5-Fluorouracil-Immobilized Hyaluronic Acid Hydrogel Arrays on an Electrospun Bilayer Membrane as a Drug Patch.

Bioengineering (Basel)

Division of Mechanical and Biomedical, Mechatronics and Materials Science and Engineering, College of Art, Culture and Engineering, Kangwon National University, Kangwondaehak-gil, Chuncheon-si 24341, Kangwon-do, Republic of Korea.

Published: November 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The hyaluronic acid (HA) hydrogel array was employed for immobilization of 5-fluorouracil (5-FU), and the electrospun bilayer (hydrophilic: polyurethane/pluronic F-127 and hydrophobic: polyurethane) membrane was used to support the HA hydrogel array as a patch. To visualize the drug propagating phenomenon into tissues, we experimentally investigated how FITC-BSA diffused into the tissue by applying hydrogel patches to porcine tissue samples. The diffusive phenomenon basically depends on the FITC-BSA diffusion coefficient in the hydrogel, and the degree of diffusion of FITC-BSA may be affected by the concentration of HA hydrogel, which demonstrates that the high density of HA hydrogel inhibits the diffusive FITC-BSA migration toward the low concentration region. YD-10B cells were employed to investigate the release of 5-FU from the HA array on the bilayer membrane. In the control group, YD-10B cell viability was over 98% after 3 days. However, in the 5-FU-immobilized HA hydrogel array, most of the YD-10B cells were not attached to the bilayer membrane used as a scaffold. These results suggest that 5-FU was locally released and initiated the death of the YD-10B cells. Our results show that 5-FU immobilized on HA arrays significantly reduces YD-10B cell adhesion and proliferation, affecting cells even early in the cell culture. Our results suggest that when 5-FU is immobilized in the HA hydrogel array on the bilayer membrane as a drug patch, it is possible to control the drug concentration, to release it continuously, and that the patch can be applied locally to the targeted tumor site and administer the drug in a time-stable manner. Therefore, the developed bilayer membrane-based HA hydrogel array patch can be considered for sustained release of the drug in biomedical applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9774285PMC
http://dx.doi.org/10.3390/bioengineering9120742DOI Listing

Publication Analysis

Top Keywords

hydrogel array
20
bilayer membrane
16
yd-10b cells
12
hydrogel
10
hyaluronic acid
8
acid hydrogel
8
electrospun bilayer
8
membrane drug
8
drug patch
8
array patch
8

Similar Publications

Enzymatic deoxyribonucleic acid (DNA) synthesis (EDS) is an environmentally friendly approach capable of generating longer and more complex sequences than chemical synthesis, making it a promising next-generation technology for high-throughput single-stranded DNA production. However, precise sequence control at high throughput remains a key challenge. Here, we present a novel electronically controlled deprotection chemistry (ECDC) integrated with a hydrogel-primer modification system on-chip for efficient multiplexed EDS.

View Article and Find Full Text PDF

A self-healing micellar hydrogel system for controlled release of caffeic acid phenethyl ester and durable inhibition of prostate tumor.

Int J Biol Macromol

September 2025

Institute of Cellular and System Medicine, National Health Research Institutes, Miaoli 35053, Taiwan; PhD Program for Aging and Graduate Institute of Basic Medical Science, China Medical University, Taichung City 40402, Taiwan; Biotechnology Center, National Chung Hsing University, Taichung City 402

Hydrogel-encapsulation allows slow and stable delivery of drugs with short half-lives, avoiding the undesired side effects of high-dose or frequent administration of drugs. We previously reported that gavage or injection of caffeic acid phenethyl ester (CAPE) at 10-15 mg/kg, 2-3 times per week effectively repressed the tumor growth of human prostate xenografts in nude mice. However, daily oral or injectable delivery of CAPE in prostate cancer (PCa) patients may be impractical due to forgetfulness, physical limitations, or treatment fatigue.

View Article and Find Full Text PDF

Organotypic 3D tissue models require precise electrophysiological interfaces to study function and disease. Multi-electrode arrays (MEAs) are essential for recording and stimulation, yet conventional fabrication methods are costly and time-intensive. This study demonstrates aerosol jet printing (AJP) of gold nanoparticles onto flexible polyimide substrates to produce fully gold, biocompatible MEAs for rapid customization of MEAs.

View Article and Find Full Text PDF

Design principles for construction of DNA-based nanostructures.

Adv Drug Deliv Rev

September 2025

Department of Chemistry, Purdue University, West Lafayette 47907, IN 47907, USA. Electronic address:

DNA nanotechnology, a cutting-edge field that constructs sophisticated DNA-based nanostructures by harnessing the unparalleled programmability of DNA, has evolved into a powerful tool for applications in therapy, biosensing, logic computation, and more. This review outlines the fundamental strategies for constructing DNA nanostructures, beginning with the design of basic building blocks such as small, symmetric tiles (e.g.

View Article and Find Full Text PDF

Scalable Photonic Crystal Sensors and Arrays Integrating Power-Free Display Interface With Dual-Mode Optical/Electrical Feedback for Real-Time Physiological Analysis.

Adv Healthc Mater

September 2025

School of Chemistry and Chemical Engineering, Guangdong Provincial Key Lab of Green Chemical Product Technology, South China University of Technology, Guangzhou, 510640, P. R. China.

Photonic crystal (PC) hydrogel-based sensors with visual signal outputs have attracted attention for wearable motion monitoring, but current devices suffer from low spatial resolution, small-scale design, and poor signal consistency. Herein, we present a combined and scalable PC sensing platform that includes a single-point sensor (100 × 400 mm) and an 8 × 8 multipixel array (100 × 100 mm) for dual-mode visual-electrical feedback. The array achieves 2D strain mapping on the arm with a spatial resolution of 0.

View Article and Find Full Text PDF