Background: To assess the efficacy of toric intraocular lenses (IOLs) in combined cataract and minimally invasive glaucoma surgery (MIGS), visual and refractive outcomes were compared between eyes implanted with non-toric and toric IOLs during iStent triple procedures.
Methods: In this retrospective study, open angle glaucoma eyes with preexisting corneal astigmatism of -1.5 diopter (D) or more and implanted with non-toric (n = 9) or toric (n = 9) IOLs were included. The main outcome measures were the intergroup difference in the uncorrected visual acuity (UCVA) and refractive astigmatism at 3 months postoperatively.
Results: Preoperatively, the logarithm of the minimum angle of resolution (logMAR) UCVAs and refractive astigmatism were equivalent between the groups. Postoperatively, the logMAR UCVA (non-toric, 0.45 ± 0.31; toric, 0.14 ± 0.15; P = 0.021) was significantly better and the refractive astigmatism (non-toric, -2.03 ± 0.63 D; toric, -0.67 ± 0.53 D; P = 0.0014) significantly less in the toric group. The toric group had postoperative improvements in the logMAR UCVA (-0.21, P = 0.020) and refractive astigmatism (+ 1.72 D, P = 0.0039). Vector analyses showed the postoperative centroid magnitude and confidence eclipses of refractive astigmatism was less in the toric group (0.47 D at 173°±0.73D) than the non-toric group (1.10 D at 2°±1.91D). Postoperatively, 78% of eyes in the toric group had 1.0 D or less refractive astigmatism compared with 11% in the non-toric group. Surgically induced astigmatism (non-toric, 0.18 D at 65°; toric, 0.29 D at 137°) did not differ between groups.
Conclusion: Use of toric IOLs is a reasonable option for better visual outcomes when the combined cataract and iStent surgery is performed in glaucomatous eyes with corneal astigmatism.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9749338 | PMC |
http://dx.doi.org/10.1186/s12886-022-02707-1 | DOI Listing |
J Refract Surg
September 2025
The College of Medicine, Taibah University, Medina, Saudi Arabia.
Purpose: To present a case of synthetic intrastromal corneal ring segment (ICRS) intrusion secondary to necrosis and migration, managed by implantation of corneal allogenic intrastromal ring segments (CAIRS) within the preexisting tunnel.
Methods: A 24-year-old man with known keratoconus underwent bilateral ICRS implantation. He presented with blurred vision in the right eye 6 weeks after the procedure.
J Refract Surg
September 2025
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Purpose: To evaluate axis-dependent visual and refractive outcomes of small incision lenticule extraction (SMILE) in patients with interocular astigmatic axis discordance.
Methods: Seventy-five patients (150 eyes) with interocular astigmatic axis discordance were included in the study. Based on interocular axis combinations, patients were stratified into three cohorts: with-the-rule (WTR)/against-the-rule (ATR) (n = 19), WTR/oblique astigmatism (OA) (n = 39), and ATR/OA (n = 17).
J Refract Surg
September 2025
Purpose: To discuss the technique and outcome of what the authors called the "flap-in-flap" technique and report its safety as a procedure for correction of post-laser in situ keratomileusis (LASIK) myopic regression.
Methods: Seven eyes of 4 patients were included in this study. All patients had previously undergone LASIK for compound myopic astigmatism using the Moria M2 micro-keratome (Moria) 8 to 12 years prior to presentation.
Purpose: To evaluate visual and refractive outcomes, visual quality, patient satisfaction, and spectacle independence 3 months after phacoemulsification with bilateral non-diffractive enhanced depth of focus (EDOF) lens implantation.
Methods: This study included 68 eyes of 34 consecutive patients, with 51.5% undergoing refractive lens exchange and 48.
J Refract Surg
September 2025
From the Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany and.
Purpose: To evaluate intraocular lens (IOL) power calculation of a non-diffractive extended depth of focus (EDOF) IOL after myopic laser in situ keratomileusis (LASIK) without historical data.
Methods: In this consecutive case series, patients who had undergone lens surgery with implantation of a non-diffractive EDOF IOL after myopic laser in situ keratomileusis (LASIK) at the Department of Ophthalmology, University Hospital Frankfurt, Frankfurt, Germany, were included. Preoperative assessments included biometry and tomography using Scheimpflug technology (Pentacam; Oculus Optikgeräte GmbH).