Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: The 2020 Global Vascular Guidelines aim at improving decision making in Chronic Limb-Threatening Ischemia (CLTI) by providing a framework for evidence-based revascularization. Herein, the Global Limb Anatomic Staging System (GLASS) serves to estimate the chance of success and patency of arterial pathway revascularization based on the extent and distribution of the atherosclerotic lesions. We report the preliminary feasibility results and observer variability of the GLASS. GLASS is a part of the new global guideline and posed as a promising additional tool for EBR strategies to predict the success of lower extremity arterial revascularization. This study reports on the consistency of GLASS scoring to maximize inter-observer agreement and facilitate its application.

Methods: GLASS separately scores the femoropopliteal (FP) and infrapopliteal (IP) segment based on stenosis severity, lesion length and the extent of calcification within the target artery pathway (TAP). In our stepwise approach, we used two angiographic datasets. Each following step was based on the lessons learned from the previous step. The primary outcome was inter-observer agreement measured as Cohen's Kappa, scored by two (step 1 + 2) and four (step 3) blinded and experienced observers, respectively. Steps 1 ( = 139) and 2 ( = 50) were executed within a dataset of a Dutch interventional RCT in CLTI. Step 3 ( = 100) was performed in randomly selected all-comer CLTI patients from two vascular centers in the United States.

Results: In step 1, kappa values were 0.346 (FP) and 0.180 (IP). In step 2, applied in the same dataset, the use of other experienced observers and a provided TAP, resulted in similar low kappa values 0.406 (FP) and 0.089 (IP). Subsequently, in step 3, the formation of an altered stepwise approach using component scoring, such as separate scoring of calcification and adding a ruler to the images resulted in kappa values increasing to 0.796 (FP) and 0.730 (IP).

Conclusion: This retrospective GLASS validation study revealed low inter-observer agreement for unconditioned scoring. A stepwise component scoring provides acceptable agreement and a solid base for further prospective validation studies to investigate how GLASS relates to treatment outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8396876PMC
http://dx.doi.org/10.3390/jcm10163454DOI Listing

Publication Analysis

Top Keywords

inter-observer agreement
16
kappa values
12
global limb
8
limb anatomic
8
anatomic staging
8
staging system
8
glass
8
system glass
8
stepwise approach
8
step
8

Similar Publications

Objective: This study aims to systematically evaluate the inter- and intra-observer agreement regarding lesions with uncertain malignancy potential in Ga-68 PSMA PET/CT imaging of prostate cancer patients, utilizing the PSMA-RADS 2.0 classification system, and to emphasize the malignancy evidence associated with these lesions.

Methods: We retrospectively reviewed Ga-68 PSMA PET/CT images of patients diagnosed with prostate cancer via histopathology between December 2016 and November 2023.

View Article and Find Full Text PDF

Isolated Congenital Middle Ear Malformations: Comparison of preoperative 0.1 mm Ultra-High-Resolution CT and Conventional High-Resolution CT.

AJNR Am J Neuroradiol

September 2025

From the Department of Otorhinolaryngology Head and Neck Surgery (J.G., Y.L., S.G.) and Department of Radiology (N.X., R.T., H.D.,Z.Y., Z.W., P.Z.), Beijing Friendship Hospital, Capital Medical University, Beijing, China.

Background And Purpose: Isolated congenital middle ear malformation contributes significantly to congenital hearing loss and growth problems. This study aims to compare 0.1 mm isotropic ultra-high-resolution computed tomography and conventional high-resolution computed tomography for assessing isolated congenital middle ear malformation, using surgical exploration as the gold standard.

View Article and Find Full Text PDF

Renal Resistive Index (RRI) and Renal Pulsatility Index (RPI) are currently used in the diagnosis of ureteral obstruction, early diagnosis and follow-up of acute kidney injury, assessment of chronic kidney disease, and evaluation of transplanted kidneys. However, their inter-observer and inter-scanner variability has not been investigated in dogs, limiting the accuracy and clinical applicability of these indices. The objectives of this cross-sectional observational prospective study were to assess the inter-observer and inter-scanner variability of RRI and RPI and to determine whether operator experience influences measurement accuracy.

View Article and Find Full Text PDF

Background: A significant contributory factor to the brachycephalic obstructive airway syndrome index of bulldogs is the diameter of their tracheas. Bulldogs are predisposed to tracheal hypoplasia. A non-invasive, financially reasonable and widely accessible screening test for tracheal diameter would be useful for assessing the most appropriate dogs to breed from within bulldog populations and may help in predicting results following upper airway surgery.

View Article and Find Full Text PDF

Background: Low-field MRI provides superior soft-tissue contrast compared to CT while costing significantly less than high-field MRI, which makes it a more accessible option for MRI-guided radiation therapy planning. Four-dimensional MRI (4D-MRI) is a technique that has been increasingly adopted clinically for internal target volume (ITV) delineation in free-breathing liver radiotherapy planning, and it requires high spatial resolution and accurate respiratory phase differentiation to enable precise dose planning. The feasibility of 4D-MRI at low-field strength, specifically at 0.

View Article and Find Full Text PDF