Article Abstract

Background: "Spin" refers to a manipulation of language that implies benefit for an intervention when none may exist. Randomized controlled trials (RCTs) in other fields have been demonstrated to employ spin, which can mislead clinicians to use ineffective or unsafe interventions. This study's objective was to determine the strategies, severity, and extent of spin in plastic surgery RCTs with nonsignificant primary outcomes.

Methods: A literature search of the top 15 plastic surgery journals using MEDLINE was performed (2000 through 2020). Parallel 1:1 RCTs with a clearly identified primary outcome showing statistically nonsignificant results ( P > 0.05) were included. Screening, data extraction, and spin analysis were performed by two independent reviewers. The spin analysis was then independently assessed in duplicate by two plastic surgery residents with graduate-level training in clinical epidemiology.

Results: From 3497 studies identified, 92 RCTs were included in this study. Spin strategies were identified in 78 RCTs (85%), including 64 abstracts (70%) and 77 main texts (84%). Severity of spin was rated moderate or high in 43 abstract conclusions (47%) and 42 main text conclusions (46%). The most identified spin strategy in the abstract was claiming equivalence for statistically nonsignificant results (26%); in the main text, focusing on another objective (24%).

Conclusions: This study suggests that 85% of statistically nonsignificant RCTs in plastic surgery employ spin. Readers of plastic surgery research should be aware of strategies, whether intentional or unintentional, used to manipulate language in reports of statistically nonsignificant RCTs when applying research findings to clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1097/PRS.0000000000009937DOI Listing

Publication Analysis

Top Keywords

plastic surgery
24
statistically nonsignificant
20
randomized controlled
8
controlled trials
8
nonsignificant primary
8
spin
8
employ spin
8
spin analysis
8
identified rcts
8
main text
8

Similar Publications

Efficacy and Safety of Hydrodissection-based Capsulectomy for Improving Cervical Mobility and Appearance After Expanded Flap Transfer.

J Craniofac Surg

September 2025

Scar and Wound Treatment Center, Plastic Surgery Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China.

An expander capsule is a fibrous membrane that forms around an expander after tissue expansion. However, whether the capsule should be removed after the expander is removed remains controversial. The authors aimed to investigate the efficacy and safety of cervical capsulectomy for improving neck mobility and appearance after expanded flap transfer.

View Article and Find Full Text PDF

Background: Spring-mediated cranioplasty (SMC) is a safe and effective treatment for craniosynostosis. The authors describe the largest cohort of endoscopic SMC for coronal craniosynostosis to date, highlighting the evolution of their technique.

Methods: The authors retrospectively reviewed patients who underwent endoscopic coronal suturectomy and SMC between 2017 and 2023.

View Article and Find Full Text PDF

Background: Congenital accessory auricle is a common aurcile malformation, often associated with tragus malformation, impacting the appearance and psychology of patients. To optimize surgical treatments for congenital accessory auricle with tragus malformation, this article proposes a novel classification and explores surgical strategies.

Methods: This retrospective study included 120 patients with congenital accessory auricle and tragus malformation who underwent surgery between December 2019 and June 2024.

View Article and Find Full Text PDF

Auricular reconstruction is essential for restoring facial symmetry and achieving a well-contoured, natural-appearing ear. Traditional methods using autologous costal cartilage often delay reconstruction until around age 10, when sufficient rib cartilage is available, which can pose physical and psychological challenges for pediatric patients. Porous high-density polyethylene (PHDPE) implants offer significant advantages, including the ability to perform reconstruction earlier, reduced morbidity, improved ear definition, and the possibility of a single-stage outpatient procedure.

View Article and Find Full Text PDF

Finite Element Analysis of Mandibular Distraction Osteogenesis With a New Partially Bioabsorbable Distractor.

J Craniofac Surg

September 2025

Department of Craniomaxillofacial Surgery, Peking Union Medical College, Chinese Academy of Medical Sciences, Plastic Surgery Hospital, Beijing, China.

Objective: We designed a new distractor pairing a bioabsorbable upper fixing plate fixed by bioabsorbable screws with a traditional titanium distractor to simplify the second surgery removing the distractor after mandibular distraction osteogenesis. The present study aims to evaluate its biomechanical properties using finite element method.

Materials And Methods: Ten computer-aided designed models simulating mandibles of 5 patients under 2 working conditions, the instance of distraction and mastication, were produced.

View Article and Find Full Text PDF