Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Coaxial electrohydrodynamic jet (CE-Jet) printing is an encouraging method for fabrication of high-resolution micro and nanostructures in MEMS systems. This paper presents a novel simulation work based on phase field method which is considered as a precise technique in fluid dynamics. The study explores influence of various parameters such as applied voltage, needle-substrate distance, dynamic viscosity, relative permittivity, needle size and flow rate on stability and resolution of CE-Jet morphologies. The morphology of CE-Jet exhibits that width of cone-jet profile and printed structures on substrate were directly proportional to relative permittivity and flow rate. In addition, it was inversely proportional to dynamic viscosity and applied voltage. The study examine that CE-Jet length of inner liquid is inversely proportional to needle-substrate distance in same time. It was later verified in experimental study by producing stable CE-Jet morphology with 300 μm diameter using optimized parameters (i.e., DC voltage 7.0 kV and inner liquid flow rate 400 nl/min) as compared to other validation studies such as 400 μm and 500 μm. The CE-Jet printing technique investigates significant changes in consistency and stability of CE-Jet morphologies and makes Jet unique and comparable when adjustment accuracy reaches 0.01 mm. PZT sol line structures with a diameter of 1 µm were printed directly on substrate using inner needle (diameter of 120 µm). Therefore, it is considered as a powerful tool for nano constructs production in M/NEMS devices.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8816925PMC
http://dx.doi.org/10.1038/s41598-022-05596-yDOI Listing

Publication Analysis

Top Keywords

flow rate
12
coaxial electrohydrodynamic
8
electrohydrodynamic jet
8
ce-jet printing
8
applied voltage
8
needle-substrate distance
8
dynamic viscosity
8
relative permittivity
8
ce-jet morphologies
8
inversely proportional
8

Similar Publications

Purpose: This study sought to determine the intrasession repeatability of the diffusion-weighted (DW) arterial spin labeling (ASL) sequence at different postlabel delays (PLDs).

Methods: We first performed numerical simulations to study the accuracy of the two-compartment water exchange rate (Kw) fitting model with added Gaussian noise for DW PLDs at 1500, 1800, and 2100 ms. Ten young, healthy participants then underwent a structural T scan and two intrasession in vivo DW ASL scans at each PLD on a 3T MRI.

View Article and Find Full Text PDF

A cross-scale analysis for the determinants of bonding dynamics on the distributions of rolling velocities of cells in microvessels.

Biophys J

September 2025

Key Laboratory of Hydrodynamics (Ministry of Education), Department of Engineering Mechanics, School of Ocean and Civil Engineering, Shanghai Jiao Tong University, Shanghai 200240, China. Electronic address:

The interplay between subcellular adhesion dynamics and cellular-scale deformations under shear flow drives key physiological and pathological processes. While both bond kinetics and fluid-cell interactions have been extensively studied in rolling adhesion, how bond characteristics quantitatively determine cellular velocity distributions remains unclear. In this study, we systematically investigate how force-free bond kinetics and intrinsic mechanical properties govern rolling adhesion dynamics, using macroscopic velocity distributions as a reference.

View Article and Find Full Text PDF

Background: Space exploration has progressed significantly, with increased human presence in orbit, the development of space stations, and the planning of increasingly prolonged missions. However, the space environment poses substantial physiological challenges, particularly for the cardiovascular system. According to NASA's Human Research Program, the five primary risks associated with human spaceflight are: (1) microgravity, (2) ionizing cosmic radiation, (3) isolation and confinement, (4) closed environmental systems, and (5) the great distance from Earth.

View Article and Find Full Text PDF

Purpose: Tracer kinetic models are used in arterial spin labeling (ASL); however, deciding which model parameters to fix or fit is not always trivial. The identifiability of the resultant system of equations is useful to consider, since it will likely impact parameter uncertainty. Here, we analyze the identifiability of two-compartment models used in multi-echo (ME) blood-brain-barrier (BBB)-ASL and evaluate the reliability of the fitted water-transfer rate ).

View Article and Find Full Text PDF

The present investigation sought to determine the cardiovascular responses to a commercially available KAATSU cuff system with rhythmic cuff inflation-deflation periods during leg exercise. Seventeen participants performed two-legged knee flexion/extension exercise at 25% of peak work rate (WR) with bilateral KAATSU cuffs applied to the proximal thigh (KAATSU) or work-rate matched control exercise (CTL). During KAATSU trials, the cuffs were set to Cycle Mode (repeated 30-s inflation; 5-s deflation) at progressively increasing cuff pressure (150-220 mmHg).

View Article and Find Full Text PDF