Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Recent evidence supports the use of machine perfusion technologies (MP) for marginal liver grafts. Their effect on enhanced recovery, however, remains uncertain.

Objectives: To identify areas in which MP might contribute to an ERAS program and to provide expert panel recommendations.

Data Sources: Ovid MEDLINE, Embase, Scopus, Google Scholar, and Cochrane Central.

Methods: Systematic review and meta-analysis following PRISMA guidelines and recommendations using the GRADE approach. CRD42021237713 RESULTS: Both hypothermic (HMP) and normothermic (NMP) machine perfusion demonstrated significant benefits in preventing postreperfusion syndrome (PRS) (HMP OR .33, .15-.75 CI; NMP OR .51, .29-.90 CI) and early allograft dysfunction (EAD) (HMP OR .51, .35-.75 CI; NMP OR .66, .45-.97 CI), while shortening LOS (HMP MD -3.9; NMP MD -12.41). Only NMP showed a significant decrease in the length of ICU stay (L-ICU) (MD -7.07, -8.76; -5.38 CI), while only HMP diminishes the likelihood of major complications. Normothermic regional perfusion (NRP) reduces EAD (OR .52, .38-.70 CI) and primary nonfunction (PNF) (OR .51, .27-.98 CI) without effect on L-ICU and LOS.

Conclusions: The use of HMP decreases PRS and EAD, specifically for marginal grafts. This is supported by a shorter LOS and a lower rate of major postoperative complications (QOE; moderate | Recommendation; Strong). NMP reduces the incidence of PRS and EAD with associated shortening in L-ICU for both DBD and DCD grafts (QOE; moderate | Recommendation; High) This technology also shortens the length of hospital stay (QOE; low | Recommendation; Strong). NRP decreases the likelihood of EAD (QOE; moderate) and the risk of PNF (QOE; low) when compared to both DBD and SRR-DCD grafts preserved in SCS. (Recommendation; Strong).

Download full-text PDF

Source
http://dx.doi.org/10.1111/ctr.14638DOI Listing

Publication Analysis

Top Keywords

machine perfusion
12
qoe moderate
12
recommendation strong
12
systematic review
8
expert panel
8
prs ead
8
moderate recommendation
8
qoe low
8
hmp
6
nmp
6

Similar Publications

The global shortage of suitable donor kidneys is the primary challenge in kidney transplantation, and it is exacerbated by ageing donors with increased numbers of health issues. Improving organ assessment, preservation and conditioning could enhance organ utilization and patient outcomes. Hypothermic machine perfusion (HMP) is associated with better results than static cold storage by reducing delayed graft function and improving short-term graft survival, especially in kidneys recovered from marginal-quality donors.

View Article and Find Full Text PDF

Static cold storage (SCS) on ice has remained the gold standard preservation method for heart transplantation, and prolonged cold ischemia outside the typical 4-6 hour window is associated with an increased risk of primary graft dysfunction - a consequence attributed to ischemic damage and reperfusion injury. This, unfortunately limits the travel radius for donor heart procurement, a key factor that contributes to the overall shortage of donor organs. Recent research and clinical data have illustrated the validity of other preservation systems in preserving cardiac allografts, and many of these devices have shown promise in potentially prolonging the tolerated ischemic time beyond the accepted standard.

View Article and Find Full Text PDF

Cardioplegic Machine Perfusion of Hearts Donated after Circulatory Death.

J Cardiovasc Transl Res

September 2025

Department of Cardiac Surgery, University Hospital Halle (Saale), University of Halle, Ernst-Grube-Straße 40, 06120, Halle (Saale), Germany.

We compared the effects of ex-vivo machine perfusion (EVMP) of hearts donated after circulatory death (DCD) with the single-shot solutions HTK-N and Del Nido cardioplegia (DNC) on left-ventricular (LV) contractility and myocardial microcirculation. In a DCD pig model, hearts were maintained by EVMP with hypothermic, oxygenated HTK-N (DCD-HTK-N; N = 8) or DNC (DCD-DNC; N = 8) followed by reperfusion with blood, including assessment of contractility and microcirculation with Laser-Doppler-Flow (LDF). We performed transcriptomics using microarrays.

View Article and Find Full Text PDF

Ischemia time is a well-established determinant of liver transplant outcomes. Patient survival is substantially affected by prolonged warm (WIT) and cold ischemia time (CIT) of the graft during liver transplant. One component that may be a contributing factor to both WIT and CIT is back bench time (BBT).

View Article and Find Full Text PDF

Objective: This study aims to construct a multimodal radiomics model based on contrast-enhanced ultrasound (CEUS) radiomic features, combined with conventional ultrasonography (US) images and clinical data, to evaluate its diagnostic efficacy in differentiating benign and malignant thyroid nodules (TNs) classified as C-TIRADS 4, and to assess the clinical application value of the model.

Methods: This retrospective study enrolled 135 patients with C-TIRADS 4 thyroid nodules who underwent concurrent US and CEUS before FNA/surgery. From each case, one US image and three CEUS key frames (2s post-perfusion, peak enhancement, 2s post-peak) were selected.

View Article and Find Full Text PDF