12
tamponade removal
12
tamponade oil
12
oil
10
tamponade
10

Similar Publications

Peripheral vitreoretinal abnormality and its correlation with malignant glaucoma in nanophthalmos with secondary angle closure glaucoma.

Eye (Lond)

September 2025

Beijing Tongren Eye Center Research Ward, Beijing Tongren Hospital, Beijing Institute of Ophthalmology, Beijing Ophthalmology & Visual Sciences Key Laboratory, Capital Medical University, Beijing, China.

Background: To evaluate the peripheral vitreoretinal abnormality (PVA) and its correlation with the risk of malignant glaucoma (MG) in nanophthalmos with secondary angle closure glaucoma (NSACG).

Methods: This prospective case series included 47 NSACG eyes with axial length (AL) < 21 mm from 25 patients. PVA was defined as a hyperreflective echo at the peripheral vitreoretinal region under ultrasound biomicroscopy (UBM).

View Article and Find Full Text PDF

Pseudomonas aeruginosa (PA) represents a major cause of antimicrobial resistance-related morbidity and mortality. The recent emergence of highly fatal infections, caused by carbapenem-resistant PA, has called for novel antimicrobial therapies and strategies. In this study, we highlight the therapeutic potential of ε-poly-L-lysine (εPL), an antimicrobial polymer for treating extensively-and pan-drug-resistant-PA.

View Article and Find Full Text PDF

Differences in the Corneal Biomechanical Responses to LASIK and KLEx Based on Parametric Numerical Simulation.

J Refract Surg

September 2025

From National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, China.

Purpose: To use parametric numerical simulation to characterize and compare the differences in corneal biomechanical responses to laser in situ keratomileusis (LASIK) and keratorefractive lenticule extraction (KLEx) under various surgical settings.

Methods: The Finite Element Model was used in a parametric study to evaluate corneal biomechanical responses to LASIK and KLEx, considering variations in preoperative corneal thickness, corneal flap/cap thickness and diameter, refractive correction, and optical zone diameter. Surgery-induced stress, displacement, and interface contact pressure were compared between LASIK and KLEx using the Wilcoxon signed-rank test.

View Article and Find Full Text PDF

Purpose: To assess differences in intraocular lens (IOL) power calculation prediction error (PE) considering the manufacturing tolerance or exact power (EP) versus labeled power (LP), and to compare accuracy using the Barrett formula with optimized constant versus a thick-lens formula.

Methods: The PE and absolute PE were calculated for a random eye of patients implanted with the multifocal Liberty Q-Flex 640PM IOL (Medicontur Ltd) considering the LP and the EP provided by the manufacturer. The outcomes for the Barrett with optimized constant formula and a thick-lens formula personalized for the surgeon, biometer, and IOL were compared.

View Article and Find Full Text PDF

To summarize the evidence examining the outcomes of Descemet membrane endothelial keratoplasty (DMEK) using eye bank pre-stripped versus surgeon prepared grafts. Systematic review and meta-analysis. This study was conducted following the preferred reporting items for systematic reviews and meta-analyses consensus statement (PROSPERO ID: CRD42023457120).

View Article and Find Full Text PDF