98%
921
2 minutes
20
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00384-021-04051-0 | DOI Listing |
J Neuroeng Rehabil
September 2025
Department of Kinesiology, Brock University, St. Catharines, ON, Canada.
Knee Surg Sports Traumatol Arthrosc
September 2025
Çankaya Hospital for Orthopedic Care, Ankara, Turkey.
Purpose: The aim of this study was to evaluate the impact of reduced spinopelvic mobility (SM) on knee flexion deformity (KFD) in patients undergoing total knee arthroplasty (TKA).
Methods: A retrospective analysis on 213 patients (271 knees) undergoing robotic-assisted primary TKA was conducted. Sagittal spinopelvic alignment (SSA) parameters-sacral slope (SS), pelvic incidence (PI), and pelvic tilt (PT)-were measured on lateral standing and sitting spinopelvic radiographs.
J Am Acad Orthop Surg
September 2025
From the Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY (Neitzke, O'Donnell, Buchalter, Chandi, Westrich, and Gausden), the Department of Orthopedic Surgery, University of Wisconsin-Madison, Madison, WI (O'Donnell), and Somers Orthopaedic Surgery & Sports Medicine Group
Introduction: Developmental dysplasia of the hip (DDH) poses challenges for component positioning during total hip arthroplasty (THA) secondary to abnormal bone morphology, soft-tissue contractures, and hip center migration. The objective of this study was to evaluate the radiographic and clinical outcomes of THA for DDH performed with robotic assistance versus manual (M) technique.
Methods: A retrospective review identified 115 patients with Crowe II to IV dysplasia undergoing primary THA at a single institution from 2016 to 2022.
Ann Surg Oncol
September 2025
Department of Surgery, Tokushima University, Tokushima, Japan.
Background: Although magnification is an advantage of robotic liver resection (RLR) as it enables precise surgery, the direction of parenchymal dissection, the vascular anatomy, and the tumor location can sometimes be lost. Extended reality (XR) has advantages over other navigation systems in terms of spatial awareness, sharing, and simplicity, and it also has the potential to overcome some of the limitations of RLR. METHODS: In this video, we demonstrate innovative RLR with XR by three separate surgeons.
View Article and Find Full Text PDFJ Appl Physiol (1985)
September 2025
Department of Neuroscience, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
This study aimed to characterize motor noise in human standing balance and uncover mechanisms that enable the nervous system to robustly sense and control upright posture despite this variability. We conducted three experiments using a robotic balance simulator. First, we quantified the natural variability of ankle torques, revealing that torque variability was stable within preferred postures and increased only at more extreme orientations.
View Article and Find Full Text PDF