98%
921
2 minutes
20
Rapid antigen detection (RAD) tests are commonly used for the diagnosis of SARS-CoV-2 infections. However, with the continuous emergence of new variants of concern (VOC), presenting various mutations potentially affecting the nucleocapsid protein, the analytical performances of these assays should be frequently reevaluated. One hundred and twenty samples were selected and tested with both RT-qPCR and six commercial RAD tests that are commonly sold in Belgian pharmacies. Of these, direct whole-genome sequencing identified the strains present in 116 samples, of which 70 were Delta and 46 were Omicron (BA.1 and BA.1.1 sub-lineages, respectively). The sensitivity across a wide range of Ct values (13.5 to 35.7; median = 21.3) ranged from 70.0% to 92.9% for Delta strains and from 69.6% to 78.3% for Omicron strains. When taking swabs with a low viral load (Ct > 25, corresponding to <4.9 log10 copies/mL), only the Roche RAD test showed acceptable performances for the Delta strains (80.0%), while poor performances were observed for the other RAD tests (20.0% to 40.0%). All the tested devices had poor performances for the Omicron samples with a low viral load (0.0% to 23.1%). The poor performances observed with low viral loads, particularly for the Omicron strain, is an important limitation of RAD tests, which is not sufficiently highlighted in the instructions for use of these devices.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9031584 | PMC |
http://dx.doi.org/10.3390/v14040654 | DOI Listing |
Chem Pharm Bull (Tokyo)
September 2025
Graduate School of Pharmaceutical Sciences, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan.
Antigen-binding proteins, such as nanobodies, modified with functional small molecules hold great potential for applications including imaging probes, drug conjugates, and localized catalysts. However, traditional chemical labeling methods that randomly target lysine or cysteine residues often produce heterogeneous conjugates with limited reproducibility. Conventional site-specific conjugation approaches, which typically modify only the N- or C-terminus, may also be insufficient to achieve the desired functionalities.
View Article and Find Full Text PDFActa Trop
September 2025
Department of Molecular Tropical Medicine and Genetics, Faculty of Tropical Medicine, Mahidol University, Bangkok 10400, Thailand; Mahidol-Oxford Tropical Medicine Research Unit, Faculty of Tropical Medicine, Mahidol University, Bangkok 10400, Thailand; Centre for Tropical Medicine and Global Health
Background: The increasing recognition of zoonotic malaria, particularly from Plasmodium species infecting non-human primates (NHP), poses significant diagnostic challenges. Performance of human malaria Rapid Diagnostic Tests (RDTs) has not been evaluated in simian malaria.
Methods: A total of 131 blood samples from NHP hosts with confirmed malaria were analyzed using 14 different commercially available RDTs, detecting the antigens P.
Poult Sci
August 2025
Graduate Institute of Biomedical Sciences, China Medical University, Taichung 404, Taiwan. Electronic address:
Chicken Leucocytozoonosis is a protozoan disease that affects the blood and tissues of chickens. High summer temperatures create optimal conditions for reproducing biting midges, the primary vectors for transmitting Leucocytozoon to chickens. In Taiwan, a subtropical region, the disease remains prevalent throughout the year, except in winter, leading to significant economic losses due to increased mortality and reduced egg production.
View Article and Find Full Text PDFMikrochim Acta
September 2025
National Research and Development Institute for Chemistry and Petrochemistry ICECHIM, 202 Splaiul Independentei Street, 060021, Bucharest, Romania.
Molecular recognition and determination of vascular cell adhesion molecule-1 (VCAM-1), interleukin-6 (IL-6), and natriuretic peptide C-type (NPPC) are essential for the early prognosis and diagnosis of cardiovascular diseases, especially in young obese populations. Highly sensitive and selective devices characterized by low Limits of quantification are required for their determination in whole blood. Therefore, a 3D stochastic sensor was developed by immobilizing a chitosan hydrogel onto a carbon paste electrode (used as the support matrix for the hydrogel), which was subsequently modified with gold nanoparticles, multi-walled carbon nanotubes, and β-cyclodextrin (β-CD/AuNPs@MWCNT/CS/CPE).
View Article and Find Full Text PDFDiagn Microbiol Infect Dis
August 2025
Blood Center of Zhejiang Province, Hangzhou 310006, China.
This study analyzed the correlation between false-positive HIV ELISA results (using Bio-Rad reagents) and SARS-COV-2 antibody levels in 301 unpaid apheresis platelet donors with prior infection or vaccination, enrolled from Zhejiang Blood Center between February 1 and May 31, 2023. Trends in both the HIV ELISA false-positive rate and SARS-COV-2 antibody levels were assessed. The false-positive rate rose in early 2023, peaking at 0.
View Article and Find Full Text PDF