Surface topography as a tool to detect early changes in a posttraumatic equine model of osteoarthritis.

J Orthop Res

Department of Clinical Sciences, Orthopaedic Research Center & C. Wayne McIlwraith Translational Medicine Institute, Colorado State University, Fort Collins, Colorado, USA.

Published: June 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The equine model of posttraumatic osteoarthritis (OA) mimics certain aspects of the naturally occurring disease, both in horses and humans. The objective of this study was to assess articular cartilage degeneration in a posttraumatic OA model using the established macroscopic and microscopic scoring systems and compare them with a novel surface topography analysis. OA was induced in the carpal joint of 15 (n = 15) mixed breed horses. Surface changes on the articular cartilage were characterized using osteochondral blocks from the third carpal bone (C3) and radial carpal bone using surface topography, standard histological grading, and gross evaluation of the joints. Significant differences were observed between OA and non-OA joints for gross evaluation scores. Microscopic scores of hematoxylin and eosin and Safranin O and Fast Green-stained sections demonstrated no differences between OA and non-OA joints. However, articular cartilage from the induced OA joint had significantly greater surface topography measurements compared with the sham treatment group, consistent with the changes seen on gross evaluation of joints. No significant correlations were noted between surface roughness measurements, histological assessment, and gross evaluation scores. The results suggest that surface topography analysis may provide a reliable objective approach to assess early changes in the cartilage surface in OA.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jor.25175DOI Listing

Publication Analysis

Top Keywords

surface topography
20
gross evaluation
16
articular cartilage
12
surface
8
early changes
8
equine model
8
topography analysis
8
evaluation joints
8
non-oa joints
8
evaluation scores
8

Similar Publications

In vitro assessment of the inhibitory effect of antiplatelet drugs on platelet aggregation is frequently employed to guide personalized antiplatelet therapy in clinical practice. However, existing methods for detecting platelet aggregation rely heavily on high concentrations of exogenous agonists, which may obscure part of the inhibitory effect of antiplatelet drugs and lead to an underestimation of their effects. This study validates a novel analytical strategy for evaluating the effects of antiplatelet drugs by quantifying the microscopic three-dimensional morphological parameters of platelet aggregates formed through spontaneous aggregation on a glass surface.

View Article and Find Full Text PDF

Hierarchical nanotopographies and fractal fingerprints of Anopheles mosquito wing surfaces.

Micron

September 2025

Laboratório de Desenvolvimento e Aplicações de Nanomateriais da Amazônia (LADENA), Departamento de Física de Materiais, Universidade Federal do Amazonas, Manaus, AM 69067-005, Brazil. Electronic address:

This study investigates the nanoscale surface morphology of Anopheles darlingi and Anopheles aquasalis mosquito wings using Atomic Force Microscopy (AFM) and fractal analysis. High-resolution 3D AFM imaging revealed pronounced inter- and intra-species differences, with the ventral surface of An. darlingi (V-Ad) exhibiting the greatest roughness (Sq = 45.

View Article and Find Full Text PDF

Scanning probe microscopy (SPM) is a powerful technique for mapping nanoscale surface properties through tip-sample interactions. Thermal scanning-probe lithography (tSPL) is an advanced SPM variant that uses a silicon tip on a heated cantilever to sculpt and measure the topography of polymer films with nanometer precision. The surfaces produced by tSPL-smooth topographic landscapes-allow mathematically defined contours to be fabricated on the nanoscale, enabling sophisticated functionalities for photonic, electronic, chemical and biological technologies.

View Article and Find Full Text PDF

Tactile sensors are crucial in robotics and medical diagnostics, requiring precise real-time detection. However, the development of a compact sensor that can measure force across a wide range, with high resolution and rapid response along three axes, remains extremely limited. Herein, an opto-electro-mechanical tactile sensor is reported, utilizing a monolithically integrated GaN-based optochip with a fingerprint-patterned polydimethylsiloxane (PDMS) film.

View Article and Find Full Text PDF

Background: Chikungunya virus (CHIKV) is an arbovirus with a significant global public health burden. Delineating the specific contributions of individual behaviour, household, natural and built environment to CHIKV transmission is important for reducing risk in urban informal settlements but challenging due to their heterogeneous environments. The aim of this study was to quantify variation in CHIKV seroprevalence between and within four urban communities in a large Brazilian city, and identify the respective contributions of individual, household, and environmental factors for seropositivity.

View Article and Find Full Text PDF