A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

An innovative single-base extension method for synchronous detection of point mutations and MSI status in colorectal cancer. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: An accurate genotyping analysis is one of the critical prerequisites for patients with colorectal cancer receiving matched therapies. Conventional genotyping analysis is currently used to detect either gene mutations or MSI status, delaying the detection of critical tumor biomarkers and thus the optimal time for treatment. An assay that analyzes both biomarkers in a streamlined process is eagerly needed.

Methods: We developed an assay combining Multiplex PCR Amplification, Single-base Extension and capillary electrophoresis (CE) analysis (MASE-CE) for synchronous detection of KRAS/NRAS/BRAF mutations and MSI status. In a 190 colorectal cancer cohort, we identified seven somatic mutations in KRAS, NRAS and BRAF as well as five MSI loci (D2S123/D5S346/D17S250/BAT-25/BAT-26) simultaneously. KRAS/NRAS/BRAF mutations were detected by NGS and MASE-CE, and MSI status were detected by PCR-CE and MASE-CE methods.

Results: The MASE-CE method showed high consistency with NGS for mutation detection (Kappa value ≥0.8) and PCR-CE (Kappa value = 0.79). In addition, the limits of detection (LOD) of MASE-CE assay for MSI and somatic mutation were 5% and 2%, respectively.

Conclusions: In somatic mutation detection and MSI detection, the LOD of MASE-CE assay was superior to that of qPCR and NGS. MASE-CE assay is a highly sensitive, time-saving and specimen-saving method, which can greatly avoid the cumbersome testing process and provide clinical decision for doctors in time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10134345PMC
http://dx.doi.org/10.1002/cam4.5557DOI Listing

Publication Analysis

Top Keywords

msi status
16
mutations msi
12
colorectal cancer
12
mase-ce assay
12
single-base extension
8
synchronous detection
8
genotyping analysis
8
kras/nras/braf mutations
8
ngs mase-ce
8
mutation detection
8

Similar Publications