98%
921
2 minutes
20
Purpose: Recently, a 3D-concentric ring trajectory (CRT)-based free induction decay (FID)-MRSI sequence was introduced for fast high-resolution metabolic imaging at 7 T. This technique provides metabolic ratio maps of almost the entire brain within clinically feasible scan times, but its robustness has not yet been thoroughly investigated. Therefore, we have assessed quantitative concentration estimates and their variability in healthy volunteers using this approach.
Methods: We acquired whole-brain 3D-CRT-FID-MRSI at 7 T in 15 min with 3.4 mm nominal isometric resolution in 24 volunteers (12 male, 12 female, mean age 27 ± 6 years). Concentration estimate maps were calculated for 15 metabolites using internal water referencing and evaluated in 55 different regions of interest (ROIs) in the brain. Data quality, mean metabolite concentrations, and their inter-subject coefficients of variation (CVs) were compared for all ROIs.
Results: Of 24 datasets, one was excluded due to motion artifacts. The concentrations of total choline, total creatine, glutamate, myo-inositol, and N-acetylaspartate in 44 regions were estimated within quality thresholds. Inter-subject CVs (mean over 44 ROIs/minimum/maximum) were 9%/5%/19% for total choline, 10%/6%/20% for total creatine, 11%/7%/24% for glutamate, 10%/6%/19% for myo-inositol, and 9%/6%/19% for N-acetylaspartate.
Discussion: We defined the performance of 3D-CRT-based FID-MRSI for metabolite concentration estimate mapping, showing which metabolites could be robustly quantified in which ROIs with which inter-subject CVs expected. However, the basal brain regions and lesser-signal metabolites in particular remain as a challenge due susceptibility effects from the proximity to nasal and auditory cavities. Further improvement in quantification and the mitigation of B /B -field inhomogeneities will be necessary to achieve reliable whole-brain coverage.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11475238 | PMC |
http://dx.doi.org/10.1002/nbm.4596 | DOI Listing |
Biotechniques
September 2025
Woman, Mother + Baby Research Institute, Tufts Medicine, Boston, MA, USA.
MicroRNAs (miRNAs) are considered more stable than mRNA, but the impact of progressive thawing of biological samples after freezing as may happen during shipping delays has not been quantified. To address this, we utilized digital PCR to estimate the absolute concentrations of select miRNAs following progressive thawing of human plasma and maintenance at ambient temperature. Specifically, we quantified let-7b-3p, miR-144-5p, miR-150-5p, miR-517a-3p, miR-524-5p, and miR-1283, which have varying abundance in plasma.
View Article and Find Full Text PDFEnviron Technol
September 2025
School of Architecture and Urban Planning, Chongqing Jiaotong University, Chongqing, People's Republic of China.
As urbanization accelerates, the issue of pollutant discharge from building materials has become the focus of public attention. Conducted in a ventilated environmental chamber, the experiments investigated the emission characteristics of VOCs from dry and wet building materials, focusing on the influencing factors, such as temperature, relative humidity (RH), ventilation, and seasonality. The impact of influencing factors was quantified using a one-factor-at-a-time control method.
View Article and Find Full Text PDFAnal Chim Acta
November 2025
The Associated Laboratory for Green Chemistry (LAQV) of the Network of Chemistry and Technology (REQUIMTE) - the Portuguese Research Centre for Sustainable Chemistry, Department of Chemical Sciences, Faculty of Pharmacy, University of Porto, 4050-313, Porto, Portugal. Electronic address:
Background: When using semiconductor quantum dots (QDs) for single-analyte sensing, recognition is commonly achieved through interactions with capping ligands attached to the QDs surface. These ligands form an organic layer that provides stability in solution and assures selectivity by binding the target analyte via surface functional groups. However, a common analytical challenge arises in the subsequent stage of the QD-based sensing scheme.
View Article and Find Full Text PDFAnal Chim Acta
November 2025
School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, 611731, PR China; Yangtze Delta Region Institute (Huzhou), University of Electronic Science and Technology of China, Huzhou, Zhejiang, 313001, PR China; Laboratory for Microwave Spatial Inte
Background: X-ray fluorescence (XRF) technology is a promising method for estimating the metal element content in ores, which helps in understanding ore composition and optimizing mining and processing strategies. However, due to the presence of a large number of redundant features in XRF spectra, traditional quantitative analysis models struggle to effectively capture the nonlinear relationship between element concentration and spectral information of XRF, making it more difficult to accurately predict metal element concentrations. Thus, analyzing ore element concentrations by XRF remains a significant challenge.
View Article and Find Full Text PDFJ Virol Methods
September 2025
Laboratorio de Virología, Facultad de Ciencias Veterinarias, Universidad Nacional de La Plata, Buenos Aires, Argentina. 60 y 118, La Plata (CP 1900), Buenos Aires, Argentina; Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz 2290, CABA, Argentina. Electronic address
The global emergence of SARS-CoV-2 has highlighted the need for rapid, sensitive, and affordable diagnostic tools, not only for human health but also for animal surveillance within a One Health framework. This study aimed to evaluate the performance of a SYBR Green-based real-time quantitative PCR (qPCR) assay for the detection of SARS-CoV-2 from animal samples, focusing on domestic dogs and cats. A total of 140 oropharyngeal swab samples were collected and analyzed using primers targeting a 139-bp fragment of the N gene of SARS-CoV-2.
View Article and Find Full Text PDF