Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: The softball pitch is a full-body motion, where efficient proximal to distal energy flow through the kinetic chain is said to reduce stress at the upper extremity. Although altered trunk kinematic parameters are associated with upper extremity pain in softball pitchers, further research is needed to determine whether differences exist in proximal energy flow between softball pitchers with and without pain.

Hypothesis/purpose: To examine pelvis and trunk energy flow during the acceleration phase of the pitch in collegiate softball pitchers with and without upper extremity pain. It was hypothesized that those with upper extremity pain would have less energy flowing into the proximal ends of the pelvis and trunk as well as less energy flowing out of the distal ends of the pelvis and trunk during the acceleration phase when compared with pitchers who did not have upper extremity pain.

Study Design: Descriptive laboratory study.

Methods: A total of 54 female National Collegiate Athletic Association Division I softball pitchers (age, 20.2 ± 2.0 years; height, 173.5 ± 6.9 cm; weight, 78.5 ± 11.5 kg) were assigned to pain (n = 17) and pain-free (n = 38) groups. Participants pitched 3 maximal effort rise-balls for a strike, and the average of the 3 trials was used for analysis. Kinematic data were collected at 100 Hz using an electromagnetic tracking system. A segment power analysis was performed to quantify energy flow for the pelvis and trunk. The Mann-Whitney test was used to compare pelvis and trunk energy flow during the acceleration phase of the pitch as well as pitch velocity between collegiate softball pitchers with and without upper extremity pain.

Results: No significant differences were found between pelvis and trunk energy flow during the acceleration phase or pitch velocity between collegiate softball pitchers with and without upper extremity pain (all values >.057).

Conclusion: Previous research determined that kinematic parameters differ between collegiate pitchers with and without upper extremity pain. However, the current study found no difference in pelvis and trunk energy flow or pitch velocity. Although altered kinematics in collegiate pitchers with upper extremity pain may serve as compensation patterns to maintain pitch velocity and proximal energy flow, future research is needed to confirm this postulation.

Clinical Relevance: The lack of energy flow differences between upper extremity pain groups suggests that pitchers may adapt their biomechanics to maintain trunk and pelvis energy flow patterns. Coaches, athletes, and clinicians should know that movement adaptations can allow for maintained performance levels but may result in the presence of pain that may manifest in other deleterious and injury-susceptible biomechanics.

Download full-text PDF

Source
http://dx.doi.org/10.1177/03635465221114476DOI Listing

Publication Analysis

Top Keywords

energy flow
44
upper extremity
44
pelvis trunk
32
extremity pain
32
softball pitchers
28
pitchers upper
28
trunk energy
20
collegiate softball
16
acceleration phase
16
pitch velocity
16

Similar Publications

Precise delivery of nanoliter-scale reagents is essential for high-throughput biochemical assays, yet existing platforms often lack real-time control and selective content fusion. Conventional methods rely on passive encapsulation or stochastic pairing, limiting both throughput and biochemical specificity. Here, we introduce an on-demand nanoliter delivery platform that seamlessly integrates electrical sensing, triggered droplet merging, and passive sorting in a single continuous flow.

View Article and Find Full Text PDF

Gaining a fundamental understanding of turbulent flows of dilute polymer solutions has been a challenging and outstanding problem for a long time. In this Letter, we examine homogeneous, isotropic polymeric turbulence at large Reynolds and Deborah numbers through direct numerical simulations. While at the largest scales at which the flow inertial turbulence exists, we find that the flow is fundamentally altered from Newtonian turbulence below the Kolmogorov scale.

View Article and Find Full Text PDF

Partonic collectivity is one of the necessary signatures for the formation of quark-gluon plasma in high-energy nuclear collisions. Number of constituent quarks (NCQ) scaling has been observed for hadron elliptic flow v_{2} in top energy nuclear collisions at the Relativistic Heavy Ion Collider and the LHC, and this has been theoretically suggested as strong evidence for partonic collectivity. In this Letter, a systematic analysis of v_{2} of π^{±}, K^{±}, K_{S}^{0}, p, and Λ in Au+Au collisions at sqrt[s_{NN}]=3.

View Article and Find Full Text PDF

Chemically Lithiated Poly(vinylidene difluoride) with In Situ Generated LiF Nanofiller as Hybrid Artificial Layer for Stable Lithium Metal Anodes.

Small

September 2025

Key Laboratory of Electrochemical Power Sources of Hubei Province, College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, China.

Hybrid artificial layer based on inorganic/polymer composite endows superior toughness and mechanical strength, which can achieve high stability of lithium metal anode. However, the large particle size and uneven distribution of inorganic fillers hinder the uniform flow of lithium ions across the membrane, making it difficult to achieve smooth lithium metal deposition/stripping. In this work, a chemical lithiation-induced defluorination strategy is proposed to engineer  poly(vinylidene difluoride) (PVDF)-based artificial layers, enabling in situ incorporation of highly dispersed LiF nanofiller within the polymer matrix and precise control over the LiF content.

View Article and Find Full Text PDF

Fluorescent proteins (FPs) are commonly used as reporters to examine intracellular genetic, molecular, and biochemical status. Flow cytometry is a powerful technique for accurate quantification of single-cell fluorescent levels. Here, we characterize green, red, and blue FPs for use in yeast .

View Article and Find Full Text PDF